The DOI matches its Crossref record.
Time-resolved fluorometer for lanthanide chelates--a new generation of nonisotopic immunoassays.
Abstract
Pulsed-light time-resolved fluorometry of lanthanide chelates has proved to be very sensitive for use with nonisotopic immunoassays. We describe a manually operated fluorometer with a conventional xenon flashtube. Sensitivity for 1-s determinations is similar to that of radioisotopic methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Long-Lived Emissive Probes for Time-Resolved Photoluminescence Bioimaging and Biosensing
Zhang, K. Y., Yu, Q., Wei, H., Liu, S., Zhao, Q., & Huang, W. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00425 · Cited by 923
Europium as a label in time-resolved immunofluorometric assays
Hemmilä, I., Dakubu, S., Mukkala, V.-M., Siitari, H., & Lövgren, T. (1984) · Analytical Biochemistry · doi:10.1016/0003-2697(84)90095-2 · Cited by 833
A Ligase-Mediated Gene Detection Technique
Landegren, U., Kaiser, R., Sanders, J., & Hood, L. (1988) · Science · doi:10.1126/science.3413476 · Cited by 828
Gruenberg, J., Griffiths, G., & Howell, K. E. (1989) · The Journal of cell biology · doi:10.1083/jcb.108.4.1301 · Cited by 587
Immunoassays with time-resolved fluorescence spectroscopy: Principles and applications
Diamandis, E. P. (1988) · Clinical Biochemistry · doi:10.1016/0009-9120(88)90001-x · Cited by 307
Ligand assays: from electrophoresis to miniaturized microarrays
Ekins, R. P. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.9.2015 · Cited by 299
Freir, D. B., Nicoll, A. J., Klyubin, I., Panico, S., Mc Donald, J. M., Risse, E., Asante, E. A., Farrow, M. A., Sessions, R. B., Saibil, H. R., et al. (2011) · Nature Communications · doi:10.1038/ncomms1341 · Cited by 293
DNA Diagnostics—Molecular Techniques and Automation
Landegren, U., Kaiser, R., Caskey, C. T., & Hood, L. (1988) · Science · doi:10.1126/science.3051381 · Cited by 281
Antibodies against metal chelates
Reardan, D. T., Meares, C. F., Goodwin, D. A., McTigue, M., David, G. S., Stone, M. R., Leung, J. P., Bartholomew, R. M., & Frincke, J. M. (1985) · Nature · doi:10.1038/316265a0 · Cited by 260
Amyloid-β nanotubes are associated with prion protein-dependent synaptotoxicity
Nicoll, A. J., Panico, S., Freir, D. B., Wright, D., Terry, C., Risse, E., Herron, C. E., O’Malley, T., Wadsworth, J. D. F., Farrow, M. A., et al. (2013) · Nature Communications · doi:10.1038/ncomms3416 · Cited by 119
Trumpff, C., De Schepper, J., Vanderfaeillie, J., Vercruysse, N., Van Oyen, H., Moreno-Reyes, R., Tafforeau, J., Vanderpas, J., & Vandevijvere, S. (2015) · Nutrients · doi:10.3390/nu7115450 · Cited by 52
“TSH levels were measured by a commercial time-resolved fluoroimmunoassay (Autodelfia method) in dried blood spots on filter paper, which were collected by heel stick between 3 to 5 days after birth [14].”
MethodNeonatal thyroid-stimulating hormone concentration and psychomotor development at preschool age
Trumpff, C., De Schepper, J., Vanderfaeillie, J., Vercruysse, N., Van Oyen, H., Moreno-Reyes, R., Tafforeau, J., & Vandevijvere, S. (2016) · Archives of Disease in Childhood · doi:10.1136/archdischild-2015-310006 · Cited by 42
Metadata
- Authors
- Soini, E., & Kojola, H.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1983-01-01
- Volume
- 29
- Issue
- 1
- Pages
- 65-68
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1888269707
- Cited by
- 386
- References
- 0
- FWCI
- 20.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.