The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy
Open accessAbstract
AIMS: To prospectively investigate the diagnostic accuracy of dual-source computed tomography coronary angiography (CTCA) to diagnose coronary stenoses in relation to body mass index (BMI), Agatston score (AS), and heart rate (HR) as compared with catheter coronary angiography (CCA). METHODS AND RESULTS: Hundred and fifty consecutive patients (47 female, mean age 62.9 +/- 12.1 years) underwent dual-source CTCA without HR control. Patients were divided into subgroups depending on the median of their BMI (26.0 kg/m2), AS (194), and HR (66 b.p.m.). CCA was considered the standard of reference. Mean BMI was 26.5 +/- 4.2 kg/m2 (range 18.3-39.1 kg/m2), mean AS was 309 +/- 408 (range 0-4387), and HR was 68.5 +/- 12.6 b.p.m. (range 35-102 b.p.m.). Diagnostic image quality was found in 98.1% of all segments (2020/2059). Considering not-evaluative segments at CTCA as false-positive, overall per-patient sensitivity, specificity, positive, and negative predictive value were 96.6%, 86.8%, 82.6%, and 97.5%, respectively. High HR did not deteriorate diagnostic accuracy of CTCA. High BMI and AS were associated with a decrease in per-patient specificity to 84.1% and 77.8%, respectively, while sensitivity and negative predictive value remained high. CONCLUSION: Dual-source CTCA provides high diagnostic accuracy irrespective of the HR and serves as a modality to rule-out coronary artery stenoses even in patients with high BMI and AS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786
Cited by
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
Self-citationState of the Art: Iterative CT Reconstruction Techniques
Geyer, L. L., Schoepf, U. J., Meinel, F. G., Nance, J. W., Bastarrika, G., Leipsic, J. A., Paul, N. S., Rengo, M., Laghi, A., & De Cecco, C. N. (2015) · Radiology · doi:10.1148/radiol.2015132766 · Cited by 704
Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance
Scheffel, H., Alkadhi, H., Leschka, S., Plass, A., Desbiolles, L., Guber, I., Krauss, T., Gruenenfelder, J., Genoni, M., Luescher, T. F., et al. (2008) · Heart · doi:10.1136/hrt.2008.149971 · Cited by 291
Self-citationSchuetz, G. M., Zacharopoulou, N. M., Schlattmann, P., & Dewey, M. (2010) · Annals of Internal Medicine · doi:10.7326/0003-4819-152-3-201002020-00008 · Cited by 265
High-pitch spiral acquisition: A new scan mode for coronary CT angiography
Achenbach, S., Marwan, M., Schepis, T., Pflederer, T., Bruder, H., Allmendinger, T., Petersilka, M., Anders, K., Lell, M., Kuettner, A., et al. (2009) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2009.02.008 · Cited by 258
Metadata
- Authors
- Alkadhi, H., Scheffel, H., Desbiolles, L., Gaemperli, O., Stolzmann, P., Plass, A., Goerres, G. W., Luescher, T. F., Genoni, M., Marincek, B., Kaufmann, P. A., & Leschka, S.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-02-07
- Volume
- 29
- Issue
- 6
- Pages
- 766-776
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2108717648
- Cited by
- 182
- References
- 1
- FWCI
- 20.55
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy. https://app.cochat.ai/papers/10.1093/eurheartj/ehn044
- The paper
- Alkadhi, H., Scheffel, H., Desbiolles, L., Gaemperli, O., Stolzmann, P., Plass, A., Goerres, G. W., Luescher, T. F., Genoni, M., Marincek, B., Kaufmann, P. A., & Leschka, S. (2008). Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy. European Heart Journal. https://doi.org/10.1093/eurheartj/ehn044
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.