Rapid diagnosis of homocystinuria and other hypermethioninemias from newborns' blood spots by tandem mass spectrometry
The DOI matches its Crossref record.
Abstract
We report a new method for the diagnosis of homocystinuria and other hypermethioninemias from dried blood spots on newborn screening cards, based on isotope-dilution tandem mass spectrometry. The mean concentration of methionine in 909 unaffected newborns was 19 micromol/L (CV 44%). The variability of results was reduced when the concentration of methionine was expressed relative to that of another amino acid in the same specimen. The mean ratio of methionine to leucine plus isoleucine for these same newborn blood spots was 0.16 (CV 25%). In newborn samples from a collection categorized by a Guthrie bacterial inhibition assay as true positive, unaffected, or falsely positive for hypermethioninemias, the ratio of methionine to leucine for each true-positive specimen was at least 2.5 times greater than for respective age-matched unaffected blood specimens. The ratio for falsely positive samples did not differ from that for unaffected blood samples. We predict that the ratio of methionine to leucine plus isoleucine determined by tandem mass spectrometry will successfully detect hypermethioninemias with very low rates for false positives and false negatives.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Use of Tandem Mass Spectrometry for Multianalyte Screening of Dried Blood Specimens from Newborns
Chace, D. H., Kalas, T. A., & Naylor, E. W. (2003) · Clinical Chemistry · doi:10.1373/clinchem.2003.022178 · Cited by 621
Self-citationMass spectrometry in metabolome analysis
Villas‐Bôas, S. G., Mas, S., Åkesson, M., Smedsgaard, J., & Nielsen, J. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20032 · Cited by 616
Ion activation methods for tandem mass spectrometry
Sleno, L., & Volmer, D. A. (2004) · Journal of Mass Spectrometry · doi:10.1002/jms.703 · Cited by 529
Schulze, A., Lindner, M., Kohlmüller, D., Olgemöller, K., Mayatepek, E., & Hoffmann, G. F. (2003) · Pediatrics · doi:10.1542/peds.111.6.1399 · Cited by 519
Zytkovicz, T. H., Fitzgerald, E. F., Marsden, D., Larson, C. A., Shih, V. E., Johnson, D. M., Strauss, A. W., Comeau, A. M., Eaton, R. B., & Grady, G. F. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.11.1945 · Cited by 505
Guidelines for the diagnosis and management of cystathionine beta‐synthase deficiency
Morris, A. A. M., Kožich, V., Santra, S., Andria, G., Ben‐Omran, T. I. M., Chakrapani, A. B., Crushell, E., Henderson, M. J., Hochuli, M., Huemer, M., et al. (2017) · Journal of Inherited Metabolic Disease · doi:10.1007/s10545-016-9979-0 · Cited by 340
Chace, D. H., Hillman, S. L., Van Hove, J. L. K., & Naylor, E. W. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.11.2106 · Cited by 280
Self-citationRashed, M. S., Bucknall, M. P., Little, D., Awad, A., Jacob, M., Alamoudi, M., Alwattar, M., & Ozand, P. T. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.7.1129 · Cited by 275
Neonatal screening for inborn errors of metabolism: cost, yield and outcome.
Pollitt, Green, McCabe, Booth, Cooper, Leonard, Nicholl, Nicholson, Tunaley, & Virdi (1997) · Health Technology Assessment · doi:10.3310/hta1070 · Cited by 267
Piraud, M., Vianey‐Saban, C., Petritis, K., Elfakir, C., Steghens, J., Morla, A., & Bouchu, D. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1054 · Cited by 266
The use of mass spectrometry to analyze dried blood spots
Wagner, M., Tonoli, D., Varesio, E., & Hopfgartner, G. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21441 · Cited by 262
Chace, D. H., DiPerna, J. C., Mitchell, B. L., Sgroi, B., Hofman, L. F., & Naylor, E. W. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.7.1166 · Cited by 246
“The following method of specimen preparation contained substantial modifications from original articles published previously (23, 32 ). A single 0.48-cm (3/16-inch) disk was punched from dried blood and dried bile specimens into polystyrene flat-bottomed 96-well microtiter plates (Evergreen Scientific).”
MethodInfluentialSelf-citationLacey, J. M., Minutti, C. Z., Magera, M. J., Tauscher, A. L., Casetta, B., McCann, M., Lymp, J., Hahn, S. H., Rinaldo, P., & Matern, D. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.027193 · Cited by 216
Mass Spectrometry in the Clinical Laboratory
Chace, D. H. (2001) · Chemical Reviews · doi:10.1021/cr990077+ · Cited by 214
Self-citationChace, D. H., Kalas, T. A., & Naylor, E. W. (2002) · Annual Review of Genomics and Human Genetics · doi:10.1146/annurev.genom.3.022502.103213 · Cited by 210
Self-citationPandor, A., Eastham, J., Beverley, C., Chilcott, J., & Paisley, S. (2004) · Health Technology Assessment · doi:10.3310/hta8120 · Cited by 201
Metadata
- Authors
- Chace, D. H., Hillman, S. L., Millington, D. S., Kahler, S. G., Adam, B. W., & Levy, H. L.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-03-01
- Volume
- 42
- Issue
- 3
- Pages
- 349-355
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1842459836
- Cited by
- 136
- References
- 0
- FWCI
- 7.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.