CoChat

Evaluation of Novel Assays in Clinical Chemistry: Quantification of Plasma Total Homocysteine

Nexo, Ebba, Engbaek, Frode, Ueland, Per Magne, Westby, Christina, O’Gorman, Paudy, Johnston, Carole, Kase, Bengt Frode, Guttormsen, Anne B, Alfheim, Ingrid, McPartlin, Joseph, Smith, David, Møller, Jan, Rasmussen, Karsten, Clarke, Robert, Scott, John M, Refsum, Helga · 2000 · Clinical Chemistry
Cited by 93

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: There is a need for systematic evaluation of methods before their release to the market. We addressed this problem in novel homocysteine assays as part of an European Demonstration Project involving six centers in four countries. Methods: Two immunological methods for measurement of plasma total homocysteine (P-tHcy), the fluorescence polarization immunoassay (FPIA) and the enzyme immunoassay (EIA), were compared with two comparison methods, HPLC and gas chromatography–mass spectrometry (GC-MS). All laboratories performed the following procedures: (a) familiarization; (b) determination of linearity and precision by analyzing five plasma samples with interrelated concentrations for 20 days; (c) correlation using patients’ samples; and (d) assessment of long-term performance. Results: Both immunological methods were linear for P-tHcy between 5 and 45 μmol/L. The intralaboratory imprecision (CV) was <5% for FPIA and <9% for EIA used with a sample processor. The bias was −2% to 3% for FPIA and 2–4% for EIA used with a sample processor. Conclusions: The immunological methods provide results with little bias compared with HPLC and GC-MS. The imprecision of the assays must be considered in the context of their intended use(s).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/46.8.1150

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 93

Metadata

Authors
Nexo, E., Engbaek, F., Ueland, P. M., Westby, C., O’Gorman, P., Johnston, C., Kase, B. F., Guttormsen, A. B., Alfheim, I., McPartlin, J., Smith, D., Møller, J., Rasmussen, K., Clarke, R., Scott, J. M., & Refsum, H.
Venue
Clinical Chemistry
Published
2000-08-01
Volume
46
Issue
8
Pages
1150-1156
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1930359587
Cited by
93
References
2
FWCI
5.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Novel Assays in Clinical Chemistry: Quantification of Plasma Total Homocysteine. https://app.cochat.ai/papers/10.1093/clinchem/46.8.1150
The paper
Nexo, E., Engbaek, F., Ueland, P. M., Westby, C., O’Gorman, P., Johnston, C., Kase, B. F., Guttormsen, A. B., Alfheim, I., McPartlin, J., Smith, D., Møller, J., Rasmussen, K., Clarke, R., Scott, J. M., & Refsum, H. (2000). Evaluation of Novel Assays in Clinical Chemistry: Quantification of Plasma Total Homocysteine. Clinical Chemistry. https://doi.org/10.1093/clinchem/46.8.1150

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.