Highly sensitive and specific HPLC with fluorometric detection for determination of plasma epinephrine and norepinephrine applied to kinetic studies in humans
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
An HPLC separation method combined with fluorometric detection was extended to enable simultaneous assessment of plasma 3H-labeled and endogenous epinephrine (E) and norepinephrine (NE). Forearm fractional extraction (FFE) of 3H-labeled E and NE and of endogenous E was measured in 40 healthy volunteers who were receiving a continuous infusion of 3H-labeled E and NE. Concentrations of arterial and venous E were 26.8 +/- 1.95 (mean +/- SE) and 6.8 +/- 0.75 ng/L, respectively. Arterial and venous NE and dopamine (DA) were also measured, with respective values of 140.7 +/- 8.5 and 192.1 +/- 15.1 for NE, and 13.1 +/- 0.78 and 11.3 +/- 0.70 ng/L for DA. The FFE of 3H-labeled E was slightly but significantly higher (0.790 +/- 0.016) than the that of either 3H-labeled NE or endogenous E (0.748 +/- 0.0146 and 0.745 +/- 0.0185, respectively; P < 0.001), the correlations being highly significant (r = 0.80, P < 0.001) in both cases. The small difference between the FFE of E and of 3H-labeled E allows the calculation of the apparent spillover of E. However, this spillover was negligible compared with forearm NE spillover (0.0112 +/- 0.0031 vs 1.369 +/- 0.128 ng/L per minute. The high sensitivity of this measurement of venous E widens the possibilities for studying E kinetics under physiological conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overflow of catecholamine neurotransmitters to the circulation: source, fate, and functions
Esler, M., Jennings, G., Lambert, G., Meredith, I., Horne, M., & Eisenhofer, G. (1990) · Physiological Reviews · doi:10.1152/physrev.1990.70.4.963 · Cited by 794 · cited 1×
“Such neuronal release of E, however, has been demonstrated only in the heart at very high rates of nerve stimulation, but not in unstimulated skeletal muscle (14).”
Background
Cited by
Caffeine Can Decrease Insulin Sensitivity in Humans
Keijzers, G. B., De Galan, B. E., Tack, C. J., & Smits, P. (2002) · Diabetes Care · doi:10.2337/diacare.25.2.364 · Cited by 358
“Plasma catecholamine levels were measured by HPLC with fluorometric detection, as previously described (17).”
Kox, M., van Eijk, L. T., Zwaag, J., van den Wildenberg, J., Sweep, F. C. G. J., van der Hoeven, J. G., & Pickkers, P. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1322174111 · Cited by 268
“Plasma norepinephrine, epinephrine, and dopamine concentrations were measured using routine analysis methods also used for patient samples (HPLCy with fluorometric detection, as described previously) (30).”
MethodTack, C. J. J., Ong, M. K. E., Lutterman, J. A., & Smits, P. (1998) · Diabetologia · doi:10.1007/s001250050948 · Cited by 177
“chromatography (HPLC) with fluorometric detection [19].”
Brinkmann, J., Heusser, K., Schmidt, B. M., Menne, J., Klein, G., Bauersachs, J., Haller, H., Sweep, F. C., Diedrich, A., Jordan, J., et al. (2012) · Hypertension · doi:10.1161/hypertensionaha.112.201186 · Cited by 166
Masuo, K., Katsuya, T., Fu, Y., Rakugi, H., Ogihara, T., & Tuck, M. L. (2005) · Circulation · doi:10.1161/circulationaha.104.519652 · Cited by 123
Metadata
- Authors
- Willemsen, J. J., Ross, H. A., Jacobs, M. C., Lenders, J. W., Thien, T., Swinkels, L. M., & Benraad, T. J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1995-10-01
- Volume
- 41
- Issue
- 10
- Pages
- 1455-1460
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2159204249
- Cited by
- 92
- References
- 1
- FWCI
- 1.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly sensitive and specific HPLC with fluorometric detection for determination of plasma epinephrine and norepinephrine applied to kinetic studies in humans. https://app.cochat.ai/papers/10.1093/clinchem/41.10.1455
- The paper
- Willemsen, J. J., Ross, H. A., Jacobs, M. C., Lenders, J. W., Thien, T., Swinkels, L. M., & Benraad, T. J. (1995). Highly sensitive and specific HPLC with fluorometric detection for determination of plasma epinephrine and norepinephrine applied to kinetic studies in humans. Clinical Chemistry. https://doi.org/10.1093/clinchem/41.10.1455
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.