CoChat

The utility of handheld echocardiography for early rheumatic heart disease diagnosis: a field study

Open access
Beaton, Andrea, Lu, Jimmy C., Aliku, Twalib, Dean, Peter, Gaur, Lasya, Weinberg, Jacqueline, Godown, Justin, Lwabi, Peter, Mirembe, Grace, Okello, Emmy, Reese, Allison, Shrestha-Astudillo, Ashley, Bradley-Hewitt, Tyler, Scheel, Janet, Webb, Catherine, McCarter, Robert, Ensing, Greg, Sable, Craig · 2015 · European Heart Journal - Cardiovascular Imaging
Cited by 116

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

AIMS: The World Heart Federation (WHF) guidelines for rheumatic heart disease (RHD) are designed for a standard portable echocardiography (STAND) machine. A recent study in a tertiary care centre demonstrated that they also had good sensitivity and specificity when modified for use with handheld echocardiography (HAND). Our study aimed to evaluate the performance of HAND for early RHD diagnosis in the setting of a large-scale field screening. METHODS AND RESULTS: STAND was performed in 4773 children in Gulu, Uganda, with 10% randomly assigned to also undergo HAND. Additionally, any child with mitral or aortic regurgitation also underwent HAND. Studies were performed by experienced echocardiographers and blindly reviewed by cardiologists using 2012 WHF criteria, which were modified slightly for HAND--due to the lack of spectral Doppler capability. Paired echocardiograms were performed in 1420 children (mean age 10.8 and 53% female), resulting in 1234 children who were normal, 133 who met criteria for borderline RHD, 47 who met criteria for definite RHD, and 6 who had other diagnoses. HAND had good sensitivity and specificity for RHD detection (78.9 and 87.2%, respectively), but was most sensitive for definite RHD (97.9%). Inter- and intra-reviewer agreement ranged between 66-83 and 71.4-94.1%, respectively. CONCLUSIONS: HAND has good sensitivity and specificity for diagnosis of early RHD, performing best for definite RHD. Protocols for RHD detection utilizing HAND will need to include confirmation by STAND to avoid over-diagnosis. Strategies that evaluate simplified screening protocols and training of non-physicians hold promise for more wide spread deployment of HAND-based protocols.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ehjci/jeu296

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 116

Metadata

Authors
Beaton, A., Lu, J. C., Aliku, T., Dean, P., Gaur, L., Weinberg, J., Godown, J., Lwabi, P., Mirembe, G., Okello, E., Reese, A., Shrestha-Astudillo, A., Bradley-Hewitt, T., Scheel, J., Webb, C., McCarter, R., Ensing, G., & Sable, C.
Venue
European Heart Journal - Cardiovascular Imaging
Published
2015-01-06
Volume
16
Issue
5
Pages
475-482
ISSN
  • 2047-2404 (ISSN-L)
  • 2047-2412
OpenAlex
W2152717159
Cited by
116
References
1
FWCI
15.20
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The utility of handheld echocardiography for early rheumatic heart disease diagnosis: a field study. https://app.cochat.ai/papers/10.1093/ehjci/jeu296
The paper
Beaton, A., Lu, J. C., Aliku, T., Dean, P., Gaur, L., Weinberg, J., Godown, J., Lwabi, P., Mirembe, G., Okello, E., Reese, A., Shrestha-Astudillo, A., Bradley-Hewitt, T., Scheel, J., Webb, C., McCarter, R., Ensing, G., & Sable, C. (2015). The utility of handheld echocardiography for early rheumatic heart disease diagnosis: a field study. European Heart Journal - Cardiovascular Imaging. https://doi.org/10.1093/ehjci/jeu296

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.