Effect of two types of mandibular advancement splints on snoring and obstructive sleep apnoea
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Snoring and obstructive sleep apnoea (OSA) both seem at least to be associated with narrowing of the upper airway and sleep-induced loss of muscle-tone. Mandibular advancement splints (MAS) have been proposed as a relatively simple method to increase oro- and hypo-pharyngeal dimensions thereby increasing the size of the airway. However, data on their effectiveness are conflicting and there are no clear indications as to which design is most effective or when they should be used. The effects of two designs of splint (types A and B) have been evaluated in 14 and nine subjects, respectively, using the Epworth Sleepiness Score (ESS) and domiciliary sleep monitoring on separate nights. Both splints reduced the median ESS (type A from 12 to 4.5; P = 0.003, type B from 7 to 4; P = 0.005). The apnoea-hypopnoea index was not affected by type A, but was reduced from 7.1 to 0.8; P = 0.005 by type B splints. There was evidence of a small improvement in overnight oxygen saturation for type B splints (P = 0.02). The splints were well tolerated and continued to be used nightly by 18 subjects. Mandibular advancement splints may offer a simple and effective alternative for the treatment of snoring and mild OSA in selected patients. Splint design may have considerable bearing on efficacy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Predictors and prevalence of obstructive sleep apnoea and snoring in 1001 middle aged men.
Stradling, J. R., & Crosby, J. H. (1991) · Thorax · doi:10.1136/thx.46.2.85 · Cited by 640
Cited by
Oral Appliances for Snoring and Obstructive Sleep Apnea: A Review
Ferguson, K. A., Cartwright, R., Rogers, R., & Schmidt-Nowara, W. (2006) · Sleep · doi:10.1093/sleep/29.2.244 · Cited by 687
Oral appliances for obstructive sleep apnoea
Lim, J., Lasserson, T. J., Fleetham, J., & Wright, J. J. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004435.pub3 · Cited by 418
Review of oral appliances for treatment of sleep-disordered breathing
Hoffstein, V. (2007) · Sleep and Breathing · doi:10.1007/s11325-006-0084-8 · Cited by 355
Engleman, H. M., McDonald, J. P., Graham, D., Lello, G. E., Kingshott, R. N., Coleman, E. L., Mackay, T. W., & Douglas, N. J. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2109023 · Cited by 289
Villa, M. P., Bernkopf, E., Pagani, J., Broia, V., Montesano, M., & Ronchetti, R. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.1.2011031 · Cited by 233
Hoekema, A., Stegenga, B., & de Bont, L. G. M. (2004) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/154411130401500303 · Cited by 195
Rose, E. (2002) · The European Journal of Orthodontics · doi:10.1093/ejo/24.2.191 · Cited by 132
Lawton, H. M. (2005) · The European Journal of Orthodontics · doi:10.1093/ejo/cjh067 · Cited by 127
Oral appliances and functional orthopaedic appliances for obstructive sleep apnoea in children
Carvalho, F. R., Lentini-Oliveira, D. A., Prado, L. B., Prado, G. F., & Carvalho, L. B. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005520.pub3 · Cited by 127
Gauthier, L., Laberge, L., Beaudry, M., Laforte, M., Rompré, P. H., & Lavigne, G. J. (2009) · Sleep Medicine · doi:10.1016/j.sleep.2008.03.011 · Cited by 115
Nazarali, N., Altalibi, M., Nazarali, S., Major, M. P., Flores-Mir, C., & Major, P. W. (2015) · The European Journal of Orthodontics · doi:10.1093/ejo/cju101 · Cited by 62
Metadata
- Authors
- Lamont, J.
- Venue
- The European Journal of Orthodontics
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-06-01
- Volume
- 20
- Issue
- 3
- Pages
- 293-297
- ISSN
- 0141-5387 (ISSN-L)
- 1460-2210
- OpenAlex
- W2161305423
- Cited by
- 54
- References
- 1
- FWCI
- 0.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.