Rapid online quantification of left ventricular volume from real-time three-dimensional echocardiographic data
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
AIMS: Determination of left ventricular (LV) volumes and ejection fraction (EF) from two-dimensional echocardiographic (2DE) images is subjective, time-consuming, and relatively inaccurate because of foreshortened views and the use of geometric assumptions. Our aims were (1) to validate a new method for rapid, online measurement of LV volumes from real-time three-dimensional echocardiographic (RT3DE) data using cardiac magnetic resonance (CMR) as the reference and (2) to compare its accuracy and reproducibility with standard 2DE measurements. METHODS AND RESULTS: CMR, 2DE, and RT3DE datasets were obtained in 50 patients. End-systolic and end-diastolic volumes (ESV and EDV) were calculated from the 2DE images using biplane method of disks. ES and ED RT3DE datasets were analysed using prototype software designed to automatically detect the endocardial surface using a deformable shell model and calculate ESV and EDV from voxel counts. 2DE and RT3DE-derived volumes were compared with CMR (linear regression, Bland-Altman analysis). In most patients, analysis of RT3DE data required <2 min per patient. RT3DE measurements correlated highly with CMR (r: 0.96, 0.97, and 0.93 for EDV, ESV, and EF, respectively) with small biases (-14 mL, -6.5 mL, -1%) and narrow limits of agreement (SD: 17 mL, 16 mL, 6.4%). 2DE measurements correlated less well with CMR (r: 0.89, 0.92, 0.86) with greater biases (-23 mL, -15 mL, 1%) and wider limits of agreement (SD: 29 mL, 24 mL, 9.5%). RT3DE resulted in lower intra-observer (EDV: 7.9 vs. 23%; ESV: 7.6 vs. 26%) and inter-observer variability (EDV: 11 vs. 26%; ESV: 13 vs. 31%). CONCLUSION: Semi-automated detection of the LV endocardial surface from RT3DE data is suitable for clinical use because it allows rapid, accurate, and reproducible measurements of LV volumes, superior to conventional 2DE methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O’Gara, P. T., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.176857 · Cited by 8,495
Moss, A. J., Zareba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,902
White, H. D., Norris, R. M., Brown, M. A., Brandt, P. W., Whitlock, R. M., & Wild, C. J. (1987) · Circulation · doi:10.1161/01.cir.76.1.44 · Cited by 2,363
ACC/AHA guidelines for coronary artery bypass graft surgery
Eagle, K. A., Guyton, R. A., Davidoff, R., Ewy, G. A., Fonger, J., Gardner, T. J., Gott, J. P., Herrmann, H. C., Marlow, R. A., Nugent, W. C., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00389-7 · Cited by 1,995
ACC/AHA guidelines for the management of patients with valvular heart disease
Bonow, R., Carabello, B., de Leon, A., Edmunds, L. H., Fedderly, B., Freed, M., Gaasch, W., McKay, C., Nishimura, R., O’Gara, P., et al. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00454-9 · Cited by 1,134
COMMITTEE MEMBERS, Eagle, K. A., Guyton, R. A., Davidoff, R., Edwards, F. H., Ewy, G. A., Gardner, T. J., Hart, J. C., Herrmann, H. C., Hillis, L. D., et al. (2004) · Circulation · doi:10.1161/01.cir.0000138790.14877.7d · Cited by 893
High-resolution transthoracic real-time three-dimensional echocardiography
Kühl, H. P., Schreckenberg, M., Rulands, D., Katoh, M., Schäfer, W., Schummers, G., Bücker, A., Hanrath, P., & Franke, A. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.01.037 · Cited by 296
Mor-Avi, V., Sugeng, L., Weinert, L., MacEneaney, P., Caiani, E. G., Koch, R., Salgo, I. S., & Lang, R. M. (2004) · Circulation · doi:10.1161/01.cir.0000142670.65971.5f · Cited by 296
Self-citationChuang, M. L., Hibberd, M. G., Salton, C. J., Beaudin, R. A., Riley, M. F., Parker, R. A., Douglas, P. S., & Manning, W. J. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00551-3 · Cited by 272
Corsi, C., Lang, R. M., Veronesi, F., Weinert, L., Caiani, E. G., MacEneaney, P., Lamberti, C., & Mor-Avi, V. (2005) · Circulation · doi:10.1161/circulationaha.104.513689 · Cited by 244
Self-citationACC/AHA 2004 Guideline Update for Coronary Artery Bypass Graft Surgery: Summary Article
Eagle, K. A., Guyton, R. A., Davidoff, R., Edwards, F. H., Ewy, G. A., Gardner, T. J., Hart, J. C., Herrmann, H. C., Hillis, L. D., Hutter, A. M., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.07.021 · Cited by 231
Gopal, A. S., King, D. L., King, D. L., Keller, A. M., & Rigling, R. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90842-o · Cited by 184
Gutiérrez‐Chico, J. L., Zamorano, J. L., de Isla, L. P., Orejas, M., Almerı́a, C., Rodrigo, J. L., Ferreirós, J., Serra, V., & Macaya, C. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.11.046 · Cited by 169
Self-citationBuck, T., Hunold, P., Wentz, K. U., Tkalec, W., Nesser, H. J., & Erbel, R. M. (1997) · Circulation · doi:10.1161/01.cir.96.12.4286 · Cited by 164
Urano, H., Ikeda, H., Ueno, T., Matsumoto, T., Murohara, T., & Imaizumi, T. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01095-0 · Cited by 164
Caiani, E. G. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2004.12.015 · Cited by 127
Real-time three-dimensional echocardiography for measurement of left ventricular volumes
Schmidt, M. A., Ohazama, C. J., Agyeman, K. O., Freidlin, R. Z., Jones, M., Laurienzo, J. M., Brenneman, C. L., Arai, A. E., von Ramm, O. T., & Panza, J. A. (1999) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00591-3 · Cited by 112
Nosir, Y. F. M., Lequin, M., Kasprzak, J., van Domburg, R. T., VLETTER, W., Yao, J., Stoker, J., ten Cate, F. J., & Roelandt, J. R. T. C. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00306-3 · Cited by 64
Lee, D., Fuisz, A., Fan, P., Hsu, T., Liu, C.-P., & Chiang, H.-T. (2001) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2001.113647 · Cited by 60
Hibberd, M. G., Chuang, M. L., Beaudin, R. A., Riley, M. F., Mooney, M. G., Fearnside, J. T., Manning, W. J., & Douglas, P. S. (2000) · American Heart Journal · doi:10.1067/mhj.2000.108513 · Cited by 57
Cited by
Plana, J. C., Galderisi, M., Barac, A., Ewer, M. S., Ky, B., Scherrer-Crosbie, M., Ganame, J., Sebag, I. A., Agler, D. A., Badano, L. P., et al. (2014) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.07.012 · Cited by 1,795
EAE/ASE Recommendations for Image Acquisition and Display Using Three-Dimensional Echocardiography
Lang, R. M., Badano, L. P., Tsang, W., Adams, D. H., Agricola, E., Buck, T., Faletra, F. F., Franke, A., Hung, J., Pérez de Isla, L., et al. (2012) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.11.010 · Cited by 1,129
Self-citationPlana, J. C., Galderisi, M., Barac, A., Ewer, M. S., Ky, B., Scherrer-Crosbie, M., Ganame, J., Sebag, I. A., Agler, D. A., Badano, L. P., et al. (2014) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeu192 · Cited by 1,058
EAE/ASE Recommendations for Image Acquisition and Display Using Three-Dimensional Echocardiography
Lang, R. M., Badano, L. P., Tsang, W., Adams, D. H., Agricola, E., Buck, T., Faletra, F. F., Franke, A., Hung, J., de Isla, L. P., et al. (2012) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jer316 · Cited by 600
Self-citationMarwick, T. H., Gillebert, T. C., Aurigemma, G., Chirinos, J., Derumeaux, G., Galderisi, M., Gottdiener, J., Haluska, B., Ofili, E., Segers, P., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2015.05.002 · Cited by 583
Self-citation
Metadata
- Authors
- Jacobs, L. D., Salgo, I. S., Goonewardena, S., Weinert, L., Coon, P., Bardo, D., Gerard, O., Allain, P., Zamorano, J. L., de Isla, L. P., Mor-Avi, V., & Lang, R. M.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-11-30
- Volume
- 27
- Issue
- 4
- Pages
- 460-468
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2136218627
- Cited by
- 335
- References
- 21
- FWCI
- 12.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.