Magnetoencephalography for epileptic focus localization in a series of 1000 cases
The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
The aim of epilepsy surgery in patients with focal, pharmacoresistant epilepsies is to remove the complete epileptogenic zone to achieve long-term seizure freedom. In addition to a spectrum of diagnostic methods, magnetoencephalography focus localization is used for planning of epilepsy surgery. We present results from a retrospective observational cohort study of 1000 patients, evaluated using magnetoencephalography at the University Hospital Erlangen over the time span of 28 years. One thousand consecutive cases were included in the study, evaluated at the University Hospital Erlangen between 1990 and 2018. All patients underwent magnetoencephalography as part of clinical workup for epilepsy surgery. Of these, 405 underwent epilepsy surgery after magnetoencephalography, with postsurgical follow-ups of up to 20 years. Sensitivity for interictal epileptic activity was evaluated, in addition to concordance of localization with the consensus of presurgical workup on a lobar level. We evaluate magnetoencephalography characteristics of patients who underwent epilepsy surgery versus patients who did not proceed to surgery. In operated patients, resection of magnetoencephalography localizations were related to postsurgical seizure outcomes, including long-term results after several years. In comparison, association of lesionectomy with seizure outcomes was analysed. Measures of diagnostic accuracy were calculated for magnetoencephalography resection and lesionectomy. Sensitivity for interictal epileptic activity was 72% with significant differences between temporal and extra-temporal lobe epilepsy. Magnetoencephalography was concordant with the presurgical consensus in 51% and showed additional or more focal involvement in an additional 32%. Patients who proceeded to surgery showed a significantly higher percentage of monofocal magnetoencephalography results. Complete magnetoencephalography resection was associated with significantly higher chances to achieve seizure freedom in the short and long-term. Diagnostic accuracy was significant in temporal and extra-temporal lobe cases, but was significantly higher in extra-temporal lobe epilepsy (diagnostic odds ratios of 4.4 and 41.6). Odds ratios were also higher in non-lesional versus lesional cases (42.0 versus 6.2). The results show that magnetoencephalography provides non-redundant information, which significantly contributes to patient selection, focus localization and ultimately long-term seizure freedom after epilepsy surgery. Specifically in extra-temporal lobe epilepsy and non-lesional cases, magnetoencephalography provides excellent accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kwan, P., Arzimanoglou, A., Berg, A. T., Brodie, M. J., Allen Hauser, W., Mathern, G., Moshé, S. L., Perucca, E., Wiebe, S., & French, J. (2010) · Epilepsia · doi:10.1111/j.1528-1167.2009.02397.x · Cited by 4,877
Surgical Treatment of the Epilepsies
Kotagal, P. (1994) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199407000-00009 · Cited by 2,747
Histopathological Findings in Brain Tissue Obtained during Epilepsy Surgery
Blumcke, I., Spreafico, R., Haaker, G., Coras, R., Kobow, K., Bien, C. G., Pfäfflin, M., Elger, C., Widman, G., Schramm, J., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1703784 · Cited by 931
Self-citationPatterns of treatment response in newly diagnosed epilepsy
Brodie, M. J., Barry, S. J. E., Bamagous, G. A., Norrie, J. D., & Kwan, P. (2012) · Neurology · doi:10.1212/wnl.0b013e3182563b19 · Cited by 931
de Tisi, J., Bell, G. S., Peacock, J. L., McEvoy, A. W., Harkness, W. F., Sander, J. W., & Duncan, J. S. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60890-8 · Cited by 887
Magnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents
Cohen, D. (1968) · Science · doi:10.1126/science.161.3843.784 · Cited by 750
Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients
Brodbeck, V., Spinelli, L., Lascano, A. M., Wissmeier, M., Vargas, M.-I., Vulliemoz, S., Pollo, C., Schaller, K., Michel, C. M., & Seeck, M. (2011) · Brain · doi:10.1093/brain/awr243 · Cited by 427
Taylor, R. S., Sander, J. W., Taylor, R. J., & Baker, G. A. (2011) · Epilepsia · doi:10.1111/j.1528-1167.2011.03213.x · Cited by 393
Magnetic brain source imaging of focal epileptic activity: a synopsis of 455 cases
Stefan, H. (2003) · Brain · doi:10.1093/brain/awg239 · Cited by 304
Self-citationA guideline for head volume conductor modeling in EEG and MEG
Vorwerk, J., Cho, J.-H., Rampp, S., Hamer, H., Knösche, T. R., & Wolters, C. H. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.06.040 · Cited by 302
Self-citation
Cited by
Feys, O., Corvilain, P., Aeby, A., Sculier, C., Holmes, N., Brookes, M., Goldman, S., Wens, V., & De Tiège, X. (2022) · Radiology · doi:10.1148/radiol.212453 · Cited by 144
“OPM-MEG recording (15 OPMs with a bespoke three-dimensional-printed scanner cast that housed the OPMs) has been described in one adult patient with RFE (6).”
BackgroundInfluentialHolmes, N., Rea, M., Hill, R. M., Leggett, J., Edwards, L. J., Hobson, P. J., Boto, E., Tierney, T. M., Rier, L., Rivero, G. R., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120157 · Cited by 89
Metadata
- Authors
- Rampp, S., Stefan, H., Wu, X., Kaltenhäuser, M., Maess, B., Schmitt, F. C., Wolters, C. H., Hamer, H., Kasper, B. S., Schwab, S., Doerfler, A., Blümcke, I., Rössler, K., & Buchfelder, M.
- Venue
- Brain
- Publisher
- Oxford University Press (OUP)
- Published
- 2019-08-02
- Volume
- 142
- Issue
- 10
- Pages
- 3059-3071
- ISSN
- 0006-8950 (ISSN-L)
- 1460-2156
- OpenAlex
- W2972910435
- Cited by
- 163
- References
- 45
- FWCI
- 12.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.