Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 405

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Pre-procedural predictors of atrial fibrillation recurrence after circumferential pulmonary vein ablation

Berruezo, A., Tamborero, D., Mont, L., Benito, B., Tolosana, J. M., Sitges, M., Vidal, B., Arriagada, G., Mendez, F., Matiello, M., Molina, I., Brugada, J.·2007·European Heart Journal

Abstract

AIMS: The success rate of circumferential pulmonary vein ablation (CPVA) to treat atrial fibrillation (AF) ranges from 60 to 90%, depending on the series. The objective of the study was to identify predictors of AF recurrence after a standardized CPVA procedure. METHODS AND RESULTS: A series of 148 consecutive patients undergoing CPVA for symptomatic paroxysmal (60.8%), persistent (23.6%), or permanent (15.5%) AF refractory to antiarrhythmic drugs were included in the study. CPVA with the creation of supplementary block lines along the posterior wall and mitral isthmus was performed and a minimum of 6 months follow-up completed in all patients. Structural heart disease was present in 19.6% and hypertension in 33.8% of patients. After 13.1 +/- 8.4 months follow-up, 73.6% of patients were free of AF recurrences after a mean of 1.18 +/- 0.45 procedures/patient (one procedure in 85.2%, two procedures in 14.8%, and three procedures in 2.7%). Univariable analysis showed that the risk of AF recurrence increases with age (HR 1.03; 95% CI 1.00-1.06, P = 0.031), with the presence of previous hypertension (HR 2.7; 95% CI 1.43-5.07, P = 0.002), and if AF is permanent (HR 2.23; 95% CI 1.08-4.59, P = 0.042). In addition, larger anteroposterior left atrial diameter (LAD) (HR 1.11; 95% CI 1.05-1.18, P = 0.001) and larger left ventricular end-systolic diameter (HR 1.07; 95% CI 1.00-1.15, P = 0.029) prior to the procedure were associated with AF recurrence after CPVA. Cox regression analysis showed that hypertension (OR = 2.8; 95% CI 1.5-5.4; P = 0.002) and LAD (OR = 1.1; 95% CI 1.05-1.19, P < 0.001) were independent predictors of AF recurrence. The mean predicted proportion of patients with AF recurrence after CPVA of the multivariable model showed a linear relationship with the increase in LAD prior to the procedure. The presence of hypertension further increased the mean predicted proportion of patients with AF recurrence at each LAD. CONCLUSION: Hypertension and LAD are independent pre-procedural predictors of AF recurrence after CPVA to treat AF. These data may help in patient selection for AF ablation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehm027

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 405

Metadata

Authors
Berruezo, A., Tamborero, D., Mont, L., Benito, B., Tolosana, J. M., Sitges, M., Vidal, B., Arriagada, G., Mendez, F., Matiello, M., Molina, I., & Brugada, J.
Venue
European Heart Journal
Published
2007-03-23
Volume
28
Issue
7
Pages
836-841
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2137627374
Cited by
405
References
29
FWCI
13.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pre-procedural predictors of atrial fibrillation recurrence after circumferential pulmonary vein ablation. https://app.cochat.ai/papers/10.1093/eurheartj/ehm027
The paper
Berruezo, A., Tamborero, D., Mont, L., Benito, B., Tolosana, J. M., Sitges, M., Vidal, B., Arriagada, G., Mendez, F., Matiello, M., Molina, I., & Brugada, J. (2007). Pre-procedural predictors of atrial fibrillation recurrence after circumferential pulmonary vein ablation. European Heart Journal. https://doi.org/10.1093/eurheartj/ehm027

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.