The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
An investigation of the retinal nerve fibre layer in progressive multiple sclerosis using optical coherence tomography
Abstract
Axonal loss is thought to be the predominant cause of disability in progressive multiple sclerosis (MS). The retinal nerve fibre layer (RNFL) is composed largely of unmyelinated axons of retinal ganglion cells, and is accessible to study with optical coherence tomography (OCT), giving a measure of axonal loss. OCT measures of the RNFL thickness (RNFLT) and macular volume were studied in 23 patients with primary progressive multiple sclerosis (primary progressive MS) (13 male; 10 female; mean age 52 years; median EDSS 6.0; mean disease duration 11 years), and 27 patients with secondary progressive multiple sclerosis (secondary progressive MS) (8 male; 19 female; mean age 50 years; median EDSS 6; mean disease duration 22 years). Of the patients with secondary progressive MS, 14 had clinical history of optic neuritis (ON) in a single eye; the remaining patients had not had ON. Twenty healthy controls (11 male; 9 female; mean age 46 years) had RNFLT and macular volume studied. Of the patients' eyes not previously affected by ON, both the mean RNFL thickness and macular volume were reduced when compared with control values. The mean RNFL thickness and macular volume were significantly reduced in secondary progressive MS, but not in primary progressive MS when compared with control RNFL thickness and macular volume. RNFL loss was most evident in the temporal quadrant, where significant reduction was seen in primary progressive MS versus controls and in secondary versus primary progressive MS. There were significant correlations of decreased RNFLT and macular volume with measures of visual acuity, low contrast visual acuity and visual field mean deviation in the MS patients. There are significant global reductions in RNFLT and macular volume in the eyes of secondary progressive MS patients not previously affected by ON, but not in primary progressive MS patients, compared with controls. This may indicate a difference in the extent of the pathological processes that cause axonal loss in the retina, and by inference the optic nerve, in secondary progressive MS and primary progressive MS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rating neurologic impairment in multiple sclerosis: An expanded disability status scale (EDSS)
Kurtzke, J. F. (1983) · Neurology · doi:10.1212/wnl.33.11.1444 · Cited by 15,011
Diagnostic criteria for multiple sclerosis: 2005 revisions to the “McDonald Criteria”
Polman, C. H., Reingold, S. C., Edan, G., Filippi, M., Hartung, H., Kappos, L., Lublin, F. D., Metz, L. M., McFarland, H. F., O'Connor, P. W., et al. (2005) · Annals of Neurology · doi:10.1002/ana.20703 · Cited by 5,017
Axonal transection in the lesions of multiple sclerosis
Trapp, B. D., Peterson, J., Ransohoff, R. M., Rudick, R., Mörk, S., & Bö, L. (1998) · New England Journal of Medicine · doi:10.1056/nejm199801293380502 · Cited by 4,029
Cited by
The retina as a window to the brain—from eye research to CNS disorders
London, A., Benhar, I., & Schwartz, M. (2013) · Nature Reviews Neurology · doi:10.1038/nrneurol.2012.227 · Cited by 1,403
Toosy, A. T., Mason, D. F., & Miller, D. H. (2014) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70259-x · Cited by 617
Self-citationOptical coherence tomography in multiple sclerosis: a systematic review and meta-analysis
Petzold, A., de Boer, J. F., Schippling, S., Vermersch, P., Kardon, R., Green, A., Calabresi, P. A., & Polman, C. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70168-x · Cited by 596
Green, A. J., McQuaid, S., Hauser, S. L., Allen, I. V., & Lyness, R. (2010) · Brain · doi:10.1093/brain/awq080 · Cited by 487
Longitudinal study of vision and retinal nerve fiber layer thickness in multiple sclerosis
Talman, L. S., Bisker, E. R., Sackel, D. J., Long, D. A., Galetta, K. M., Ratchford, J. N., Lile, D. J., Farrell, S. K., Loguidice, M. J., Remington, G., et al. (2010) · Annals of Neurology · doi:10.1002/ana.22005 · Cited by 366
Metadata
- Authors
- Henderson, A. P. D., Trip, S. A., Schlottmann, P. G., Altmann, D. R., Garway-Heath, D. F., Plant, G. T., & Miller, D. H.
- Venue
- Brain
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-12-04
- Volume
- 131
- Issue
- Pt 1
- Pages
- 277-87
- ISSN
- 0006-8950 (ISSN-L)
- 1460-2156
- OpenAlex
- W2158535248
- Cited by
- 239
- References
- 3
- FWCI
- 11.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An investigation of the retinal nerve fibre layer in progressive multiple sclerosis using optical coherence tomography. https://app.cochat.ai/papers/10.1093/brain/awm285
- The paper
- Henderson, A. P. D., Trip, S. A., Schlottmann, P. G., Altmann, D. R., Garway-Heath, D. F., Plant, G. T., & Miller, D. H. (2007). An investigation of the retinal nerve fibre layer in progressive multiple sclerosis using optical coherence tomography. Brain. https://doi.org/10.1093/brain/awm285
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.