A New Procedure for the Specific High-Performance Liquid Chromatographic Determination of Hydroxyproline
The DOI matches its Crossref record.
Abstract
A procedure suitable for a selective high-performance liquid chromatographic (HPLC) analysis of the imino acid hydroxyproline in the presence of a large excess of amino acids is proposed. To deaminate the amino acids, the well-known reaction with nitrous acid is exploited. The N-nitroso derivatives of imino acids obtained are extracted in ethyl acetate, denitrosated by hydrobromic acid, and treated with dabsyl-chloride. The final HPLC separations are carried out on a reversed-phase column in a rapid isocratic run. The use of the cis isomer of hydroxyproline as an internal standard allows good reproducibility. As an application of the described method, the hydroxyproline content in samples containing collagen and an excess of bovine serum albumine (up to 20:1) is determined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Respiratory toxicity of multi-wall carbon nanotubes
Muller, J., Huaux, F., Moreau, N., Misson, P., Heilier, J.-F., Delos, M., Arras, M., Fonseca, A., Nagy, J. B., & Lison, D. (2005) · Toxicology and Applied Pharmacology · doi:10.1016/j.taap.2005.01.008 · Cited by 1,123
“Hydroxyproline was assessed by high-performance liquid chromatography analysis in lung homogenates hydrolyzed in 6N HCl overnight at 110 8C (Biondi et al., 1997).”
MethodFenoglio, I., Greco, G., Tomatis, M., Muller, J., Raymundo-Piñero, E., Béguin, F., Fonseca, A., Nagy, J. B., Lison, D., & Fubini, B. (2008) · Chemical Research in Toxicology · doi:10.1021/tx800100s · Cited by 302
Muller, J., Huaux, F., Fonseca, A., Nagy, J. B., Moreau, N., Delos, M., Raymundo-Piñero, E., Béguin, F., Kirsch-Volders, M., Fenoglio, I., et al. (2008) · Chemical Research in Toxicology · doi:10.1021/tx800101p · Cited by 261
Sintered indium-tin-oxide (ITO) particles: a new pneumotoxic entity
Lison, D., Laloy, J., Corazzari, I., Muller, J., Rabolli, V., Panin, N., Huaux, F., Fenoglio, I., & Fubini, B. (2009) · Toxicological Sciences · doi:10.1093/toxsci/kfp014 · Cited by 109
“The fibrotic response was also assessed biochemically in separate groups of animals by measuring the lung hydroxyproline (Biondi et al., 1997) and soluble”
Arras, M., Louahed, J., Simoen, V., Barbarin, V., Misson, P., van den Brûle, S., Delos, M., Knoops, L., Renauld, J.-C., Lison, D., et al. (2006) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/rcmb.2004-0383oc · Cited by 46
Metadata
- Authors
- Biondi, P. A., Chiesa, L. M., Storelli, M. R., & Renon, P.
- Venue
- Journal of Chromatographic Science
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-11-01
- Volume
- 35
- Issue
- 11
- Pages
- 509-512
- ISSN
- 0021-9665 (ISSN-L)
- 1945-239X
- OpenAlex
- W2152587418
- Cited by
- 36
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.