The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Echocardiographic reference ranges for normal cardiac chamber size: results from the NORRE study
Open accessAbstract
AIMS: Availability of normative reference values for cardiac chamber quantitation is a prerequisite for accurate clinical application of echocardiography. In this study, we report normal reference ranges for cardiac chambers size obtained in a large group of healthy volunteers accounting for gender and age. Echocardiographic data were acquired using state-of-the-art cardiac ultrasound equipment following chamber quantitation protocols approved by the European Association of Cardiovascular Imaging. METHODS: A total of 734 (mean age: 45.8 ± 13.3 years) healthy volunteers (320 men and 414 women) were enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. A comprehensive echocardiographic examination was performed on all subjects following pre-defined protocols. There were no gender differences in age or cholesterol levels. Compared with men, women had significantly smaller body surface areas, and lower blood pressure. Quality of echocardiographic data sets was good to excellent in the majority of patients. Upper and lower reference limits were higher in men than in women. The reference values varied with age. These age-related changes persisted for most parameters after normalization for the body surface area. CONCLUSION: The NORRE study provides useful two-dimensional echocardiographic reference ranges for cardiac chamber quantification. These data highlight the need for body size normalization that should be performed together with age-and gender-specific assessment for the most echocardiographic parameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rudski, L. G., Lai, W. W., Afilalo, J., Hua, L., Handschumacher, M. D., Chandrasekaran, K., Solomon, S. D., Louie, E. K., & Schiller, N. B. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.05.010 · Cited by 7,049
Recommendations for chamber quantification☆
LANG, R., BIERIG, M., DEVEREUX, R., FLACHSKAMPF, F., FOSTER, E., PELLIKKA, P., PICARD, M., ROMAN, M., SEWARD, J., & SHANEWISE, J. (2006) · European Journal of Echocardiography · doi:10.1016/j.euje.2005.12.014 · Cited by 3,571
Self-citationEchocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice
Baumgartner, H., Hung, J., Bermejo, J., Chambers, J. B., Evangelista, A., Griffin, B. P., Iung, B., Otto, C. M., Pellikka, P. A., & Quinones, M. (2009) · European Journal of Echocardiography · doi:10.1093/ejechocard/jen303 · Cited by 967
Dorosz, J. L., Lezotte, D. C., Weitzenkamp, D. A., Allen, L. A., & Salcedo, E. E. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.01.037 · Cited by 427
Kawut, S. M., Lima, J. A. C., Barr, R. G., Chahal, H., Jain, A., Tandri, H., Praestgaard, A., Bagiella, E., Kizer, J. R., Johnson, W. C., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.985515 · Cited by 390
Maffessanti, F., Muraru, D., Esposito, R., Gripari, P., Ermacora, D., Santoro, C., Tamborini, G., Galderisi, M., Pepi, M., & Badano, L. P. (2013) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.113.000706 · Cited by 235
Self-citationDaimon, M., Watanabe, H., Abe, Y., Hirata, K., Hozumi, T., Ishii, K., Ito, H., Iwakura, K., Izumi, C., Matsuzaki, M., et al. (2008) · Circulation Journal · doi:10.1253/circj.cj-08-0171 · Cited by 233
Right Atrial Volume Index in Chronic Systolic Heart Failure and Prognosis
Sallach, J. A., Tang, W. H. W., Borowski, A. G., Tong, W., Porter, T., Martin, M. G., Jasper, S. E., Shrestha, K., Troughton, R. W., & Klein, A. L. (2009) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2009.01.012 · Cited by 173
Peluso, D., Badano, L. P., Muraru, D., Bianco, L. D., Cucchini, U., Kocabay, G., Kovács, A. D., Casablanca, S., & Iliceto, S. (2013) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jet024 · Cited by 172
Self-citationMessika-Zeitoun, D., Bellamy, M., Avierinos, J.-F., Breen, J., Eusemann, C., Rossi, A., Behrenbeck, T., Scott, C., Tajik, J. A., & Enriquez-Sarano, M. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm199 · Cited by 171
Cited by
Lang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.10.003 · Cited by 12,362
Self-citationLang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jev014 · Cited by 8,361
Self-citationPieske, B., Tschöpe, C., de Boer, R. A., Fraser, A. G., Anker, S. D., Donal, E., Edelmann, F., Fu, M., Guazzi, M., Lam, C. S. P., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz641 · Cited by 1,855
Self-citationDeep learning interpretation of echocardiograms
Ghorbani, A., Ouyang, D., Abid, A., He, B., Chen, J. H., Harrington, R. A., Liang, D. H., Ashley, E. A., & Zou, J. Y. (2020) · npj Digital Medicine · doi:10.1038/s41746-019-0216-8 · Cited by 518
Heart failure with mid-range or mildly reduced ejection fraction
Savarese, G., Stolfo, D., Sinagra, G., & Lund, L. H. (2022) · Nature Reviews Cardiology · doi:10.1038/s41569-021-00605-5 · Cited by 476
Metadata
- Authors
- Kou, S., Caballero, L., Dulgheru, R., Voilliot, D., De Sousa, C., Kacharava, G., Athanassopoulos, G. D., Barone, D., Baroni, M., Cardim, N., Gomez De Diego, J. J., Hagendorff, A., Henri, C., Hristova, K., Lopez, T., Magne, J., De La Morena, G., Popescu, B. A., Penicka, M., Ozyigit, T., Rodrigo Carbonero, J. D., Salustri, A., Van De Veire, N., Von Bardeleben, R. S., Vinereanu, D., Voigt, J.-U., Zamorano, J. L., Donal, E., Lang, R. M., Badano, L. P., & Lancellotti, P.
- Venue
- European Heart Journal - Cardiovascular Imaging
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-01-21
- Volume
- 15
- Issue
- 6
- Pages
- 680-690
- ISSN
- 2047-2404 (ISSN-L)
- 2047-2412
- OpenAlex
- W2116118059
- Cited by
- 432
- References
- 20
- FWCI
- 17.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Echocardiographic reference ranges for normal cardiac chamber size: results from the NORRE study. https://app.cochat.ai/papers/10.1093/ehjci/jet284
- The paper
- Kou, S., Caballero, L., Dulgheru, R., Voilliot, D., De Sousa, C., Kacharava, G., Athanassopoulos, G. D., Barone, D., Baroni, M., Cardim, N., Gomez De Diego, J. J., Hagendorff, A., Henri, C., Hristova, K., Lopez, T., Magne, J., De La Morena, G., Popescu, B. A., Penicka, M., . . . Lancellotti, P. (2014). Echocardiographic reference ranges for normal cardiac chamber size: results from the NORRE study. European Heart Journal - Cardiovascular Imaging. https://doi.org/10.1093/ehjci/jet284
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.