Real-time fluorescence genotyping of factor V Leiden during rapid-cycle PCR
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
A single-step method for factor V Leiden genotyping is presented that uses rapid-cycle PCR and simultaneous fluorescence analysis with resonance energy transfer probes. A fragment of the factor V gene containing the mutation is amplified asymmetrically through use of a primer labeled with Cy5TM in the presence of a 3′-fluorescein-labeled probe that covers the mutation site. When the fluorescein probe is annealed to the extension product of the Cy5-labeled primer, the fluorophores are brought into close enough contact for resonance energy transfer to occur. As the temperature increases, the probe melts from its target, decreasing the resonance energy transfer. When the probe is complementary to the product strand, it melts at 65 °C; if the single-base mutation is present, the probe melts at 57 °C. Concurrent amplification and analysis from genomic DNA takes 20–45 min and requires no sample manipulation after the fluorescence thermal cycler is loaded.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Beacons: Probes that Fluoresce upon Hybridization
Tyagi, S., & Kramer, F. R. (1996) · Nature Biotechnology · doi:10.1038/nbt0396-303 · Cited by 4,155
Mutation in blood coagulation factor V associated with resistance to activated protein C
Bertina, R. M., Koeleman, B. P. C., Koster, T., Rosendaal, F. R., Dirven, R. J., de Ronde, H., van der Velden, P. A., & Reitsma, P. H. (1994) · Nature · doi:10.1038/369064a0 · Cited by 3,783
Product Differentiation by Analysis of DNA Melting Curves during the Polymerase Chain Reaction
Ririe, K. M., Rasmussen, R. P., & Wittwer, C. T. (1997) · Analytical Biochemistry · doi:10.1006/abio.1996.9916 · Cited by 1,654
Self-citationLivak, K. J., Flood, S. J., Marmaro, J., Giusti, W., & Deetz, K. (1995) · Genome Research · doi:10.1101/gr.4.6.357 · Cited by 1,603
Continuous Fluorescence Monitoring of Rapid Cycle DNA Amplification
Wittwer, C. T., Herrmann, M. G., Moss, A. A., & Rasmussen, R. P. (2013) · BioTechniques · doi:10.2144/000114043 · Cited by 1,274
Self-citationThe Polymerase Chain Reaction: A New Method of Using Molecular Genetics for Medical Diagnosis
Desforges, J. F., & Eisenstein, B. I. (1990) · New England Journal of Medicine · doi:10.1056/nejm199001183220307 · Cited by 1,158
Continuous Fluorescence Monitoring of Rapid Cycle DNA Amplification
Wittwer, C. T., Herrmann, M. G., Moss, A. A., & Rasmussen, R. P. (1997) · BioTechniques · doi:10.2144/97221bi01 · Cited by 1,143
Self-citationThe LightCycler TM : A Microvolume Multisample Fluorimeter with Rapid Temperature Control
Wittwer, C. T., Ririe, K. M., Andrew, R. V., David, D. A., Gundry, R. A., & Balis, U. J. (1997) · BioTechniques · doi:10.2144/97221pf02 · Cited by 893
Self-citationWallace, R. B., Shaffer, J., Murphy, R. F., Bonner, J., Hirose, T., & Itakura, K. (1979) · Nucleic Acids Research · doi:10.1093/nar/6.11.3543 · Cited by 748
Association of idiopathic venous thromboembolism with single point-mutation at Arg506 of factor V
Voorberg, J., Roelse, J., Mertens, K., van Mourik, J. A., Koopman, R., Büller, H., Berends, F., & ten Cate, J. W. (1994) · The Lancet · doi:10.1016/s0140-6736(94)92939-4 · Cited by 426
Enhanced discrimination of single nucleotide polymorphisms by artificial mismatch hybridization
Guo, Z., Liu, Q., & Smith, L. M. (1997) · Nature Biotechnology · doi:10.1038/nbt0497-331 · Cited by 138
Wittwer, C. T., Reed, G. B., & Ririe, K. M. (1994) · Birkhäuser Boston eBooks · doi:10.1007/978-1-4612-0257-8_15 · Cited by 67
Self-citationDNA extraction with organic solvents in gel barrier tubes
Thomas, S. M., Moreno, R. F., & Tilzer, L. L. (1989) · Nucleic Acids Research · doi:10.1093/nar/17.13.5411 · Cited by 63
Simple and Rapid Detection of Factor V Leiden by Allele-specific PCR Amplification
Blasczyk, R., Ritter, M., Thiede, C., Wehling, J., Hintz, G., Neubauer, A., & Riess, H. (1996) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1650362 · Cited by 19
Cited by
Bustin, S. (2000) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0250169 · Cited by 3,872
Real-Time PCR for mRNA Quantitation
Wong, M. L., & Medrano, J. F. (2005) · BioTechniques · doi:10.2144/05391rv01 · Cited by 1,786
Mackay, I. M. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.6.1292 · Cited by 1,318
High-Resolution Genotyping by Amplicon Melting Analysis Using LCGreen
Wittwer, C. T., Reed, G. H., Gundry, C. N., Vandersteen, J. G., & Pryor, R. J. (2003) · Clinical Chemistry · doi:10.1373/49.6.853 · Cited by 1,257
Self-citationReal-time PCR in the microbiology laboratory
Mackay, I. M. (2004) · Clinical Microbiology and Infection · doi:10.1111/j.1198-743x.2004.00722.x · Cited by 807
Metadata
- Authors
- Lay, M. J., & Wittwer, C. T.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-12-01
- Volume
- 43
- Issue
- 12
- Pages
- 2262-2267
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2113001043
- Cited by
- 331
- References
- 14
- FWCI
- 7.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.