The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Retinal vessel diameter and cardiovascular mortality: pooled data analysis from two older populations
Abstract
AIMS: The retinal microvasculature may reflect pre-clinical changes in the cerebral and coronary microcirculations. We assessed whether smaller retinal arterioles and larger venules predicted coronary heart disease (CHD)- and stroke-mortality. METHODS AND RESULTS: We pooled data from the Beaver Dam Eye Study (n = 4926, aged 43-86) and the Blue Mountains Eye Study (n = 3654, aged 49-97). Retinal vessel diameters were measured from digitized retinal photographs. Change point models were used to assess and document the existence of threshold effects. We defined smaller arterioles as diameters within the narrowest quintile and larger venules as diameters within the widest quintile, with other quintiles as the reference. Of 8550 participants, 7494 (88%) with complete data were included, of whom 653 died from CHD and 299 from stroke over 10-12 years follow-up. After multivariable adjustment, each standard deviation (SD) increase in arteriolar diameter, or SD decrease in venular diameter, was not found to be significantly associated with either CHD-mortality or stroke-mortality. However, smaller arterioles [hazard ratio (HR) 1.34, 95% confidence interval (CI) 1.11-1.62] and larger venules (HR 1.24, CI 1.02-1.52), predicted increased risk of CHD-mortality. These associations were mainly evident among persons aged 43-69 (smaller arterioles: HR 1.70, CI 1.27-2.28; larger venules: HR 1.41, CI 1.06-1.89). Smaller arterioles (HR 1.64, CI 1.00-2.67) and larger venules (HR 1.53, CI 0.94-2.47) were also associated with an increased risk of stroke-mortality among persons aged 43-69. CONCLUSION: Retinal vessel diameter may predict risk of CHD and stroke deaths in middle-aged persons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1990) · Choice Reviews Online · doi:10.5860/choice.27-5795 · Cited by 1,048
Revised formulas for summarizing retinal vessel diameters
Knudtson, M. D., Lee, K. E., Hubbard, L. D., Wong, T. Y., Klein, R., & Klein, B. E. K. (2003) · Current Eye Research · doi:10.1076/ceyr.27.3.143.16049 · Cited by 872
Self-citationPatton, N., Aslam, T., MacGillivray, T., Pattie, A., Deary, I. J., & Dhillon, B. (2005) · Journal of Anatomy · doi:10.1111/j.1469-7580.2005.00395.x · Cited by 807
Wong, T. Y., Klein, R., Sharrett, A. R., Duncan, B. B., Couper, D. J., Tielsch, J. M., Klein, B. E. K., & Hubbard, L. D. (2002) · JAMA · doi:10.1001/jama.287.9.1153 · Cited by 795
Self-citationWong, T. Y., Klein, R., Couper, D. J., Cooper, L. S., Shahar, E., Hubbard, L. D., Wofford, M. R., & Sharrett, A. R. (2001) · The Lancet · doi:10.1016/s0140-6736(01)06253-5 · Cited by 781
Self-citationWong, T. Y., Klein, R., Klein, B. E. K., Tielsch, J. M., Hubbard, L., & Nieto, F. J. (2001) · Survey of Ophthalmology · doi:10.1016/s0039-6257(01)00234-x · Cited by 625
Self-citationGirard, B. (2008) · Cited by 616
Egashira, K., Inou, T., Hirooka, Y., Yamada, A., Urabe, Y., & Takeshita, A. (1993) · New England Journal of Medicine · doi:10.1056/nejm199306103282302 · Cited by 559
Ikram, M. K., de Jong, F. J., Vingerling, J. R., Witteman, J. C. M., Hofman, A., Breteler, M. M. B., & de Jong, P. T. V. M. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-1390 · Cited by 501
Total cholesterol and risk of mortality in the oldest old
Weverling-Rijnsburger, A. W., Blauw, G. J., Lagaay, A. M., Knock, D. L., Meinders, A. E., & Westendorp, R. G. (1997) · The Lancet · doi:10.1016/s0140-6736(97)04430-9 · Cited by 474
Cited by
Odstrcilik, J., Kolar, R., Budai, A., Hornegger, J., Jan, J., Gazarek, J., Kubena, T., Cernosek, P., Svoboda, O., & Angelopoulou, E. (2013) · IET Image Processing · doi:10.1049/iet-ipr.2012.0455 · Cited by 472
Retinal Vascular Caliber: Systemic, Environmental, and Genetic Associations
Sun, C., Wang, J. J., Mackey, D. A., & Wong, T. Y. (2009) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2008.10.003 · Cited by 413
Self-citationMcGeechan, K., Liew, G., Macaskill, P., Irwig, L., Klein, R., Klein, B. E. K., Wang, J. J., Mitchell, P., Vingerling, J. R., de Jong, P. T. V. M., et al. (2009) · American Journal of Epidemiology · doi:10.1093/aje/kwp306 · Cited by 347
Self-citationFast Retinal Vessel Detection and Measurement Using Wavelets and Edge Location Refinement
Bankhead, P., Scholfield, C. N., McGeown, J. G., & Curtis, T. M. (2012) · PLoS ONE · doi:10.1371/journal.pone.0032435 · Cited by 337
Meta-analysis: Retinal Vessel Caliber and Risk for Coronary Heart Disease
McGeechan, K., Liew, G., Macaskill, P., Irwig, L., Klein, R., Klein, B. E. K., Wang, J. J., Mitchell, P., Vingerling, J. R., deJong, P. T. V. M., et al. (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-6-200909150-00005 · Cited by 337
Self-citation
Metadata
- Authors
- Wang, J. J., Liew, G., Klein, R., Rochtchina, E., Knudtson, M. D., Klein, B. E. K., Wong, T. Y., Burlutsky, G., & Mitchell, P.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-07-10
- Volume
- 28
- Issue
- 16
- Pages
- 1984-1992
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2149144582
- Cited by
- 330
- References
- 51
- FWCI
- 9.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Retinal vessel diameter and cardiovascular mortality: pooled data analysis from two older populations. https://app.cochat.ai/papers/10.1093/eurheartj/ehm221
- The paper
- Wang, J. J., Liew, G., Klein, R., Rochtchina, E., Knudtson, M. D., Klein, B. E. K., Wong, T. Y., Burlutsky, G., & Mitchell, P. (2007). Retinal vessel diameter and cardiovascular mortality: pooled data analysis from two older populations. European Heart Journal. https://doi.org/10.1093/eurheartj/ehm221
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.