Sensitivity of MEG and EEG to Source Orientation
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
An important difference between magnetoencephalography (MEG) and electroencephalography (EEG) is that MEG is insensitive to radially oriented sources. We quantified computationally the dependency of MEG and EEG on the source orientation using a forward model with realistic tissue boundaries. Similar to the simpler case of a spherical head model, in which MEG cannot see radial sources at all, for most cortical locations there was a source orientation to which MEG was insensitive. The median value for the ratio of the signal magnitude for the source orientation of the lowest and the highest sensitivity was 0.06 for MEG and 0.63 for EEG. The difference in the sensitivity to the source orientation is expected to contribute to systematic differences in the signal-to-noise ratio between MEG and EEG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“Sources in the region of the SMA with a close to perpendicular cortical (dipole) orientation to the skull electrodes may be more readily detected by MEG than EEG (Ahlfors et al., 2010).”
From Oscillating central motor networks in pathological tremors and voluntary movements. What makes the difference? (2012) · cites this paper as Ahlfors et al., 2010
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This difference may be due to the use of MEG recordings in previous studies, and MEG may be more sensitive to cortical sources than EEG.”
From Oscillating central motor networks in pathological tremors and voluntary movements. What makes the difference? (2012) · cites this paper as Ahlfors et al., 2010
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“However, previous studies were all MEG-based, which may be slightly inferior to EEG in detecting deep radial sources (Ahlfors et al., 2010)”
From Oscillating central motor networks in pathological tremors and voluntary movements. What makes the difference? (2012) · cites this paper as Ahlfors et al., 2010
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910 · cited 1×
“A surface mesh of the gray-white matter border of the cerebral cortex with about 300 000 vertices was constructed from the MRI using the Free Surfer software (Dale et al. 1999; Fischl et al. 1999).”
MethodCortical Surface-Based Analysis
Fischl, B., Sereno, M. I., & Dale, A. M. (1999) · NeuroImage · doi:10.1006/nimg.1998.0396 · Cited by 6,147 · cited 1×
“A surface mesh of the gray-white matter border of the cerebral cortex with about 300 000 vertices was constructed from the MRI using the Free Surfer software (Dale et al. 1999; Fischl et al. 1999).”
MethodHämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 2×
“One of the main differences between magnetoencephalography (MEG) and electroencephalography (EEG) is thought to be that MEG is mainly sensitive to tangentially oriented sources, whereas EEG can detect sources of all orientations (Baillet et al. 2001; Cohen and Cuffin 1991; Hämäläinen et al. 1993).”
BackgroundSelf-citationBaillet, S., Mosher, J. C., & Leahy, R. M. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962275 · Cited by 1,692 · cited 2×
“One of the main differences between magnetoencephalography (MEG) and electroencephalography (EEG) is thought to be that MEG is mainly sensitive to tangentially oriented sources, whereas EEG can detect sources of all orientations (Baillet et al. 2001; Cohen and Cuffin 1991; Hämäläinen et al. 1993).”
BackgroundGeddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610 · cited 2×
“The conductivity ratios of 1:0.0125:1 were assumed for brain:skull:scalp ( Geddes and Baker 1967 ).”
BackgroundInfluentialRealistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989 · cited 4×
“…accordance with those found in previous studies comparing dipole localization accuracy in spherically symmetric volume conductor model vs. anatomically more realistic head models (Hämäläinen and Sarvas 1989; Haueisen et al. 2002; Schimpf et al. 2002; Tarkiainen et al. 2003; Wolters et al. 2006).”
BackgroundMethodResultInfluentialEEG and MEG: forward solutions for inverse methods
Mosher, J. C., Leahy, R. M., & Lewis, P. S. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.748978 · Cited by 839 · cited 2×
“Silent source elements are a special case of silent source distributions defined by the null space of the forward matrix (Mosher et al. 1999; Riera et al. 2006).”
BackgroundMethodA sensor-weighted overlapping-sphere head model and exhaustive head model comparison for MEG
Huang, M. X., Mosher, J. C., & Leahy, R. M. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/2/010 · Cited by 612 · cited 2×
“…guarantee that the spherical model will provide an accurate MEG forward solution for those locations, previous studies have suggested that often the spherical model does indeed provide an accurate forward model for MEG, especially for most of the superficial cortical regions (Huang et al. 1999).”
BackgroundMethodWolters, C. H., Anwander, A., Tricoche, X., Weinstein, D., Koch, M. A., & MacLeod, R. S. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.10.014 · Cited by 452 · cited 4×
“…accordance with those found in previous studies comparing dipole localization accuracy in spherically symmetric volume conductor model vs. anatomically more realistic head models (Hämäläinen and Sarvas 1989; Haueisen et al. 2002; Schimpf et al. 2002; Tarkiainen et al. 2003; Wolters et al. 2006).”
MethodResultInfluentialA Quantitative Assessment of the Sensitivity of Whole-Head MEG to Activity in the Adult Human Cortex
Hillebrand, A., & Barnes, G. R. (2002) · NeuroImage · doi:10.1006/nimg.2002.1102 · Cited by 428 · cited 2×
“Few cortical sources, however, are expected to have exactly the orientation of the lowest sensitivity in MEG (Hillebrand and Barnes 2002).”
Background
Cited by
EEG and MEG: Relevance to Neuroscience
Lopes da Silva, F. (2013) · Neuron · doi:10.1016/j.neuron.2013.10.017 · Cited by 900
“Theoretically, a radially oriented dipolar source does not give rise to a magnetic field outside a spherical volume conductor; consequently the MEG is not sensitive to radial components of dipolar sources but to the tangential components (Ahlfors et al., 2010).”
Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients
Brodbeck, V., Spinelli, L., Lascano, A. M., Wissmeier, M., Vargas, M.-I., Vulliemoz, S., Pollo, C., Schaller, K., Michel, C. M., & Seeck, M. (2011) · Brain · doi:10.1093/brain/awr243 · Cited by 427
“There are concerns that MEG may miss deep sources and that it is insensitive to sources with radial orientation (Ahlfors et al., 2010), which appears to be less of an issue in EEG (Lejten et al.”
BackgroundRoux, F., Wibral, M., Singer, W., Aru, J., & Uhlhaas, P. J. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.5778-12.2013 · Cited by 169
Muthuraman, M., Heute, U., Arning, K., Anwar, A. R., Elble, R., Deuschl, G., & Raethjen, J. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.088 · Cited by 134
“However, previous studies were all MEG-based, which may be slightly inferior to EEG in detecting deep radial sources (Ahlfors et al., 2010), and these studies did not establish the tremor network with respect to the rhythmic EMG signal but to the cortical region with the strongest coherence with EMG (typically M1).”
Babo-Rebelo, M., Wolpert, N., Adam, C., Hasboun, D., & Tallon-Baudry, C. (2016) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2016.0004 · Cited by 106
Metadata
- Authors
- Ahlfors, S. P., Han, J., Belliveau, J. W., & Hämäläinen, M. S.
- Affiliations
- Harvard University (US)
- Corresponding author
- Ahlfors, Seppo P.
- Venue
- Brain Topography
- Published
- 2010-07-18
- Volume
- 23
- Issue
- 3
- Pages
- 227-232
- ISSN
- 0896-0267 (ISSN-L)
- 1573-6792
- PMC
- PMC2914866
- OpenAlex
- W1565410510
- Semantic Scholar
- 061ed32cfd3870a9eedaa09036dc1811843b7af3
- Cited by
- 1
- References
- 37
- Citations by year
- 2023: 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc
- Locations
- Brain Topography (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc)
- Springer US
- Funders
- National Institutes of Health (NS037462)
- National Institute of Neurological Disorders and Stroke (R01NS057500, R56NS057500, -NS037462, R01NS037462, NS057500, R56NS037462)
- National Center for Research Resources (P41RR014075)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (HD 040712, R01HD040712)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- magnetoencephalography, EEG, source orientation, realistic head model, forward model, signal-to-noise ratio, cortical sources
- MeSH terms
- Adult, Brain Mapping, Cerebral Cortex, Electroencephalography, Humans, Male, Models, Neurological, Orientation, Sensitivity and Specificity, Signal Processing, Computer-Assisted, Magnetoencephalography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensitivity of MEG and EEG to Source Orientation. https://app.cochat.ai/papers/10.1007/s10548-010-0154-x
- The paper
- Ahlfors, S. P., Han, J., Belliveau, J. W., & Hämäläinen, M. S. (2010). Sensitivity of MEG and EEG to Source Orientation. Brain Topography. https://doi.org/10.1007/s10548-010-0154-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.