Development of Monoclonal Antibodies for an Assay of Cardiac Troponin-I and Preliminary Results in Suspected Cases of Myocardial Infarction
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
To improve the specificity of biochemical markers of myocardial infarction (MI), we have developed a double monoclonal "sandwich" enzyme immunoassay to measure cardiac troponin-I (cTnI) in serum. We produced eight IgG monoclonal antibodies against human cardiac troponin-I (cTnI) and tested them against human and animal (canine, bovine, and rabbit) troponins. Five antibodies were cardiac-specific; none of the antibodies were species-specific. Two of the five cTnI-specific monoclonal antibodies were utilized in an immunoassay. Standards were made by adding purified human cTnI to affinity-stripped cTnI-free human sera to cover the range 0-100 micrograms/L for cTnI. The dose-response curve was nonlinear but reproducible. Total assay imprecision (CV) varied between 11% and 21%. The upper limit of the reference range (nonparametric 95% interval) was established as 3.1 micrograms/L by measuring cTnI concentration in sera of 159 hospitalized patients without evidence of cardiac disease. Purified human skeletal TnI up to 10,000 micrograms/L did not affect the assay (calculated cross-reactivity < 0.1%). Diagnostic sensitivities of creatine kinase MB isoenzyme (CK-MB) and cTnI were evaluated retrospectively in 49 consecutive patients with proven MI. In the 30 patients for whom sufficient information was available to establish an accurate time course, CK-MB was more sensitive during the first 4 h after the onset of chest pain, but thereafter the sensitivities were similar up to 48 h. However, cTnI is more cardiac-specific than is CK-MB and remains increased longer than does CK-MB.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cleavage of Structural Proteins during the Assembly of the Head of Bacteriophage T4
LAEMMLI, U. K. (1970) · Nature · doi:10.1038/227680a0 · Cited by 249,961
A multi-rule Shewhart chart for quality control in clinical chemistry.
Westgard, J. O., Barry, P. L., Hunt, M. R., & Groth, T. (1981) · Clinical Chemistry · doi:10.1093/clinchem/27.3.493 · Cited by 831
Diagnostic efficiency of troponin T measurements in acute myocardial infarction.
Katus, H. A., Remppis, A., Neumann, F. J., Scheffold, T., Diederich, K. W., Vinar, G., Noe, A., Matern, G., & Kuebler, W. (1991) · Circulation · doi:10.1161/01.cir.83.3.902 · Cited by 814
Cardiac-specific troponin-l radioimmunoassay in the diagnosis of acute myocardial infarction
Cummins, B., Auckland, M. L., & Cummins, P. (1987) · American Heart Journal · doi:10.1016/0002-8703(87)90645-4 · Cited by 429
LEE, T. H., & GOLDMAN, L. (1986) · Annals of Internal Medicine · doi:10.7326/0003-4819-105-2-221 · Cited by 264
Lott, J. A., & Stang, J. M. (1980) · Clinical Chemistry · doi:10.1093/clinchem/26.9.1241 · Cited by 208
Troponin I Switching in the Developing Heart
Saggin, L., Gorza, L., Ausoni, S., & Schiaffino, S. (1989) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)71621-9 · Cited by 206
Molecular cloning of human cardiac troponin I using polymerase chain reaction
Vallins, W. J., Brand, N. J., Dabhade, N., Butler-Browne, G., Yacoub, M. H., & Barton, P. J. R. (1990) · FEBS Letters · doi:10.1016/0014-5793(90)81234-f · Cited by 145
Syska, H., Perry, S. V., & Trayer, I. P. (1974) · FEBS Letters · doi:10.1016/0014-5793(74)80238-3 · Cited by 133
Cummins, P. L., Young, A., Auckland, M. L., Michie, C. A., Stone, P. C. W., & SHEPSTONE, B. J. (1987) · European Journal of Clinical Investigation · doi:10.1111/j.1365-2362.1987.tb02194.x · Cited by 128
Cited by
Antman, E. M., Tanasijevic, M. J., Thompson, B., Schactman, M., McCabe, C. H., Cannon, C. P., Fischer, G. A., Fung, A. Y., Thompson, C., Wybenga, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199610313351802 · Cited by 1,749
Cardiac troponin I. A marker with high specificity for cardiac injury.
Adams, J. E., Bodor, G. S., Dávila-Román, V. G., Delmez, J. A., Apple, F. S., Ladenson, J. H., & Jaffe, A. S. (1993) · Circulation · doi:10.1161/01.cir.88.1.101 · Cited by 1,148
Self-citationTroponin: the biomarker of choice for the detection of cardiac injury
Babuin, L., & Jaffe, A. S. (2005) · Canadian Medical Association Journal · doi:10.1503/cmaj.050141 · Cited by 686
NACB WRITING GROUP MEMBERS, Morrow, D. A., Cannon, C. P., Jesse, R. L., Newby, L. K., Ravkilde, J., Storrow, A. B., Wu, A. H. B., & Christenson, R. H. (2007) · Circulation · doi:10.1161/circulationaha.107.182882 · Cited by 610
Biochemical markers of myocardial injury. Is MB creatine kinase the choice for the 1990s?
Adams, J. E., Abendschein, D. R., & Jaffe, A. S. (1993) · Circulation · doi:10.1161/01.cir.88.2.750 · Cited by 554
Left ventricular dysfunction predicted by early troponin I release after high-dose chemotherapy
Cardinale, D., Sandri, M. T., Martinoni, A., Tricca LabTech, A., Civelli, M., Lamantia, G., Cinieri, S., Martinelli, G., Cipolla, C. M., & Fiorentini, C. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00748-8 · Cited by 551
Diagnosis of Perioperative Myocardial Infarction with Measurement of Cardiac Troponin I
Adams, J. E., Sicard, G. A., Allen, B. T., Bridwell, K. H., Lenke, L. G., Davila-Roman, V. G., Bodor, G. S., Ladenson, J. H., & Jaffe, A. S. (1994) · New England Journal of Medicine · doi:10.1056/nejm199403103301003 · Cited by 527
Self-citationLandesberg, G., Shatz, V., Akopnik, I., Wolf, Y. G., Mayer, M., Berlatzky, Y., Weissman, C., & Mosseri, M. (2003) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.05.001 · Cited by 486
NACB WRITING GROUP MEMBERS, Morrow, D. A., Cannon, C. P., Jesse, R. L., Newby, L. K., Ravkilde, J., Storrow, A. B., Wu, A. H. B., Christenson, R. H., NACB COMMITTEE MEMBERS, et al. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.084194 · Cited by 474
Elevations of Cardiac Troponin I Associated With Myocarditis: Experimental and Clinical Correlates
Smith, S. C., Ladenson, J. H., Mason, J. W., & Jaffe, A. S. (1997) · Circulation · doi:10.1161/01.cir.95.1.163 · Cited by 446
Self-citationWu, A. H. B., Feng, Y.-J., Moore, R., Apple, F. S., McPherson, P. H., Buechler, K. F., Bodor, G., for, F. T. A. A., & Standardization, C. C. S. O. C. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.6.1198 · Cited by 393
Self-citationRole of Troponin I Proteolysis in the Pathogenesis of Stunned Myocardium
Gao, W. D., Atar, D., Liu, Y., Perez, N. G., Murphy, A. M., & Marban, E. (1997) · Circulation Research · doi:10.1161/01.res.0000435855.49359.47 · Cited by 392
Myocardial injury revealed by plasma troponin I in breast cancer treated with high-dose chemotherapy
Cardinale, D., Sandri, M. T., Martinoni, A., Borghini, E., Civelli, M., Lamantia, G., Cinieri, S., Martinelli, G., Fiorentini, C., & Cipolla, C. M. (2002) · Annals of Oncology · doi:10.1093/annonc/mdf170 · Cited by 313
Cardiac Troponin I Predicts Short-Term Mortality in Vascular Surgery Patients
Kim, L. J., Martinez, E. A., Faraday, N., Dorman, T., Fleisher, L. A., Perler, B. A., Williams, G. M., Chan, D., & Pronovost, P. J. (2002) · Circulation · doi:10.1161/01.cir.0000036016.52396.bb · Cited by 308
Diagnostics on acute myocardial infarction: Cardiac troponin biomarkers
Fathil, M. F. M., Md Arshad, M. K., Gopinath, S. C. B., Hashim, U., Adzhri, R., Ayub, R. M., Ruslinda, A. R., Nuzaihan M.N., M., Azman, A. H., Zaki, M., et al. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.03.037 · Cited by 277
Measurement of Cardiac Troponins
Collinson, P. O., Boa, F. G., & Gaze, D. C. (2001) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456320103800501 · Cited by 275
Jo, H., Gu, H., Jeon, W., Youn, H., Her, J., Kim, S.-K., Lee, J., Shin, J. H., & Ban, C. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02312 · Cited by 270
Katrukha, A. G., Bereznikova, A. V., Esakova, T. V., Pettersson, K., Lövgren, T., Severina, M. E., Pulkki, K., Vuopio-Pulkki, L.-M., & Gusev, N. B. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.8.1379 · Cited by 266
“This approach was also used for obtaining antibodies against human cTnI [9, 10, 12].”
MethodKuhn, E., Addona, T., Keshishian, H., Burgess, M., Mani, D. R., Lee, R. T., Sabatine, M. S., Gerszten, R. E., & Carr, S. A. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2009.123935 · Cited by 247
Improved detection of cardiac confusion with cardiac troponin I
Adams, J. E., Dávila-Román, V. G., Bessey, P. Q., Blake, D. P., Ladenson, J. H., & Jaffe, A. S. (1996) · American Heart Journal · doi:10.1016/s0002-8703(96)90359-2 · Cited by 245
Self-citationHigh-sensitivity assays for troponin in patients with cardiac disease
Westermann, D., Neumann, J. T., Sörensen, N. A., & Blankenberg, S. (2017) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2017.48 · Cited by 222
McLaurin, M. D., Apple, F. S., Voss, E. M., Herzog, C. A., & Sharkey, S. W. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.6.976 · Cited by 217
Biochemical markers of myocardial damage
Bhayana, V., & Henderson, A. R. (1995) · Clinical Biochemistry · doi:10.1016/0009-9120(94)00065-4 · Cited by 201
Polanczyk, C. A., Lee, T. H., Cook, E. F., Walls, R., Wybenga, D., Printy-Klein, G., Ludwig, L., Guldbrandsen, G., & Johnson, P. A. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00176-4 · Cited by 175
O’Brien, P. J., Landt, Y., & Ladenson, J. H. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.12.2333 · Cited by 173
“The concentration of cTnI was determined with a research-application, sandwich enzyme immunoassay (Stratus I, Dade International) in which two cTnI-specific murine monoclonal antibodies [ 20 ] are used, 2F6.6 as the capture antibody and 2B1.9 as the labeling antibody.”
BackgroundMethodInfluentialSelf-citation
Metadata
- Authors
- Bodor, G. S., Porter, S., Landt, Y., & Ladenson, J. H.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-11-01
- Volume
- 38
- Issue
- 11
- Pages
- 2203-2214
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2163593130
- Cited by
- 425
- References
- 18
- FWCI
- 9.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.