The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
Interferences in Immunoassay
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CHRONIC COUGH: EOSINOPHILIC BRONCHITIS WITHOUT ASTHMA
Gibson, P. G., Denburg, J., Dolovich, J., Ramsdale, E. H., & Hargreave, F. E. (1989) · The Lancet · doi:10.1016/s0140-6736(89)92801-8 · Cited by 665
Human Anti-Animal Antibody Interferences in Immunological Assays
Kricka, L. J. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.7.942 · Cited by 586
Self-citationTate, J. R., & Ward, G. (2004) · PubMed · Cited by 548
Afif, W., Loftus, E. V., Faubion, W. A., Kane, S. V., Bruining, D. H., Hanson, K. A., & Sandborn, W. J. (2010) · American Journal of Gastroenterology · doi:10.1038/ajg.2010.9 · Cited by 486
Selby, C. (1999) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456329903600603 · Cited by 316
Heterophilic antibodies: a problem for all immunoassays.
Boscato, L. M., & Stuart, M. C. (1988) · Clinical Chemistry · doi:10.1093/clinchem/34.1.27 · Cited by 300
Interference with clinical laboratory analyses
Kroll, M. H., & Elin, R. J. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.11.1996 · Cited by 269
Antibody interference in thyroid assays: a potential for clinical misinformation
Després, N., & Grant, A. M. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.3.440 · Cited by 262
Use of porcine factor VIII in the treatment of patients with acquired hemophilia
Morrison, A., Ludlam, C., & Kessler, C. (1993) · Blood · doi:10.1182/blood.v81.6.1513.1513 · Cited by 254
Impact of blood collection devices on clinical chemistry assays
Bowen, R. A. R., Hortin, G. L., Csako, G., Otañez, O. H., & Remaley, A. T. (2010) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.10.001 · Cited by 240
Cited by
Interferences from blood collection tube components on clinical chemistry assays
Bowen, R. A. R., & Remaley, A. T. (2014) · Biochemia Medica · doi:10.11613/bm.2014.006 · Cited by 316
Interferences With Thyroid Function Immunoassays: Clinical Implications and Detection Algorithm
Favresse, J., Burlacu, M.-C., Maiter, D., & Gruson, D. (2018) · Endocrine Reviews · doi:10.1210/er.2018-00119 · Cited by 258
Challenges for measuring oxytocin: the blind men and the elephant?
MacLean, E. L., Wilson, S. R., Martin, W. L., Davis, J. M., Nazarloo, H. P., & Carter, C. S. (2019) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2019.05.018 · Cited by 183
Macro-Thyrotropin: A Case Report and Review of Literature
Loh, T. P., Kao, S. L., Halsall, D. J., Toh, S.-A. E. S., Chan, E., Ho, S. C., Tai, E. S., & Khoo, C. M. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2011-3490 · Cited by 84
The potential clinical value of plasma biomarkers in Alzheimer's disease
Blennow, K., Galasko, D., Perneczky, R., Quevenco, F., van der Flier, W. M., Akinwonmi, A., Carboni, M., Jethwa, A., Suridjan, I., & Zetterberg, H. (2023) · Alzheimer's & Dementia · doi:10.1002/alz.13455 · Cited by 75
Metadata
- Authors
- Park, J. Y., & Kricka, L. J.
- Venue
- The Immunoassay Handbook
- Publisher
- Elsevier
- Published
- 2013
- Pages
- 403-416
- OpenAlex
- W203448064
- Cited by
- 365
- References
- 69
- FWCI
- 91.35
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interferences in Immunoassay. https://app.cochat.ai/papers/10.1016/b978-0-08-097037-0.00027-0
- The paper
- Park, J. Y., & Kricka, L. J. (2013). Interferences in Immunoassay. The Immunoassay Handbook. https://doi.org/10.1016/b978-0-08-097037-0.00027-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.