CoChat

Highly sensitive and specific HPLC with fluorometric detection for determination of plasma epinephrine and norepinephrine applied to kinetic studies in humans

Willemsen, J J, Ross, H A, Jacobs, M C, Lenders, J W, Thien, T, Swinkels, L M, Benraad, T J · 1995 · Clinical Chemistry
Cited by 92

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

An HPLC separation method combined with fluorometric detection was extended to enable simultaneous assessment of plasma 3H-labeled and endogenous epinephrine (E) and norepinephrine (NE). Forearm fractional extraction (FFE) of 3H-labeled E and NE and of endogenous E was measured in 40 healthy volunteers who were receiving a continuous infusion of 3H-labeled E and NE. Concentrations of arterial and venous E were 26.8 +/- 1.95 (mean +/- SE) and 6.8 +/- 0.75 ng/L, respectively. Arterial and venous NE and dopamine (DA) were also measured, with respective values of 140.7 +/- 8.5 and 192.1 +/- 15.1 for NE, and 13.1 +/- 0.78 and 11.3 +/- 0.70 ng/L for DA. The FFE of 3H-labeled E was slightly but significantly higher (0.790 +/- 0.016) than the that of either 3H-labeled NE or endogenous E (0.748 +/- 0.0146 and 0.745 +/- 0.0185, respectively; P < 0.001), the correlations being highly significant (r = 0.80, P < 0.001) in both cases. The small difference between the FFE of E and of 3H-labeled E allows the calculation of the apparent spillover of E. However, this spillover was negligible compared with forearm NE spillover (0.0112 +/- 0.0031 vs 1.369 +/- 0.128 ng/L per minute. The high sensitivity of this measurement of venous E widens the possibilities for studying E kinetics under physiological conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/41.10.1455

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 92

Metadata

Authors
Willemsen, J. J., Ross, H. A., Jacobs, M. C., Lenders, J. W., Thien, T., Swinkels, L. M., & Benraad, T. J.
Venue
Clinical Chemistry
Published
1995-10-01
Volume
41
Issue
10
Pages
1455-1460
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2159204249
Cited by
92
References
1
FWCI
1.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly sensitive and specific HPLC with fluorometric detection for determination of plasma epinephrine and norepinephrine applied to kinetic studies in humans. https://app.cochat.ai/papers/10.1093/clinchem/41.10.1455
The paper
Willemsen, J. J., Ross, H. A., Jacobs, M. C., Lenders, J. W., Thien, T., Swinkels, L. M., & Benraad, T. J. (1995). Highly sensitive and specific HPLC with fluorometric detection for determination of plasma epinephrine and norepinephrine applied to kinetic studies in humans. Clinical Chemistry. https://doi.org/10.1093/clinchem/41.10.1455

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.