Stabilization of ascorbic acid in human plasma, and its liquid-chromatographic measurement.
The DOI matches its Crossref record.
Abstract
We describe two independent HPLC procedures for the rapid, accurate analysis for ascorbic acid in human plasma. No sample extraction or phase separation is required. We also describe a procedure for preparing a human plasma reference material for use in clinical laboratory analysis for ascorbic acid. The ascorbic acid in plasma can be determined in 15 min, with as little as 50 microL of sample. Analytical recoveries are near 100% with direct injection of deproteinized plasma. Extensive stability data under several conditions, with dithiothreitol as a preservative (antioxidant), indicate that ascorbic acid remains stable in stored plasma for as long as 57 weeks. CVs for round-robin analysis of 11 normal human blood samples by two independent methods were between 0.1% and 5.3%. These clinical samples appear to be stable for at least 50 days under the described conditions of stabilization and sample treatment. Finally, because ascorbic acid prepared by the described procedures is stable at room temperature for at least 18 h, these methods can be readily adapted to clinical laboratory automation at room temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bingham, S. (1997) · International Journal of Epidemiology · doi:10.1093/ije/26.suppl_1.s137 · Cited by 634
Vitamin Analysis for the Health and Food Sciences
Eitenmiller, R., & Landen, W. (1998) · CRC Press eBooks · doi:10.1201/9781420050165 · Cited by 546
John, J., Ziebland, S., Yudkin, P., Roe, L., & Neil, H. (2002) · The Lancet · doi:10.1016/s0140-6736(02)98858-6 · Cited by 527
Bingham, S. A., Cassidy, A., Cole, T. J., Welch, A., Runswick, S. A., Black, A. E., Thurnham, D., Bates, C., Khaw, K. T., Key, T. J. A., et al. (1995) · British Journal of Nutrition · doi:10.1079/bjn19950057 · Cited by 377
“Plasma vitamin C was measured by liquid chromatography with electrochemical detection in both groups (Bates & Cowen, 1988; Margolis & Davis, 1988).”
Borrelli, E., Roux-Lombard, P., Grau, G. E., Girardin, E., Ricou, B., Dayer, J.-M., & Suter, P. M. (1996) · Critical Care Medicine · doi:10.1097/00003246-199603000-00006 · Cited by 349
Metadata
- Authors
- Margolis, S. A., & Davis, T. P.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1988-11-01
- Volume
- 34
- Issue
- 11
- Pages
- 2217-2223
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1887476347
- Cited by
- 91
- References
- 0
- FWCI
- 1.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stabilization of ascorbic acid in human plasma, and its liquid-chromatographic measurement. https://app.cochat.ai/papers/10.1093/clinchem/34.11.2217
- The paper
- Margolis, S. A., & Davis, T. P. (1988). Stabilization of ascorbic acid in human plasma, and its liquid-chromatographic measurement. Clinical Chemistry. https://doi.org/10.1093/clinchem/34.11.2217
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.