64-multislice detector computed tomography coronary angiography as potential alternative to conventional coronary angiography: a systematic review and meta-analysis
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
AIMS: To evaluate the diagnostic accuracy of 64-slice multi-detector computed tomography coronary angiography (64-SCTA) compared with the standard reference conventional coronary angiography (CCA). METHODS AND RESULTS: Based on a systematic search, 27 studies including 1740 patients were eligible for meta-analyses. Nineteen studies examined native coronary arteries (n = 1,251), four studies examined coronary artery by-pass grafts (CABG) (n = 271), and five studies examined coronary stents (n = 270). Overall 18 920 segments were assessable and 810 (4%) were unassessable. The prevalence of native coronary artery stenosis in per-segment (19 studies) and per-patients (13 studies) populations were 19 and 57.5% respectively. Accuracy tests with 95% confidence intervals comparing 64-SCTA vs. CCA showed that sensitivity, specificity, positive predictive and negative predictive values for native coronary arteries were 86(85-87), 96(95.5-96.5), 83, and 96.5% by per-segment analysis; 97.5(96-99), 91(87.5-94), 93, and 96.5% by per-patient analysis; 98.5(96-99.5), 96(93.5-97.5), 92 and 99% for CABGs; 80(70-88.5), 95(92-97), 80, and 95% for stent restenosis; and 87(86.5-88), 96(95.5-96.5), 83.5, and 97% by overall per-segment analysis. CONCLUSION: The high diagnostic accuracy of 64-SCTA validates this non-invasive technique as a potential alternative to CCA in carefully selected populations suspected for coronary stenosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of probability as an aid in the clinical diagnosis of coronary artery disease.
Diamond, G. A., & Forrester, J. S. (1979) · New England Journal of Medicine · doi:10.1056/nejm197906143002402 · Cited by 2,664
Meta-DiSc: a software for meta-analysis of test accuracy data
Zamora, J., Abraira, V., Muriel, A., Khan, K., & Coomarasamy, A. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-31 · Cited by 1,883
Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries
de González, A. B., & Darby, S. (2004) · The Lancet · doi:10.1016/s0140-6736(04)15433-0 · Cited by 1,718
Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography
Raff, G. L., Gallagher, M. J., O’Neill, W. W., & Goldstein, J. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.056 · Cited by 1,472
Einstein, A. J., Henzlova, M. J., & Rajagopalan, S. (2007) · JAMA · doi:10.1001/jama.298.3.317 · Cited by 1,410
Budoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Systematic reviews of evaluations of diagnostic and screening tests
Deeks, J. J. (2001) · BMJ · doi:10.1136/bmj.323.7305.157 · Cited by 1,340
Quantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed Tomography
Leber, A. W., Knez, A., von Ziegler, F., Becker, A., Nikolaou, K., Paul, S., Wintersperger, B., Reiser, M., Becker, C. R., Steinbeck, G., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.071 · Cited by 1,109
Mollet, N. R., Cademartiri, F., van Mieghem, C. A. G., Runza, G., McFadden, E. P., Baks, T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2005) · Circulation · doi:10.1161/circulationaha.105.533471 · Cited by 1,018
Accuracy of MSCT coronary angiography with 64-slice technology: first experience
Leschka, S., Alkadhi, H., Plass, A., Desbiolles, L., Grünenfelder, J., Marincek, B., & Wildermuth, S. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi261 · Cited by 960
Conducting systematic reviews of diagnostic studies: didactic guidelines
Devillé, W. L., Buntinx, F., Bouter, L. M., Montori, V. M., de Vet, H. C., van der Windt, D. A., & Bezemer, P. D. (2002) · BMC Medical Research Methodology · doi:10.1186/1471-2288-2-9 · Cited by 960
Hausleiter, J., Meyer, T., Hadamitzky, M., Huber, E., Zankl, M., Martinoff, S., Kastrati, A., & Schömig, A. (2006) · Circulation · doi:10.1161/circulationaha.105.602490 · Cited by 705
Schuijf, J. D., Wijns, W., Jukema, J. W., Atsma, D. E., de Roos, A., Lamb, H. J., Stokkel, M. P. M., Dibbets-Schneider, P., Decramer, I., De Bondt, P., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.05.080 · Cited by 479
Hamon, M., Biondi-Zoccai, G. G. L., Malagutti, P., Agostoni, P., Morello, R., Valgimigli, M., & Hamon, M. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.08.028 · Cited by 460
Achenbach, S., Ropers, D., Hoffmann, U., MacNeill, B., Baum, U., Pohle, K., Brady, T. J., Pomerantsev, E., Ludwig, J., Flachskampf, F. A., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.09.053 · Cited by 408
No role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Patient-Specific Dose and Radiation Risk Estimation in Pediatric Cardiac Catheterization
Bacher, K., Bogaert, E., Lapere, R., De Wolf, D., & Thierens, H. (2005) · Circulation · doi:10.1161/01.cir.0000151098.52656.3a · Cited by 274
Coles, D. R., Smail, M. A., Negus, I. S., Wilde, P., Oberhoff, M., Karsch, K. R., & Baumbach, A. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.078 · Cited by 265
Gallagher, M. J., Ross, M. A., Raff, G. L., Goldstein, J. A., O’Neill, W. W., & O’Neil, B. J. (2006) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2006.06.043 · Cited by 262
Schuijf, J. D., Bax, J. J., Shaw, L. J., de Roos, A., Lamb, H. J., van der Wall, E. E., & Wijns, W. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.03.022 · Cited by 255
Ropers, D., Pohle, F.-K., Kuettner, A., Pflederer, T., Anders, K., Daniel, W. G., Bautz, W., Baum, U., & Achenbach, S. (2006) · Circulation · doi:10.1161/circulationaha.106.631051 · Cited by 253
Meijboom, W. B., Mollet, N. R., Van Mieghem, C. A. G., Kluin, J., Weustink, A. C., Pugliese, F., Vourvouri, E., Cademartiri, F., Bogers, A. J. J. C., Krestin, G. P., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.06.054 · Cited by 249
Schuijf, J. D., Pundziute, G., Jukema, J. W., Lamb, H. J., van der Hoeven, B. L., de Roos, A., van der Wall, E. E., & Bax, J. J. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.01.092 · Cited by 232
(2007) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2007.05.034 · Cited by 185
Schoepf, U. J., Zwerner, P. L., Savino, G., Herzog, C., Kerl, J. M., & Costello, P. (2007) · Radiology · doi:10.1148/radiol.2441052145 · Cited by 180
van Mieghem, C. A. G., Cademartiri, F., Mollet, N. R., Malagutti, P., Valgimigli, M., Meijboom, W. B., Pugliese, F., McFadden, E. P., Ligthart, J. M. R., Runza, G., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.608950 · Cited by 168
Multidetector Computed Tomography for the Diagnosis of Coronary Artery Disease: A Systematic Review
Stein, P. D., Beemath, A., Kayali, F., Skaf, E., Sánchez, J., & Olson, R. E. (2006) · The American Journal of Medicine · doi:10.1016/j.amjmed.2005.06.071 · Cited by 164
Sun, Z., & Jiang, W. J. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2006.06.009 · Cited by 138
Ghostine, S., Caussin, C., Daoud, B., Habis, M., Perrier, E., Pesenti-Rossi, D., Sigal-Cinqualbre, A. B., Angel, C.-Y., Lancelin, B., Capderou, A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.04.103 · Cited by 127
Dewey, M., & Hamm, B. (2006) · European Radiology · doi:10.1007/s00330-006-0439-3 · Cited by 123
64-Slice CT coronary angiography in patients with non-ST elevation acute coronary syndrome
Meijboom, W. B., Mollet, N. R., van Mieghem, C. A. G., Weustink, A. C., Pugliese, F., van Pelt, N., Cademartiri, F., Vourvouri, E. C., de Jaegere, P. P. T., Krestin, G. P., et al. (2007) · Heart · doi:10.1136/hrt.2006.112771 · Cited by 118
Economic and biological costs of cardiac imaging
Picano, E. (2005) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-3-13 · Cited by 96
Rubinshtein, R., Halon, D. A., Gaspar, T., Schliamser, J. E., Yaniv, N., Ammar, R., Flugelman, M. Y., Peled, N., & Lewis, B. S. (2007) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.10.059 · Cited by 50
Multi-slice computed tomography in coronary artery disease
JONES, C., Athanasiou, T., Dunne, N., KIRBY, J., Attaran, S., Chow, A., Purkayastha, S., & Darzi, A. W. (2006) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2006.06.004 · Cited by 26
van der Zaag–Loonen, H. J., Dikkers, R., de Bock, G. H., & Oudkerk, M. (2006) · European Radiology · doi:10.1007/s00330-006-0312-4 · Cited by 23
Cited by
Budoff, M. J., Dowe, D., Jollis, J. G., Gitter, M., Sutherland, J., Halamert, E., Scherer, M., Bellinger, R., Martin, A., Benton, R., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.031 · Cited by 2,125
Danad, I., Raijmakers, P. G., Driessen, R. S., Leipsic, J., Raju, R., Naoum, C., Knuuti, J., Mäki, M., Underwood, R. S., Min, J. K., et al. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2017.2471 · Cited by 475
Bluemke, D. A., Achenbach, S., Budoff, M., Gerber, T. C., Gersh, B., Hillis, L. D., Hundley, W. G., Manning, W. J., Printz, B. F., Stuber, M., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.189695 · Cited by 461
ICRP Publication 120: Radiological Protection in Cardiology
Cousins, C., Miller, D. L., Bernardi, G., Rehani, M. M., Schofield, P., Vañó, E., Einstein, A. J., Geiger, B., Heintz, P., Padovani, R., et al. (2013) · Annals of the ICRP · doi:10.1016/j.icrp.2012.09.001 · Cited by 428
Kajander, S., Joutsiniemi, E., Saraste, M., Pietilä, M., Ukkonen, H., Saraste, A., Sipilä, H. T., Teräs, M., Mäki, M., Airaksinen, J., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.915009 · Cited by 402
Metadata
- Authors
- Abdulla, J., Abildstrom, S. Z., Gotzsche, O., Christensen, E., Kober, L., & Torp-Pedersen, C.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-11-05
- Volume
- 28
- Issue
- 24
- Pages
- 3042-3050
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2157577400
- Cited by
- 357
- References
- 35
- FWCI
- 3.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.