CoChat

A Reference Method Laboratory Network for Cholesterol: A Model for Standardization and Improvement of Clinical Laboratory Measurements

Myers, Gary L, Kimberly, Mary M, Waymack, Parvin P, Smith, S Jay, Cooper, Gerald R, Sampson, Eric J · 2000 · Clinical Chemistry
Cited by 160

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: Accurate and precise measurement of blood cholesterol plays a central role in the National Cholesterol Education Program’s strategy to reduce the morbidity and mortality attributable to coronary heart disease. Matrix effects hamper the ability of manufacturers to adequately calibrate and validate traceability to the National Reference System for Cholesterol (NRS/CHOL). CDC created the Cholesterol Reference Method Laboratory Network (CRMLN) to improve cholesterol measurement by assisting manufacturers of in vitro diagnostic products with validation of the traceability of their assays to the NRS/CHOL. Methods: CRMLN laboratories established the CDC cholesterol reference method (modification of the Abell-Levy-Brodie-Kendall chemical method) and are standardized using CDC frozen serum reference materials. CRMLN laboratories use common quality-control materials and participate in monthly external performance evaluations conducted by CDC. The CRMLN performance criteria require member laboratories to agree with CDC within ± 1.0% and maintain a CV ≤2.0%. Results: From 1995 to 2000, the CRMLN laboratories met the accuracy criterion 97% of the time and the precision criterion 99% of the time. During this time period, the CRMLN maintained an average bias to CDC of 0.01% and an average collective CV of 0.33%. Conclusions: CDC established the CRMLN as the first international reference method laboratory network. The CRMLN assists manufacturers in the validation of the calibration of their diagnostic products so that clinical laboratories can measure blood cholesterol more reliably. The CRMLN can serve as a model for other clinical analytes where traceability to a hierarchy of methods is needed and matrix effects of the field methods with processed calibrators or reference materials are present.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/46.11.1762

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 160

Metadata

Authors
Myers, G. L., Kimberly, M. M., Waymack, P. P., Smith, S. J., Cooper, G. R., & Sampson, E. J.
Venue
Clinical Chemistry
Published
2000-11-01
Volume
46
Issue
11
Pages
1762-1772
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1962639155
Cited by
160
References
2
FWCI
4.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Reference Method Laboratory Network for Cholesterol: A Model for Standardization and Improvement of Clinical Laboratory Measurements. https://app.cochat.ai/papers/10.1093/clinchem/46.11.1762
The paper
Myers, G. L., Kimberly, M. M., Waymack, P. P., Smith, S. J., Cooper, G. R., & Sampson, E. J. (2000). A Reference Method Laboratory Network for Cholesterol: A Model for Standardization and Improvement of Clinical Laboratory Measurements. Clinical Chemistry. https://doi.org/10.1093/clinchem/46.11.1762

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.