The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
A comparison of photoplethysmography and ECG recording to analyse heart rate variability in healthy subjects
Abstract
Measures of heart rate variability (HRV) are widely used to assess autonomic nervous system (ANS) function. The signal from which they are derived requires accurate determination of the interval between successive heartbeats; it can be recorded via electrocardiography (ECG), which is both non-invasive and widely available. However, methodological problems inherent in the recording and analysis of ECG traces have motivated a search for alternatives. Photoplethysmography (PPG) constitutes another means of determining the timing of cardiac cycles via continuous monitoring of changes in blood volume in a portion of the peripheral microvasculature. This technique measures pulse waveforms, which in some instances may prove a practical basis for HRV analysis. We investigated the feasibility of using earlobe PPG to analyse HRV by applying the same analytic process to PPG and ECG recordings made simultaneously. Comparison of 5-minute recordings demonstrated a very high degree of correlation in the temporal and frequency domains and in nonlinear dynamic analyses between HRV measures derived from PPG and ECG. Our results confirm that PPG provides accurate interpulse intervals from which HRV measures can be accurately derived in healthy subjects under ideal conditions, suggesting this technique may prove a practical alternative to ECG for HRV analysis. This finding is of particular relevance to the care of patients suffering from peripheral hyperkinesia or tremor, which make fingertip PPG recording impractical, and following clinical interventions known to introduce electrical artefacts into the electrocardiogram.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
The Value of Cardiovascular Autonomic Function Tests: 10 Years Experience in Diabetes
Ewing, D. J., Martyn, C. N., Young, R. J., & Clarke, B. F. (1985) · Diabetes Care · doi:10.2337/diacare.8.5.491 · Cited by 1,434
Do existing measures of Poincaré plot geometry reflect nonlinear features of heart rate variability
Brennan, M., Palaniswami, M., & Kamen, P. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.959330 · Cited by 1,044
Hon, E. H., & Lee, S. T. (1963) · PubMed · Cited by 381
American journal of obstetrics & gynecology
Gynecologists (1920) · Cited by 355
Selvaraj, N., Jaryal, A., Santhosh, J., Deepak, K. K., & Anand, S. (2008) · Journal of Medical Engineering & Technology · doi:10.1080/03091900701781317 · Cited by 342
Skin photoplethysmography — a review
Kamal, A. A. R., Harness, J. B., Irving, G., & Mearns, A. J. (1989) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(89)90159-4 · Cited by 328
Sampling frequency of the electrocardiogram for spectral analysis of the heart rate variability
Merri, M., Farden, D. C., Mottley, J. G., & Titlebaum, E. L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43621 · Cited by 248
Photoelectric Plethysmography of the Fingers and Toes in Man
Hertzman, A. B. (1937) · Experimental Biology and Medicine · doi:10.3181/00379727-37-9630 · Cited by 210
The Effects of Motion on the Performance of Pulse Oximeters in Volunteers (Revised publication)
Barker, S. J., & Shah, N. K. (1997) · Anesthesiology · doi:10.1097/00000542-199701000-00014 · Cited by 195
Cited by
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945
How accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661
Gil, E., Orini, M., Bailón, R., Vergara, J. M., Mainardi, L., & Laguna, P. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/015 · Cited by 461
Remote measurement of cognitive stress via heart rate variability
McDuff, D., Gontarek, S., & Picard, R. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944243 · Cited by 308
The Insula Mediates Access to Awareness of Visual Stimuli Presented Synchronously to the Heartbeat
Salomon, R., Ronchi, R., Dönz, J., Bello-Ruiz, J., Herbelin, B., Martet, R., Faivre, N., Schaller, K., & Blanke, O. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.4262-15.2016 · Cited by 178
Metadata
- Authors
- Lu, G., Yang, F., Taylor, J. A., & Stein, J. F.
- Venue
- Journal of Medical Engineering & Technology
- Publisher
- Informa UK Limited
- Published
- 2009-11
- Volume
- 33
- Issue
- 8
- Pages
- 634-641
- ISSN
- 0309-1902 (ISSN-L)
- 1464-522X
- OpenAlex
- W1995884363
- Cited by
- 324
- References
- 36
- FWCI
- 2.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparison of photoplethysmography and ECG recording to analyse heart rate variability in healthy subjects. https://app.cochat.ai/papers/10.3109/03091900903150998
- The paper
- Lu, G., Yang, F., Taylor, J. A., & Stein, J. F. (2009). A comparison of photoplethysmography and ECG recording to analyse heart rate variability in healthy subjects. Journal of Medical Engineering & Technology. https://doi.org/10.3109/03091900903150998
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.