Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 175

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Sensitivity of contrast enhanced MRI in multiple sclerosis. Effects of gadolinium dose, magnetization transfer contrast and delayed imaging

Silver, N.·1997·Brain

Abstract

Although clinical end points remain the definitive measure of therapeutic efficacy in multiple sclerosis, more sensitive markers of disease activity are required to screen potential disease-modifying agents. The use of gadolinium contrast-media in MRI studies increases both the reliability and sensitivity of detecting active lesions in multiple sclerosis. We studied three potential methods for further improving sensitivity; the use of 0.3 mmol/kg (triple dose) gadolinium-diethylenetriaminepenta-acetic acid (Gd-DTPA), magnetization transfer (MT) contrast imaging and the introduction of a delay between contrast-medium injection and imaging. Fifty patients were studied (seven with benign, 14 with relapsing-remitting, 10 with secondary progressive, 16 with primary progressive and three with transitional multiple sclerosis). Imaging was performed on two occasions, 24-72 h apart, with triple- and single-dose Gd-DTPA. Pairs of contrast-enhanced T 1-weighted studies, with and without MT, were obtained at three different times, i.e. within early (0-20 min), short-delay (20-40 min) and long-delay (40-60 min) time-windows. Nineteen patients did not have the full complement of studies. Seven patients suffered minor self-limiting adverse events possibly related to triple-dose Gd-DTPA. Overall, triple-dose Gd-DTPA resulted in a 75% increase in the number of enhancing lesions detected compared with the single dose (P < 0.002). The use of MT or delay alone did not significantly increase the sensitivity of either single- or triple-dose studies. The combination of MT and short delay increased the number of enhancing lesions detected with single-dose Gd-DTPA by 47% (P < 0.05) and with triple-dose Gd-DTPA by 27% (P < 0.01). Detection was not significantly further improved by a long delay. The most sensitive modality was MT imaging with a long delay following triple-dose Gd-DTPA, resulting in the detection of 126% more enhancing lesions than in standard single-dose imaging (P < 0.05). This applies to all subgroups except for primary progressive multiple sclerosis, in which none of these methods alone or in combination improved the sensitivity. We conclude that for relapsing-remitting and secondary progressive multiple sclerosis, the combination of triple-dose Gd-DTPA and delayed MT imaging more than doubles the sensitivity to contrast-enhancing lesions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/brain/120.7.1149

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 175

Metadata

Authors
Silver, N.
Venue
Brain
Published
1997-07-01
Volume
120
Issue
7
Pages
1149-1161
ISSN
  • 0006-8950 (ISSN-L)
  • 1460-2156
OpenAlex
W2150787884
Cited by
175
References
2
FWCI
10.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sensitivity of contrast enhanced MRI in multiple sclerosis. Effects of gadolinium dose, magnetization transfer contrast and delayed imaging. https://app.cochat.ai/papers/10.1093/brain/120.7.1149
The paper
Silver, N. (1997). Sensitivity of contrast enhanced MRI in multiple sclerosis. Effects of gadolinium dose, magnetization transfer contrast and delayed imaging. Brain. https://doi.org/10.1093/brain/120.7.1149

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.