CoChat

New enzymatic method for serum uric acid at 500 nm.

Trivedi, R C, Rebar, L, Berta, E, Stong, L · 1978 · Clinical Chemistry
Cited by 130

The DOI matches its Crossref record.

Abstract

We describe a manual method, well suited to mechanization, for quantitating serum uric acid at 500 nm. In the assay mixture (0.10 ml of sample and 3.00 ml of reagent) the hydrogen peroxide produced from uric acid by uricase is coupled with p-hydroxybenzoate and 4-aminoantipyrine in the presence of peroxidase to form a colored complex, which is measured. A separate sample blank is obviated by taking an initial absorbance measurement 20 s after the sample is added. The reaction is complete within 5 min; its sensitivity is 0.001 deltaA/mg per liter. Absorbances are linearly related to uric acid concentrations up to 120 mg/liter. Many substances that may be present in normal serum do not interfere, but bilirubin in moderately above-normal concentrations will interfere. The procedure can be modified to largely correct for this, when necessary. The proposed method (y) correlated well (r = 0.979) with the uric acid 293 nm reference method (x) and the relation is described by the equation y = 0.998x + 2.42.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/24.11.1908

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 130

Metadata

Authors
Trivedi, R. C., Rebar, L., Berta, E., & Stong, L.
Venue
Clinical Chemistry
Published
1978-11-01
Volume
24
Issue
11
Pages
1908-1911
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1859919035
Cited by
130
References
0
FWCI
1.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: New enzymatic method for serum uric acid at 500 nm. https://app.cochat.ai/papers/10.1093/clinchem/24.11.1908
The paper
Trivedi, R. C., Rebar, L., Berta, E., & Stong, L. (1978). New enzymatic method for serum uric acid at 500 nm. Clinical Chemistry. https://doi.org/10.1093/clinchem/24.11.1908

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.