Static and dynamic assessment of myocardial perfusion by computed tomography
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Recent developments in computed tomography (CT) technology have fulfilled the prerequisites for the clinical application of myocardial CT perfusion (CTP) imaging. The evaluation of myocardial perfusion by CT can be achieved by static or dynamic scan acquisitions. Although both approaches have proved clinically feasible, substantial barriers need to be overcome before its routine clinical application. The current review provides an outline of the current status of CTP imaging and also focuses on disparities between static and dynamic CTPs for the evaluation of myocardial blood flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fractional Flow Reserve versus Angiography for Guiding Percutaneous Coronary Intervention
Tonino, P. A. L., De Bruyne, B., Pijls, N. H. J., Siebert, U., Ikeno, F., van `t Veer, M., Klauss, V., Manoharan, G., Engstrøm, T., Oldroyd, K. G., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0807611 · Cited by 4,260
Coronary Microvascular Dysfunction
Camici, P. G., & Crea, F. (2007) · New England Journal of Medicine · doi:10.1056/nejmra061889 · Cited by 1,605
Coronary Microvascular Dysfunction
Crea, F., Lanza, G. A., & Camici, P. G. (2014) · Springer eBooks · doi:10.1007/978-88-470-5367-0 · Cited by 1,287
Angiographic Versus Functional Severity of Coronary Artery Stenoses in the FAME Study
Tonino, P. A. L., Fearon, W. F., De Bruyne, B., Oldroyd, K. G., Leesar, M. A., Ver Lee, P. N., MacCarthy, P. A., van't Veer, M., & Pijls, N. H. J. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.096 · Cited by 1,271
Radiation Dose to Patients From Cardiac Diagnostic Imaging
Einstein, A. J., Moser, K. W., Thompson, R. C., Cerqueira, M. D., & Henzlova, M. J. (2007) · Circulation · doi:10.1161/circulationaha.107.688101 · Cited by 806
Comprehensive Assessment of Coronary Artery Stenoses
Meijboom, W. B., Van Mieghem, C. A. G., van Pelt, N., Weustink, A., Pugliese, F., Mollet, N. R., Boersma, E., Regar, E., van Geuns, R. J., de Jaegere, P. J., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.05.024 · Cited by 637
Effects of Sex on Coronary Microvascular Dysfunction and Cardiac Outcomes
Murthy, V. L., Naya, M., Taqueti, V. R., Foster, C. R., Gaber, M., Hainer, J., Dorbala, S., Blankstein, R., Rimoldi, O., Camici, P. G., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.008507 · Cited by 618
Long-Term Prognostic Value of 13N-Ammonia Myocardial Perfusion Positron Emission Tomography
Herzog, B. A., Husmann, L., Valenta, I., Gaemperli, O., Siegrist, P. T., Tay, F. M., Burkhard, N., Wyss, C. A., & Kaufmann, P. A. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.02.069 · Cited by 616
Ziadi, M. C., deKemp, R. A., Williams, K. A., Guo, A., Chow, B. J. W., Renaud, J. M., Ruddy, T. D., Sarveswaran, N., Tee, R. E., & Beanlands, R. S. B. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.01.065 · Cited by 606
Rochitte, C. E., George, R. T., Chen, M. Y., Arbab‐Zadeh, A., Dewey, M., Miller, J. M., Niinuma, H., Yoshioka, K., Kitagawa, K., Nakamori, S., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht488 · Cited by 462
Takx, R. A. P., Blomberg, B. A., Aidi, H. E., Habets, J., de Jong, P. A., Nagel, E., Hoffmann, U., & Leiner, T. (2015) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.114.002666 · Cited by 427
Muirhead, C. R., O'Hagan, J. A., Haylock, R. G. E., Phillipson, M. A., Willcock, T., Berridge, G. L. C., & Zhang, W. (2009) · British Journal of Cancer · doi:10.1038/sj.bjc.6604825 · Cited by 423
George, R. T., Arbab-Zadeh, A., Miller, J. M., Kitagawa, K., Chang, H.-J., Bluemke, D. A., Becker, L., Yousuf, O., Texter, J., Lardo, A. C., et al. (2009) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.108.813766 · Cited by 324
Myocardial blood flow measurement by PET: technical aspects and clinical applications.
Kaufmann, P. A., & Camici, P. G. (2005) · PubMed · Cited by 311
Gaemperli, O., Schepis, T., Valenta, I., Koepfli, P., Husmann, L., Scheffel, H., Leschka, S., Eberli, F. R., Luscher, T. F., Alkadhi, H., et al. (2008) · Radiology · doi:10.1148/radiol.2482071307 · Cited by 213
Ko, B. S., Cameron, J. D., Meredith, I. T., Leung, M., Antonis, P. R., Nasis, A., Crossett, M., Hope, S. A., Lehman, S. J., Troupis, J., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr268 · Cited by 199
Shreibati, J. B., Baker, L. C., & Hlatky, M. A. (2011) · JAMA · doi:10.1001/jama.2011.1652 · Cited by 193
George, R. T., Arbab-Zadeh, A., Miller, J. M., Vavere, A. L., Bengel, F. M., Lardo, A. C., & Lima, J. A. C. (2012) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.111.969303 · Cited by 183
Feuchtner, G. M., Goetti, R. P., Plass, A., Wieser, M., Scheffel, H., Wyss, C. A., Stolzmann, P., Donati, O. F., Schnabl, J., Falk, V., et al. (2011) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.110.961250 · Cited by 154
Ko, B. S. H., Cameron, J. D., Leung, M., Meredith, I. T., Leong, D. P., Antonis, P. R., Crossett, M. P., Troupis, J. M., Harper, R. W., Malaiapan, Y. R., et al. (2012) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2012.09.004 · Cited by 148
Berman, D. S., Hachamovitch, R., Shaw, L. J., Friedman, J. D., Hayes, S. W., Thomson, L., Fieno, D. S., Germano, G., Wong, N. D., Kang, X., et al. (2006) · PubMed · Cited by 139
Cury, R. C., Magalhães, T. A., Borges, A. C., Shiozaki, A. A., Lemos, P. A., Júnior, J. S., Meneghetti, J. C., Cury, R. C., & Rochitte, C. E. (2010) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2010.03.025 · Cited by 124
Stress Myocardial CT Perfusion
Techasith, T., & Cury, R. C. (2011) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2011.04.017 · Cited by 114
Greif, M., von Ziegler, F., Bamberg, F., Tittus, J., Schwarz, F., D’Anastasi, M., Marcus, R. P., Schenzle, J. C., Becker, C. R., Nikolaou, K., et al. (2013) · Heart · doi:10.1136/heartjnl-2013-303794 · Cited by 107
The Effects of Medications on Myocardial Perfusion
Zoghbi, G. J., Dorfman, T. A., & Iskandrian, A. E. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.04.035 · Cited by 103
Stuijfzand, W. J., Uusitalo, V., Kero, T., Danad, I., Rijnierse, M. T., Saraste, A., Raijmakers, P. G. H. M., Lammertsma, A. A., Harms, H., Heymans, M. W., et al. (2015) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.114.002400 · Cited by 91
Self-citationCury, R. C., Kitt, T. M., Feaheny, K., Blankstein, R., Ghoshhajra, B. B., Budoff, M. J., Leipsic, J. A., Min, J. K., Akin, J., & George, R. T. (2015) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2015.01.002 · Cited by 82
Self-citationKono, A. K., Coenen, A., Lubbers, M. M., Kurata, A., Rossi, A., Dharampal, A. S., Dijkshoorn, M. L., van Geuns, R., Krestin, G. P., & Nieman, K. (2014) · Investigative Radiology · doi:10.1097/rli.0000000000000087 · Cited by 79
Danad, I., Raijmakers, P. G. H. M., Appelman, Y., Harms, H. J., de Haan, S., van den Oever, M. L. P., van Kuijk, C., Allaart, C. P., Hoekstra, O. S., Lammertsma, A. A., et al. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1956-0 · Cited by 77
Self-citationApplications of cardiac multidetector CT beyond coronary angiography
Schuleri, K. H., George, R. T., & Lardo, A. C. (2009) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2009.172 · Cited by 69
Ollendorf, D. A., Kuba, M., & Pearson, S. D. (2010) · Journal of General Internal Medicine · doi:10.1007/s11606-010-1556-x · Cited by 28
Quantitative and qualitative analysis and interpretation of CT perfusion imaging
Valdiviezo, C., Ambrose, M., Mehra, V. C., Lardo, A. C., Lima, J. A. C., & George, R. T. (2010) · Journal of Nuclear Cardiology · doi:10.1007/s12350-010-9291-6 · Cited by 26
Kim, E. Y., Chung, W., Sung, Y. M., Byun, S. S., Park, J. H., Kim, J. H., & Moon, J. (2014) · International journal of cardiac imaging · doi:10.1007/s10554-014-0432-x · Cited by 24
Cited by
Narula, J., Chandrashekhar, Y., Ahmadi, A., Abbara, S., Berman, D. S., Blankstein, R., Leipsic, J., Newby, D., Nicol, E. D., Nieman, K., et al. (2021) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2020.11.001 · Cited by 398
Coronary Microvascular Dysfunction
Vancheri, F., Longo, G., Vancheri, S., & Henein, M. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9092880 · Cited by 321
Coronary Computed Tomographic Angiography for Complete Assessment of Coronary Artery Disease
Serruys, P. W., Hara, H., Garg, S., Kawashima, H., Nørgaard, B. L., Dweck, M. R., Bax, J. J., Knuuti, J., Nieman, K., Leipsic, J. A., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.06.019 · Cited by 208
Inflammation in Coronary Microvascular Dysfunction
Sagris, M., Theofilis, P., Antonopoulos, A. S., Oikonomou, E., Paschaliori, C., Galiatsatos, N., Tsioufis, K., & Tousoulis, D. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms222413471 · Cited by 115
Metadata
- Authors
- Danad, I., Szymonifka, J., Schulman-Marcus, J., & Min, J. K.
- Venue
- European Heart Journal – Cardiovascular Imaging
- Publisher
- Oxford University Press (OUP)
- Published
- 2016-03-24
- Volume
- 17
- Issue
- 8
- Pages
- 836-844
- ISSN
- 2047-2404 (ISSN-L)
- 2047-2412
- OpenAlex
- W2311405503
- Cited by
- 162
- References
- 33
- FWCI
- 16.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.