Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 189

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Strain rate imaging for functional quantification of the left atrium: atrial deformation predicts the maintenance of sinus rhythm after catheter ablation of atrial fibrillation

Open access
Schneider, C., Malisius, R., Krause, K., Lampe, F., Bahlmann, E., Boczor, S., Antz, M., Ernst, S., Kuck, K.-H. · 2008 · European Heart Journal

Abstract

AIMS: The aim of the study was to investigate the atrial myocardial deformation properties using ultrasound strain rate (SR) imaging in patients after catheter ablation of atrial fibrillation (AF) and to compare its prognostic value in maintaining sinus rhythm. METHODS AND RESULTS: A total of 118 patients with AF (74 paroxysmal AF, 44 persistent AF) underwent transthoracic echocardiography with Doppler-derived SR examinations before and after ablation as well as during 3 months of follow-up (FU). Peak SR and strain (S) were measured at each left atrium (LA) segment (septal, lateral, anterior, inferior) during systole (LAs) and at early (LAe) and late diastole (LAa). Clinical and echocardiographic parameters of patients with maintained sinus rhythm during FU were compared with those with recurrent AF and controls (n = 25 patients). Of 118 patients 82 (69%) showed stable sinus rhythm during FU. Atrial myocardial properties after catheter ablation differed significantly in patients with paroxysmal AF (SR-LAs 2.5 s(-1), S-LAs 30%, SR-LAa -2.2 s(-1)) from patients with persistent AF (SR-LAs 2.3 s(-1), S-LAs 25%, SR-LAa -1.9 s(-1)) and controls (SR-LAs 4.1 s(-1), S-LAs 88%, SR-LAa -2.9 s(-1)) (P = 0.011). Best individual predictors of sinus rhythm maintenance were cut-off values of >2.25 s(-1) for septal and inferior SR-LAs and of >19.5% for inferior S-LAs (P < 0.001). LA deformation properties increased in patients with maintained sinus rhythm during FU in contrast to patients with recurrent AF (P = 0.001). CONCLUSION: SR imaging enables the quantitative assessment of the LA function and can be considered as a potential marker of atrial reverse remodelling. Patients with higher atrial S and SR after catheter ablation appear to have a greater likelihood of maintenance of sinus rhythm. This may have further implications for the anticoagulation regime and the risk of cardioembolic complications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehn168

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 189

Metadata

Authors
Schneider, C., Malisius, R., Krause, K., Lampe, F., Bahlmann, E., Boczor, S., Antz, M., Ernst, S., & Kuck, K.-H.
Venue
European Heart Journal
Published
2008-01-18
Volume
29
Issue
11
Pages
1397-1409
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2164376203
Cited by
189
References
6
FWCI
7.70
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Strain rate imaging for functional quantification of the left atrium: atrial deformation predicts the maintenance of sinus rhythm after catheter ablation of atrial fibrillation. https://app.cochat.ai/papers/10.1093/eurheartj/ehn168
The paper
Schneider, C., Malisius, R., Krause, K., Lampe, F., Bahlmann, E., Boczor, S., Antz, M., Ernst, S., & Kuck, K.-H. (2008). Strain rate imaging for functional quantification of the left atrium: atrial deformation predicts the maintenance of sinus rhythm after catheter ablation of atrial fibrillation. European Heart Journal. https://doi.org/10.1093/eurheartj/ehn168

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.