The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Improved troponin T ELISA specific for cardiac troponin T isoform: assay development and analytical and clinical validation
Abstract
The first generation of troponin T ELISA (TnT 1) can yield false-positive results in patients with severe skeletal muscle injury. Therefore, a cardiac-specific second-generation troponin T ELISA (TnT 2) was developed, in which the cross-reactive antibody 1B10 has been replaced by a high-affinity cardiac-specific antibody M11.7. No cross-reactivity of TnT 2 was observed with purified skeletal muscle troponin T (1000 μg/L) or in test samples from 43 marathon runners and 24 patients with rhabdomyolysis and highly increased creatine kinase. TnT 2 was increased >0.2 μg/L in 5 of 40 patients with renal failure and in 4 of 20 muscular dystrophy patients. The detection limit is 0.012 μg/L. Day-to-day imprecision (CV) within the range 0.19–14.89 μg/L was <5.8%. In 4955 patients without myocardial damage, 99.6% had TnT <0.10 μg/L. Assay comparison (TnT 1 vs TnT 2) over the whole concentration range (i.e., in 323 samples from AMI-suspected patients) showed a slope, intercept, and standard error of estimate (Sey) of 1.18, 0.01 μg/L, and 0.81 μg/L, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cleavage of Structural Proteins during the Assembly of the Head of Bacteriophage T4
LAEMMLI, U. K. (1970) · Nature · doi:10.1038/227680a0 · Cited by 249,961
Towbin, H., Staehelin, T., & Gordon, J. (1979) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.76.9.4350 · Cited by 53,385
Geysen, H. M., Meloen, R. H., & Barteling, S. J. (1984) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.81.13.3998 · Cited by 1,475
Unstable angina. A classification.
Braunwald, E. (1989) · Circulation · doi:10.1161/01.cir.80.2.410 · Cited by 1,366
The Prognostic Value of Serum Troponin T in Unstable Angina
Hamm, C. W., Ravkilde, J., Gerhardt, W., Jørgensen, P., Peheim, E., Ljungdahl, L., Goldmann, B., & Katus, H. A. (1992) · New England Journal of Medicine · doi:10.1056/nejm199207163270302 · Cited by 953
Self-citationDiagnostic efficiency of troponin T measurements in acute myocardial infarction.
Katus, H. A., Remppis, A., Neumann, F. J., Scheffold, T., Diederich, K. W., Vinar, G., Noe, A., Matern, G., & Kuebler, W. (1991) · Circulation · doi:10.1161/01.cir.83.3.902 · Cited by 814
Self-citationHamm, C. W., & Bleifeld, W. (1990) · Cited by 497
Eisenberg, E., & Kielley, W. W. (1974) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)42382-x · Cited by 485
Development and In Vitro Characterization of a New Immunoassay of Cardiac Troponin T
Katus, H. A., Looser, S., Hallermayer, K., Remppis, A., Scheffold, T., Borgya, A., Essig, U., & Geuss, U. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.3.386 · Cited by 430
Self-citationGerhardt, W., Katus, H., Ravkilde, J., Hamm, C., Jørgensen, P. J., Peheim, E., Ljungdahl, L., & Löfdahl, P. (1991) · Clinical Chemistry · doi:10.1093/clinchem/37.8.1405 · Cited by 279
Self-citation
Cited by
Lindahl, B., Toss, H., Siegbahn, A., Venge, P., & Wallentin, L. (2000) · New England Journal of Medicine · doi:10.1056/nejm200010193431602 · Cited by 1,224
Hamm, C. W., Heeschen, C., Goldmann, B., Vahanian, A., Adgey, J., Miguel, C. M., Rutsch, W., Berger, J., Kootstra, J., & Simoons, M. L. (1999) · New England Journal of Medicine · doi:10.1056/nejm199905273402103 · Cited by 710
Troponin: the biomarker of choice for the detection of cardiac injury
Babuin, L., & Jaffe, A. S. (2005) · Canadian Medical Association Journal · doi:10.1503/cmaj.050141 · Cited by 686
Wu, A. H., Apple, F. S., Gibler, W. B., Jesse, R. L., Warshaw, M. M., & Valdes, R. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.7.1104 · Cited by 662
Biomarkers in Acute Cardiac Disease
Jaffe, A. S., Babuin, L., & Apple, F. S. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.02.056 · Cited by 639
Metadata
- Authors
- Müller-Bardorff, M., Hallermayer, K., Schröder, A., Ebert, C., Borgya, A., Gerhardt, W., Remppis, A., Zehelein, J., & Katus, H. A.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-03-01
- Volume
- 43
- Issue
- 3
- Pages
- 458-466
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2139727848
- Cited by
- 314
- References
- 16
- FWCI
- 22.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved troponin T ELISA specific for cardiac troponin T isoform: assay development and analytical and clinical validation. https://app.cochat.ai/papers/10.1093/clinchem/43.3.458
- The paper
- Müller-Bardorff, M., Hallermayer, K., Schröder, A., Ebert, C., Borgya, A., Gerhardt, W., Remppis, A., Zehelein, J., & Katus, H. A. (1997). Improved troponin T ELISA specific for cardiac troponin T isoform: assay development and analytical and clinical validation. Clinical Chemistry. https://doi.org/10.1093/clinchem/43.3.458
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.