Prevalence and outcome of dual aortic stenosis and cardiac amyloid pathology in patients referred for transcatheter aortic valve implantation
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Aims: Cardiac amyloidosis is common in elderly patients with aortic stenosis (AS) referred for transcatheter aortic valve implantation (TAVI). We hypothesized that patients with dual aortic stenosis and cardiac amyloid pathology (AS-amyloid) would have different baseline characteristics, periprocedural and mortality outcomes. Methods and results: Patients aged ≥75 with severe AS referred for TAVI at two sites underwent blinded bone scintigraphy prior to intervention (Perugini Grade 0 negative, 1–3 increasingly positive). Baseline assessment included echocardiography, electrocardiogram (ECG), blood tests, 6-min walk test, and health questionnaire, with periprocedural complications and mortality follow-up. Two hundred patients were recruited (aged 85 ± 5 years, 50% male). AS-amyloid was found in 26 (13%): 8 Grade 1, 18 Grade 2. AS-amyloid patients were older (88 ± 5 vs. 85 ± 5 years, P = 0.001), with reduced quality of life (EQ-5D-5L 50 vs. 65, P = 0.04). Left ventricular wall thickness was higher (14 mm vs. 13 mm, P = 0.02), ECG voltages lower (Sokolow–Lyon 1.9 ± 0.7 vs. 2.5 ± 0.9 mV, P = 0.03) with lower voltage/mass ratio (0.017 vs. 0.025 mV/g/m2, P = 0.03). High-sensitivity troponin T and N-terminal pro-brain natriuretic peptide were higher (41 vs. 21 ng/L, P < 0.001; 3702 vs. 1254 ng/L, P = 0.001). Gender, comorbidities, 6-min walk distance, AS severity, prevalence of disproportionate hypertrophy, and post-TAVI complication rates (38% vs. 35%, P = 0.82) were the same. At a median follow-up of 19 (10–27) months, there was no mortality difference (P = 0.71). Transcatheter aortic valve implantation significantly improved outcome in the overall population (P < 0.001) and in those with AS-amyloid (P = 0.03). Conclusions: AS-amyloid is common and differs from lone AS. Transcatheter aortic valve implantation significantly improved outcome in AS-amyloid, while periprocedural complications and mortality were similar to lone AS, suggesting that TAVI should not be denied to patients with AS-amyloid.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.10.003 · Cited by 12,362
Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O’Gara, P. T., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.176857 · Cited by 8,495
Lang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jev014 · Cited by 8,361 · cited 1×
“Relative wall thickness was defined as: (2 posterior wall thickness)/(LV internal diameter at end-diastole).(22) Left ventricular mass was calculated using the formula from Devereux et al.”
MethodTranscatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Echocardiographic assessment of left ventricular hypertrophy: Comparison to necropsy findings
Devereux, R. B., Alonso, D. R., Lutas, E. M., Gottlieb, G. J., Campo, E., Sachs, I., & Reichek, N. (1986) · The American Journal of Cardiology · doi:10.1016/0002-9149(86)90771-x · Cited by 6,229 · cited 2×
“Relative wall thickness was defined as: (2 posterior wall thickness)/(LV internal diameter at end-diastole).22 Left ventricular mass was calculated using the formula from Devereux et al.23: LV mass ¼ 0:8 x 1:04 x ½ðIVSdþ LVIDdþ PWdÞ3– LVIDd3 þ 0:6 Where IVSd is the interventricular septal diameter, LVIDd is the left v…”
MethodNagueh, S. F., Smiseth, O. A., Appleton, C. P., Byrd, B. F., Dokainish, H., Edvardsen, T., Flachskampf, F. A., Gillebert, T. C., Klein, A. L., Lancellotti, P., et al. (2016) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2016.01.011 · Cited by 5,262
Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients
Leon, M. B., Smith, C. R., Mack, M. J., Makkar, R. R., Svensson, L. G., Kodali, S. K., Thourani, V. H., Tuzcu, E. M., Miller, D. C., Herrmann, H. C., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1514616 · Cited by 5,053 · cited 1×
“In the 149 (75%) patients who underwent TAVI (16 AS-amyloid, 133 lone AS), complication rates were equivalent to published international trials.(8,15) Using strict criteria and capturing all major and minor events via VARC-2, complications occurred at the same rate in AS-amyloid, P = 0.”
ResultTranscatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients
Mack, M. J., Leon, M. B., Thourani, V. H., Makkar, R., Kodali, S. K., Russo, M., Kapadia, S. R., Malaisrie, S. C., Cohen, D. J., Pibarot, P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1814052 · Cited by 4,847 · cited 1×
“Transcatheter aortic valve implantation numbers are increasing worldwide, a trend that is likely to continue due both to the ageing population and the expanding role of the procedure itself to include intermediate(8) and even low-risk populations.(9) Cardiac amyloidosis (CA) is also common, particularly in elderly mal…”
BackgroundKappetein, A. P., Head, S. J., Généreux, P., Piazza, N., Mieghem, N. M. V., Blackstone, E., Brott, T., Cohen, D., Cutlip, D. E., van Es, G., et al. (2012) · doi:10.48350/15011 · Cited by 3,368
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000031 · Cited by 2,905
Cited by
Kittleson, M. M., Ruberg, F. L., Ambardekar, A. V., Brannagan, T. H., Cheng, R. K., Clarke, J. O., Dember, L. M., Frantz, J. G., Hershberger, R. E., Maurer, M. S., et al. (2023) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2022.11.022 · Cited by 640
Prevalence and Outcomes of Concomitant Aortic Stenosis and Cardiac Amyloidosis
Nitsche, C., Scully, P. R., Patel, K. P., Kammerlander, A. A., Koschutnik, M., Dona, C., Wollenweber, T., Ahmed, N., Thornton, G. D., Kelion, A. D., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.11.006 · Cited by 377
Self-citationATTR Amyloidosis: Current and Emerging Management Strategies
Griffin, J. M., Rosenthal, J. L., Grodin, J. L., Maurer, M. S., Grogan, M., & Cheng, R. K. (2021) · JACC: CardioOncology · doi:10.1016/j.jaccao.2021.06.006 · Cited by 167
“Surgical and percutaneous data are limited in ATTR-CA, although several studies have demonstrated that TAVR has acceptable outcomes and should not be withheld for this patient population (5,49,57,58).”
BackgroundMethodRNA-targeting and gene editing therapies for transthyretin amyloidosis
Aimo, A., Castiglione, V., Rapezzi, C., Franzini, M., Panichella, G., Vergaro, G., Gillmore, J., Fontana, M., Passino, C., & Emdin, M. (2022) · Nature Reviews Cardiology · doi:10.1038/s41569-022-00683-z · Cited by 163
Self-citationMulti-modality imaging in aortic stenosis: an EACVI clinical consensus document
Dweck, M. R., Loganath, K., Bing, R., Treibel, T. A., McCann, G. P., Newby, D. E., Leipsic, J., Fraccaro, C., Paolisso, P., Cosyns, B., et al. (2023) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jead153 · Cited by 79
Self-citationChronological vs Biological Age in Interventional Cardiology
Damluji, A. A., Nanna, M. G., Rymer, J., Kochar, A., Lowenstern, A., Baron, S. J., Narins, C. R., & Alkhouli, M. (2024) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2024.01.284 · Cited by 53
Damluji, A. A., Bernacki, G., Afilalo, J., Lyubarova, R., Orkaby, A. R., Kwak, M. J., Hummel, S., Kirkpatrick, J. N., Maurer, M. S., Wenger, N., et al. (2024) · JACC: Advances · doi:10.1016/j.jacadv.2024.100877 · Cited by 41
Metadata
- Authors
- Scully, P. R., Patel, K. P., Treibel, T. A., Thornton, G. D., Hughes, R. K., Chadalavada, S., Katsoulis, M., Hartman, N., Fontana, M., Pugliese, F., Sabharwal, N., Newton, J. D., Kelion, A., Ozkor, M., Kennon, S., Mullen, M., Lloyd, G., Menezes, L. J., Hawkins, P. N., & Moon, J. C.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2020-04-08
- Volume
- 41
- Issue
- 29
- Pages
- 2759-2767
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W3014239122
- Cited by
- 202
- References
- 37
- FWCI
- 9.13
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.