CoChat

An improved ultrafiltration method for determining free testosterone in serum.

Vlahos, I, MacMahon, W, Sgoutas, D, Bowers, W, Thompson, J, Trawick, W · 1982 · Clinical Chemistry
Cited by 86

The DOI matches its Crossref record.

Abstract

In this method, we use the Amicon MPS-1 centrifugal ultrafiltration device and the YMB membrane in measuring free testosterone in serum. Two independent assays are combined: total testosterone and the ultrafiltrable fraction of added [3H]testosterone. The unbound fraction is determined in 0.15-0.5 mL ultrafiltrates of 0.6 to 1 mL of variably diluted serum that has been equilibrated with [3H]testosterone at 37 degrees C. The assay is rapid (less than 1 h), practicable (requires 0.6 mL of serum), and reproducible (CV 3.2% within assay, 3.9% between assays). Accuracy was evaluated as the fraction of free testosterone in the ultrafiltrate of dialyzed serum vs that in a prior dialysate; they were the same confirming the validity of the free testosterone measurement. Samples from ostensibly healthy men and women and from hirsute and pregnant women gave results that agreed with those obtained by equilibrium dialysis. Total testosterone concentrations for normal and hirsute women showed considerable overlap, but data on free testosterone concentrations in these populations were better resolved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/28.11.2286

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Vlahos, I., MacMahon, W., Sgoutas, D., Bowers, W., Thompson, J., & Trawick, W.
Venue
Clinical Chemistry
Published
1982-11-01
Volume
28
Issue
11
Pages
2286-2291
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1895304197
Cited by
86
References
0
FWCI
2.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.