Improving explainability of deep neural network-based electrocardiogram interpretation using variational auto-encoders
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Aims: Deep neural networks (DNNs) perform excellently in interpreting electrocardiograms (ECGs), both for conventional ECG interpretation and for novel applications such as detection of reduced ejection fraction (EF). Despite these promising developments, implementation is hampered by the lack of trustworthy techniques to explain the algorithms to clinicians. Especially, currently employed heatmap-based methods have shown to be inaccurate. Methods and results: We present a novel pipeline consisting of a variational auto-encoder (VAE) to learn the underlying factors of variation of the median beat ECG morphology (the FactorECG), which are subsequently used in common and interpretable prediction models. As the ECG factors can be made explainable by generating and visualizing ECGs on both the model and individual level, the pipeline provides improved explainability over heatmap-based methods. By training on a database with 1.1 million ECGs, the VAE can compress the ECG into 21 generative ECG factors, most of which are associated with physiologically valid underlying processes. Performance of the explainable pipeline was similar to ‘black box’ DNNs in conventional ECG interpretation [area under the receiver operating curve (AUROC) 0.94 vs. 0.96], detection of reduced EF (AUROC 0.90 vs. 0.91), and prediction of 1-year mortality (AUROC 0.76 vs. 0.75). Contrary to the ‘black box’ DNNs, our pipeline provided explainability on which morphological ECG changes were important for prediction. Results were confirmed in a population-based external validation dataset. Conclusions: Future studies on DNNs for ECGs should employ pipelines that are explainable to facilitate clinical implementation by gaining confidence in artificial intelligence and making it possible to identify biased models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rudin, C. (2019) · Nature Machine Intelligence · doi:10.1038/s42256-019-0048-x · Cited by 10,561 · cited 5×
“most algorithms, and the limitations of current post hoc explainability methods, the association between input and output remains unexplainable to humans.(8) The lack of interpretability makes it difficult for clinicians to gain enough confidence to make clinical decisions based on these algorithms, and more important…”
BackgroundInfluentialXGBoost: A Scalable Tree Boosting System
Chen, T., & Guestrin, C. (2016) · arXiv · doi:10.48550/arxiv.1603.02754 · Cited by 7,104
Collins, G. S., Reitsma, J. B., Altman, D. G., & Moons, K. G. M. (2015) · Annals of Internal Medicine · doi:10.7326/m14-0697 · Cited by 3,267
Hannun, A. Y., Rajpurkar, P., Haghpanahi, M., Tison, G. H., Bourn, C., Turakhia, M. P., & Ng, A. Y. (2019) · Nature Medicine · doi:10.1038/s41591-018-0268-3 · Cited by 3,148
European Union Regulations on Algorithmic Decision Making and a “Right to Explanation”
Goodman, B., & Flaxman, S. (2017) · AI Magazine · doi:10.1609/aimag.v38i3.2741 · Cited by 2,131 · cited 1×
“These issues have already been acknowledged by the new European Union’s General Data Protection Regulation, which requires a ‘right to explanation’ for AI algorithms.(9) To improve explainability, several post hoc explainability methods have been proposed, usually by providing heatmaps on top of the ECG.”
MethodThe false hope of current approaches to explainable artificial intelligence in health care
Ghassemi, M., Oakden-Rayner, L., & Beam, A. L. (2021) · The Lancet Digital Health · doi:10.1016/s2589-7500(21)00208-9 · Cited by 1,724 · cited 2×
“Despite these promising developments, clinical implementation is severely hampered by the lack of trustworthy techniques to explain the decisions of the algorithm to clinicians.(6,7) Due to the ‘black box’ nature of”
BackgroundMethodAttia, Z. I., Kapa, S., Lopez-Jimenez, F., McKie, P. M., Ladewig, D. J., Satam, G., Pellikka, P. A., Enriquez-Sarano, M., Noseworthy, P. A., Munger, T. M., et al. (2019) · Nature Medicine · doi:10.1038/s41591-018-0240-2 · Cited by 1,389 · cited 6×
“%) and predict 1-year mortality, we selected patients using the same approaches as Attia et al.4 and Raghunath et al.,5 respectively.”
BackgroundMethodResultInfluentialSanity Checks for Saliency Maps
Adebayo, J., Gilmer, J., Muelly, M., Goodfellow, I., Hardt, M., & Kim, B. (2018) · arXiv · doi:10.48550/arxiv.1810.03292 · Cited by 1,294 · cited 2×
“Finally, recent studies have shown that saliency-based methods can be very unreliable in providing consequent annotations and can also show reassuring saliency maps when a model is completely untrained, stressing the need for better approaches to explain the output of DNNs.(8,12,13) Therefore, instead of explaining th…”
BackgroundUK Biobank's cardiovascular magnetic resonance protocol
Petersen, S. E., Matthews, P. M., Francis, J. M., Robson, M. D., Zemrak, F., Boubertakh, R., Young, A. A., Hudson, S., Weale, P., Garratt, S., et al. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-016-0227-4 · Cited by 481 · cited 1×
“Only individuals where the left ventricular EF was determined on the CMR using a manual analysis protocol by Petersen et al.16,17 were included (UK Biobank return number 2541).”
MethodAI in medicine must be explainable
Kundu, S. (2021) · Nature Medicine · doi:10.1038/s41591-021-01461-z · Cited by 318 · cited 1×
“Despite these promising developments, clinical implementation is severely hampered by the lack of trustworthy techniques to explain the decisions of the algorithm to clinicians.(6,7) Due to the ‘black box’ nature of”
Method
Cited by
Artificial intelligence and the electrocardiogram: A modern renaissance
Palermi, S., Vecchiato, M., Ng, F. S., Attia, Z., Cho, Y., Anselmino, M., De Ferrari, G. M., Saglietto, A., Sau, A., Chiu, I.-M., et al. (2025) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2025.04.036 · Cited by 42
Liang, Y., Sau, A., Zeidaabadi, B., Barker, J., Patlatzoglou, K., Pastika, L., Sieliwonczyk, E., Whinnett, Z., Peters, N. S., Yu, Z., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf448 · Cited by 26
König, S., Hohenstein, S., Nitsche, A., Pellissier, V., Leiner, J., Stellmacher, L., Hindricks, G., & Bollmann, A. (2024) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztad081 · Cited by 21
“32,33 Direct comparisons between the two groups of models for the ECG-based detection of LVSD are currently lacking.”
Background
Metadata
- Authors
- van de Leur, R. R., Bos, M. N., Taha, K., Sammani, A., Yeung, M. W., van Duijvenboden, S., Lambiase, P. D., Hassink, R. J., van der Harst, P., Doevendans, P. A., Gupta, D. K., & van Es, R.
- Venue
- European Heart Journal - Digital Health
- Publisher
- Oxford University Press (OUP)
- Published
- 2022-07-25
- Volume
- 3
- Issue
- 3
- Pages
- 390-404
- ISSN
- 2634-3916 (ISSN-L)
- OpenAlex
- W4287578511
- Cited by
- 77
- References
- 13
- FWCI
- 8.79
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.