New enzymatic method for serum uric acid at 500 nm.
The DOI matches its Crossref record.
Abstract
We describe a manual method, well suited to mechanization, for quantitating serum uric acid at 500 nm. In the assay mixture (0.10 ml of sample and 3.00 ml of reagent) the hydrogen peroxide produced from uric acid by uricase is coupled with p-hydroxybenzoate and 4-aminoantipyrine in the presence of peroxidase to form a colored complex, which is measured. A separate sample blank is obviated by taking an initial absorbance measurement 20 s after the sample is added. The reaction is complete within 5 min; its sensitivity is 0.001 deltaA/mg per liter. Absorbances are linearly related to uric acid concentrations up to 120 mg/liter. Many substances that may be present in normal serum do not interfere, but bilirubin in moderately above-normal concentrations will interfere. The procedure can be modified to largely correct for this, when necessary. The proposed method (y) correlated well (r = 0.979) with the uric acid 293 nm reference method (x) and the relation is described by the equation y = 0.998x + 2.42.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Facchini, F. (1991) · JAMA · doi:10.1001/jama.1991.03470210076036 · Cited by 885
Dehghan, A., Köttgen, A., Yang, Q., Hwang, S.-J., Kao, W. L., Rivadeneira, F., Boerwinkle, E., Levy, D., Hofman, A., Astor, B. C., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)61343-4 · Cited by 718
High Serum Uric Acid as a Novel Risk Factor for Type 2 Diabetes
Dehghan, A., van Hoek, M., Sijbrands, E. J. G., Hofman, A., & Witteman, J. C. M. (2008) · Diabetes Care · doi:10.2337/dc07-1276 · Cited by 652
Uric Acid Is a Risk Factor for Myocardial Infarction and Stroke: The Rotterdam Study
Bos, M. J., Koudstaal, P. J., Hofman, A., Witteman, J. C. M., & Breteler, M. M. B. (2006) · Stroke · doi:10.1161/01.str.0000221716.55088.d4 · Cited by 615
Yang, Q., Köttgen, A., Dehghan, A., Smith, A. V., Glazer, N. L., Chen, M.-H., Chasman, D. I., Aspelund, T., Eiriksdottir, G., Harris, T. B., et al. (2010) · Circulation: Cardiovascular Genetics · doi:10.1161/circgenetics.109.934455 · Cited by 320
Farshchi, H. R., Taylor, M. A., & Macdonald, I. A. (2005) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn.81.2.388 · Cited by 302
“Plasma uric acid concentration was measured enzymatically (29, 30) by using kits supplied by VITROS.”
MethodSerum uric acid levels and the risk of Parkinson disease
de Lau, L. M. L., Koudstaal, P. J., Hofman, A., & Breteler, M. M. B. (2005) · Annals of Neurology · doi:10.1002/ana.20663 · Cited by 301
Farshchi, H. R., Taylor, M. A., & Macdonald, I. A. (2005) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/81.1.16 · Cited by 286
Serum uric acid and cognitive function and dementia
Euser, S. M., Hofman, A., Westendorp, R. G. J., & Breteler, M. M. B. (2008) · Brain · doi:10.1093/brain/awn316 · Cited by 253
Farshchi, H. R., Taylor, M. A., & Macdonald, I. A. (2004) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601935 · Cited by 169
Barros, M. P., Ganini, D., Lorenço-Lima, L., Soares, C. O., Pereira, B., Bechara, E. J., Silveira, L. R., Curi, R., & Souza-Junior, T. P. (2012) · Journal of the International Society of Sports Nutrition · doi:10.1186/1550-2783-9-25 · Cited by 15
Metadata
- Authors
- Trivedi, R. C., Rebar, L., Berta, E., & Stong, L.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1978-11-01
- Volume
- 24
- Issue
- 11
- Pages
- 1908-1911
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1859919035
- Cited by
- 130
- References
- 0
- FWCI
- 1.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.