Analysis of Volatile Disease Markers in Blood
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: The diagnostic potential of breath analysis has been limited by a lack of knowledge on origin, distribution, and metabolism of the exhaled substances. To overcome this problem, we developed a method to assess trace amounts of hydrocarbons (pentane and isoprene), ketones (acetone), halogenated compounds (isoflurane), and thioethers (dimethyl sulfide) in the blood of humans and animals. Methods: Arterial and venous blood samples were taken from mechanically ventilated patients. Additional blood samples were taken from selected vascular compartments of 19 mechanically ventilated pigs. Volatile substances were concentrated by means of solid-phase microextraction (SPME), separated by gas chromatography, and identified by mass spectrometry. Results: Detection limits were 0.02–0.10 nmol/L. Venous concentrations in pigs were 0.2–1.3 nmol/L for isoprene, 0–0.3 nmol/L for pentane, and 1.2–15.1 nmol/L for dimethyl sulfide. In pigs, substances were not equally distributed among vascular compartments. In humans, median arteriovenous concentration differences were 3.58 nmol/L for isoprene and 1.56 nmol/L for pentane. These values were comparable to pulmonary excretion rates reported in the literature. Acute respiratory distress syndrome (ARDS) patients had lower isoprene concentration differences than patients without ARDS. Conclusions: The SPME method can detect volatile substances in very low concentrations in the blood of humans and animals. Analysis of volatile substances in vascular compartments will enlarge the diagnostic potential of breath analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bernard, G. R., Artigas, A., Brigham, K. L., Carlet, J., Falke, K., Hudson, L., Lamy, M., Legall, J. R., Morris, A., & Spragg, R. (1994) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.149.3.7509706 · Cited by 6,746
Cited by
Diagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
Self-citationA review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Amann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Self-citationWang, C., & Sahay, P. (2009) · Sensors · doi:10.3390/s91008230 · Cited by 596
Poli, D., Carbognani, P., Corradi, M., Goldoni, M., Acampa, O., Balbi, B., Bianchi, L., Rusca, M., & Mutti, A. (2005) · Respiratory Research · doi:10.1186/1465-9921-6-71 · Cited by 415
Metadata
- Authors
- Miekisch, W., Schubert, J. K., Vagts, D. A., & Geiger, K.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-06-01
- Volume
- 47
- Issue
- 6
- Pages
- 1053-1060
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2125281746
- Cited by
- 122
- References
- 1
- FWCI
- 2.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).