Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 234

The DOI matches its Crossref record.

Free-zone electrophoresis in glass capillaries.

Jorgenson, J W, Lukacs, K D·1981·Clinical Chemistry

Abstract

A simple theory of zone electrophoresis in open-tubular capillaries is developed. According to this theory, to achieve the highest resolution of zones, tubes with as small an inside diameter as possible should be used in combination with as high an applied voltage as feasible. To test this approach, we performed electrophoresis in glass capillaries with an internal diameter of 75 micron and a length of 100 cm. A special fluorescence detector was used to detect fluorescent zones while they migrated inside the capillary. With the application of 30 kV potentials to this system, rapid and efficient separations of amino acids, peptides, and urinary amines were demonstrated. In all cases fluorescent derivatives were necessary for detection. Preliminary results are encouraging, and with further development of sensitive detection devices, applications in clinical analyses may be feasible.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/27.9.1551

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 234

Metadata

Authors
Jorgenson, J. W., & Lukacs, K. D.
Venue
Clinical Chemistry
Published
1981-09-01
Volume
27
Issue
9
Pages
1551-1553
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1904949101
Cited by
234
References
0
FWCI
2.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Free-zone electrophoresis in glass capillaries. https://app.cochat.ai/papers/10.1093/clinchem/27.9.1551
The paper
Jorgenson, J. W., & Lukacs, K. D. (1981). Free-zone electrophoresis in glass capillaries. Clinical Chemistry. https://doi.org/10.1093/clinchem/27.9.1551

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.