Different spectral components of 24 h heart rate variability are related to different modes of death in chronic heart failure
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
AIMS: To assess whether analysis of heart rate variability (HRV) from 24 h Holter recordings provides information about the mode of death (pump failure vs. sudden death) in chronic heart failure (CHF). METHODS AND RESULTS: We analysed 24 h HRV in 330 consecutive CHF patients in sinus rhythm. Indices derived from time domain, spectral domain, and fractal analyses of 24 h automatic HRV were evaluated. Data from clinical assessment, echocardiography, right heart catheterization, exercise test, blood biochemical examination, and arrhythmia pattern were analysed. Patients were followed up for 3 years. Two simple multivariable models, both including 24 h spectral indices, were able to identify patients at higher risk of progressive pump failure and sudden death, respectively. Depressed power of night-time HRV (< or = 509 ms(2)) below 0.04 Hz [very low frequency (VLF)], high pulmonary wedge pressure (PWP > or = 18 mm Hg) and low left ventricular ejection fraction (LVEF < or = 24%) were independently related to death for progressive pump failure, while the reduction of power between 0.04 and 0.15 Hz at night (LF < or = 20 ms(2)) and increased left ventricular end-systolic diameter (LVESD > or = 61 mm) were linked to sudden mortality. CONCLUSION: Automatic spectral analysis of 24 h HRV provides independent risk indices related to mode of death in sinus rhythm CHF patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Self-citationCardiovascular neural regulation explored in the frequency domain.
Malliani, A., Pagani, M., Lombardi, F., & Cerutti, S. (1991) · Circulation · doi:10.1161/01.cir.84.2.482 · Cited by 3,569
Self-citationHjalmarson, Å., Goldstein, S., Fagerberg, B., Wedel, H., Waagstein, F., Kjekshus, J., Wikstrand, J., El Allaf, D., Vítovec, J., Aldershvile, J., et al. (2000) · JAMA · doi:10.1001/jama.283.10.1295 · Cited by 1,399
Nolan, J., Batin, P. D., Andrews, R., Lindsay, S. J., Brooksby, P., Mullen, M., Baig, W., Flapan, A. D., Cowley, A., Prescott, R. J., et al. (1998) · Circulation · doi:10.1161/01.cir.98.15.1510 · Cited by 1,179
La Rovere, M. T., Pinna, G. D., Maestri, R., Mortara, A., Capomolla, S., Febo, O., Ferrari, R., Franchini, M., Gnemmi, M., Opasich, C., et al. (2003) · Circulation · doi:10.1161/01.cir.0000047275.25795.17 · Cited by 917
Self-citationGrimm, W., Christ, M., Bach, J., Müller, H.-H., & Maisch, B. (2003) · Circulation · doi:10.1161/01.cir.0000100721.52503.85 · Cited by 321
Cited by
Sassi, R., Cerutti, S., Lombardi, F., Malik, M., Huikuri, H. V., Peng, C.-K., Schmidt, G., Yamamoto, Y., Reviewers:, D., Gorenek, B., et al. (2015) · Europace · doi:10.1093/europace/euv015 · Cited by 727
Analysis of First-Derivative Based QRS Detection Algorithms
Arzeno, N. M., Deng, Z.-D., & Poon, C.-S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912658 · Cited by 413
Zannad, F., De Ferrari, G. M., Tuinenburg, A. E., Wright, D., Brugada, J., Butter, C., Klein, H., Stolen, C., Meyer, S., Stein, K. M., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehu345 · Cited by 380
Lu, G., Yang, F., Taylor, J. A., & Stein, J. F. (2009) · Journal of Medical Engineering & Technology · doi:10.3109/03091900903150998 · Cited by 324
Fang, S.-C., Wu, Y.-L., & Tsai, P.-S. (2020) · Biological Research For Nursing · doi:10.1177/1099800419877442 · Cited by 302
Metadata
- Authors
- Guzzetti, S., Rovere, M. T. L., Pinna, G. D., Maestri, R., Borroni, E., Porta, A., Mortara, A., & Malliani, A.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-12-09
- Volume
- 26
- Issue
- 4
- Pages
- 357-362
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2110283949
- Cited by
- 172
- References
- 6
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Different spectral components of 24 h heart rate variability are related to different modes of death in chronic heart failure. https://app.cochat.ai/papers/10.1093/eurheartj/ehi067
- The paper
- Guzzetti, S., Rovere, M. T. L., Pinna, G. D., Maestri, R., Borroni, E., Porta, A., Mortara, A., & Malliani, A. (2005). Different spectral components of 24 h heart rate variability are related to different modes of death in chronic heart failure. European Heart Journal. https://doi.org/10.1093/eurheartj/ehi067
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.