CoChat

Mean Serum Concentration of Vitamin D-binding Protein (Gc Globulin) Is Related to the Gc Phenotype in Women

Open access
Lauridsen, Anna Lis, Vestergaard, Peter, Nexo, Ebba · 2001 · Clinical Chemistry
Cited by 161

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Abstract

Immunonephelometry has been reported (1) to be a suitable method for quantification of vitamin D-binding protein (also known as Gc globulin or Gc). We wished to develop such a method and examine the association between the mean serum concentration of Gc in women of known Gc phenotype and the phenotype of Gc. Gc is a 52- to 58-kDa multifunctional plasma protein, synthesized mainly by hepatocytes. Polymorphisms in the Gc gene (codominant alleles) give rise to three major electrophoretic variants of Gc (Gc2, Gc1s, and Gc1f), which differ by amino acid substitutions as well as glycosylation (2)(3). The physiological significance related to the various phenotypes is yet to be discovered. Gc is the major carrier protein of vitamin D and its metabolites in the circulation and is important for preservation of the vitamin (4)(5). Gc also transports components such as fatty acids and endotoxin (6)(7), and it is an important player in the actin scavenging system (8)(9). Gc binds actin released from cells upon injury, and the Gc-actin complexes are rapidly cleared from the circulation, thereby preventing the harmful effects of actin filaments in blood vessels. The resulting decrease in Gc concentration makes Gc usable as a prognostic indicator of survival of patients with significant tissue injury after trauma (10) and among patients with hepatic failure (11). In addition to being a transporter and an actin scavenger protein, Gc may be of importance for bone formation and in the immune system. After in vitro removal of its galactose and sialic acid residues, Gc is converted to a very potent macrophage-activating factor, Gc-MAF (12). Administration of Gc-MAF to osteopetrotic rodents reversed their bone and immunological defects, probably by activating osteoclasts as well as macrophages (13). Finally, together with complement factors C5a and C5a des Arg, Gc may act as a co-chemotactic factor in facilitating chemotaxis of neutrophils and monocytes in inflammation (14)(15). Despite the diverse and important roles of Gc, only a few methods for measurement of the protein in serum have been evaluated, and little attention has been paid to possible variation in the serum concentration of Gc as a function of phenotype. We established an immunonephelometric method for quantification of serum Gc, essentially as described previously by Haughton and Mason (1), using a Behring Nephelometer II (Dade Behring) and reagents supplied by Behring (N Reaction Buffer, N Diluent, and N Supplement Reagent Precipitation). Rabbit Anti-Human Gc-Globulin (Dako A/S) was filtered before use (CAMEO 13 N nylonsproejtefilter; Frisenette ApS). We used human lyophilized solid Gc-Globulin Mixed Type (Calbiochem-Novabiochem Corporation) to prepare the calibrator (200 mg/L Gc). Phosphate-buffered saline (pH 7.4; 10 mmol/L PO42−, 145 mmol/L NaCl) was used as the diluent. The Behring Nephelometer II measures the light scattered by antigen-antibody complexes over a fixed period from 7.5 s to 6 min after mixture. We constructed five-point calibration curves, using calibrator dilutions of 1:5–1:80. Assay conditions were as follows: sample volume, 100 μL; sample dilution, 1:20; antibody volume, 30 μL; buffer volume, 80 + 80 μL; volume of N Supplement Reagent Precipitation, 30 μL. The interassay CV for measurement of Gc was 2.6% and 4.6% for 275 and 137 mg/L Gc (n = 22), respectively, as judged from control samples analyzed over a period of 6 months. Sera from two blood donors were used as high (undiluted serum) and low (diluted 1.6:1 with phosphate-buffered saline) controls. To examine whether our method correctly quantified the serum Gc concentration, based on Gc phenotype, we analyzed four serum samples of each homozygous Gc-type, Gc2-2, Gc1s-1s, and Gc1f-1f, in six dilutions, from undiluted to 1:6. Data were subjected to linear regression analysis. The Gc phenotypes behaved alike (P = 0.291). All samples showed a linear relationship between expected and observed concentrations of Gc (P <0.001), and the slopes and intercepts showed only small deviations from 1 and 0. We determined the Gc phenotype of 586 healthy women not taking any hormonal medications [participants of the DOPS study (16) approved by the local ethics committee (no. 1990/1821)]. Because the Gc isoforms produced by different genotypes have different isoelectric points, they can be identified by isoelectric focusing. For that purpose we used Immobiline Dryplate Gels (pH 4.5–5.4) from Pharmacia Biotech. The running conditions were as follows: 10 °C, 3500 V, 5 mA, 15 W, 18–24 h. Gels were stained with Amido Black. Our results for gene frequencies (Gc2, 0.2640; Gc1s, 0.5844; Gc1f, 0.1516) did not differ from those reported in 1981 for a Danish population (n = 1674) (17). Using a z-test, we found P values of 0.63–0.86. We measured the serum Gc concentrations in the 586 women. On the basis of visual inspection of histograms combined with calculation of means ± 4 SD, we decided to exclude two outliers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/47.4.753

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

Metadata

Authors
Lauridsen, A. L., Vestergaard, P., & Nexo, E.
Venue
Clinical Chemistry
Published
2001-04-01
Volume
47
Issue
4
Pages
753-756
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2121212535
Cited by
161
References
25
FWCI
1.87
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.