Stress Echocardiography Expert Consensus Statement--Executive Summary: European Association of Echocardiography (EAE) (a registered branch of the ESC)
Open accessThe DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
Abstract
Stress echocardiography is the combination of echocardiography with a physical, pharmacological, or electrical stress. The diagnostic endpoint for the detection of myocardial ischaemia is the induction of a transient worsening in regional function during stress. Stress echocardiography provides similar diagnostic and prognostic accuracy to radionuclide stress perfusion imaging, but at a substantially lower cost, without environmental impact, and with no biohazards for the patient and the physician. Among different stresses of comparable diagnostic and prognostic accuracy, semisupine exercise is the most used, dobutamine the best test for viability, and dipyridamole the safest and simplest pharmacological stress and the most suitable for combined wall motion coronary flow reserve assessment. The additional clinical benefit of myocardial perfusion contrast echocardiography and myocardial velocity imaging has been inconsistent to date, whereas the possibility of performing coronary flow reserve evaluation of the left anterior descending coronary artery by transthoracic Doppler echocardiography adds another potentially important dimension to stress echocardiography. New emerging fields of application taking advantage of the versatility of the technique are Doppler stress echo in valvular heart disease and in dilated cardiomyopathy. In spite of its dependence on the operator's training, stress echocardiography is today the best (most cost-effective and risk-effective) possible imaging choice to achieve the still elusive target of sustainable cardiac imaging in the field of non-invasive diagnosis of coronary artery disease. In 1935, Tennant and Wiggers 1 demonstrated that coronary occlusion immediately resulted in instantaneous abnormality of wall motion. A large body of evidence 2–5 recognized for the first time that transient dys-synergy was an early, sensitive, specific marker of transient ischaemia, clearly more accurate than ECG changes and pain. In European clinical practice, 6–10 stress echo has been embedded in the legal and cultural framework of existing European laws and medical imaging referral guidelines. The radiation used for medical examinations and tests is the greatest man-made source of radiation exposure. 11 Small individual risks of each test performed with ionizing radiation multiplied by a billion examinations become significant population risks. For this reason, in Europe, both the law 11 and the referral guidelines for medical imaging 12 recommend a justified, optimized, and responsible use of testing with ionizing radiation. European Commission referral guidelines were released in 2001 in application of the Euratom Directive, and explicitly state that a non-ionizing technique must be used whenever it will give information grossly comparable with an ionizing investigation. For instance, ‘because MRI does not use ionizing radiation, MRI should be preferred when both CT and MRI would provide similar information and when both are available’. 12 In this perspective of the medical, as well as socio-economic and biological impact of medical imaging, it is imperative to increase all efforts to improve appropriateness 13 and minimize the radiation burden of stress imaging for the population and the individual patient. 14 The imperative of sustainability of medical imaging is likely to become increasingly important in the near future, also from a US perspective. 15 , 16 In the quest for sustainability, stress echocardiography has unsurpassed assets of low cost, absence of environmental impact, and lack of biological effects for both the patient 17 and the operator compared with equally accurate, but less sustainable, competing techniques. 18 Stress echocardiography is the combination of 2D echocardiography with a physical, pharmacological, or electrical stress. 19 The diagnostic endpoint for the detection of myocardial ischaemia is the induction of a transient change in regional function during stress. The stress echo sign of ischaemia is a stress-induced worsening of function in a region contracting normally at baseline. The stress echo sign of myocardial viability is a stress-induced improvement of function during low levels of stress in a region that is abnormal at rest. A transient regional imbalance between oxygen demand and supply usually results in myocardial ischaemia, the signs and symptoms of which can be used as a diagnostic tool. Myocardial ischaemia results in a typical ‘cascade’ of events in which the various markers are hierarchically ranked in a well-defined time sequence. 20 Flow heterogeneity, especially between the subendocardial and subepicardial perfusion, is the forerunner of ischaemia, followed by metabolic changes, alteration in regional mechanical function, and only at a later stage by electrocardiographic changes, global left ventricular (LV) dysfunction, and pain. The pathophysiological concept of the ischaemic cascade is translated clinically into a gradient of sensitivi
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, R. J., Wu, E., Rafael, A., Chen, E.-L., Parker, M. A., Simonetti, O., Klocke, F. J., Bonow, R. O., & Judd, R. M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200011163432003 · Cited by 3,306
Gibbons, R. J., Abrams, J., Chatterjee, K., Daley, J., Deedwania, P. C., Douglas, J. S., Ferguson, T. B., Fihn, S. D., Fraker, T. D., Gardin, J. M., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02848-6 · Cited by 1,689
Allman, K. C., Shaw, L. J., Hachamovitch, R., & Udelson, J. E. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01726-6 · Cited by 1,422
Authors/Task Force Members (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl001 · Cited by 1,336
THE EFFECT OF CORONARY OCCLUSION ON MYOCARDIAL CONTRACTION
Tennant, R., & Wiggers, C. J. (1935) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1935.112.2.351 · Cited by 1,128
Coronary Magnetic Resonance Angiography for the Detection of Coronary Stenoses
Kim, W. Y., Danias, P. G., Stuber, M., Flamm, S. D., Plein, S., Nagel, E., Langerak, S. E., Weber, O. M., Pedersen, E. M., Schmidt, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010866 · Cited by 903
American College of Radiology White Paper on Radiation Dose in Medicine
Amis, E. S., Butler, P. F., Applegate, K. E., Birnbaum, S. B., Brateman, L. F., Hevezi, J. M., Mettler, F. A., Morin, R. L., Pentecost, M. J., Smith, G. G., et al. (2007) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2007.03.002 · Cited by 902
Nagel, E., Lehmkuhl, H. B., Bocksch, W., Klein, C., Vogel, U., Frantz, E., Ellmer, A., Dreysse, S., & Fleck, E. (1999) · Circulation · doi:10.1161/01.cir.99.6.763 · Cited by 792
Committee Members, Gibbons, R. J., Abrams, J., Chatterjee, K., Daley, J., Deedwania, P. C., Douglas, J. S., Ferguson, T. B., Fihn, S. D., Fraker, T. D., et al. (2003) · Circulation · doi:10.1161/01.cir.0000047041.66447.29 · Cited by 567
Methodology, Feasibility, Safety and Diagnostic Accuracy of Dobutamine Stress Echocardiography
Geleijnse, M. L., Fioretti, P. M., & Roelandt, J. R. T. C. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00206-4 · Cited by 485
Cited by
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab670 · Cited by 19,442
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,655
2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab368 · Cited by 13,344
Self-citation2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw128 · Cited by 11,429
Self-citationRoffi, M., Patrono, C., Collet, J.-P., Mueller, C., Valgimigli, M., Andreotti, F., Bax, J. J., Borger, M. A., Brotons, C., Chew, D. P., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv320 · Cited by 8,261
Self-citation2016 ESC Guidelines for the Diagnosis and Treatment of Acute and Chronic Heart Failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · European Journal of Heart Failure · doi:10.1002/ejhf.592 · Cited by 5,866
Self-citationMancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
Collet, J.-P., Thiele, H., Barbato, E., Barthélémy, O., Bauersachs, J., Bhatt, D. L., Dendale, P., Dorobantu, M., Edvardsen, T., Folliguet, T., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa575 · Cited by 5,037
2024 ESC Guidelines for the management of chronic coronary syndromes
Vrints, C., Andreotti, F., Koskinas, K. C., Rossello, X., Adamo, M., Ainslie, J., Banning, A. P., Budaj, A., Buechel, R. R., Chiariello, G. A., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae177 · Cited by 2,774
Authors/Task Force Members:, McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., et al. (2022) · European Journal of Heart Failure · doi:10.1002/ejhf.2333 · Cited by 2,171
(2014) · European Heart Journal · doi:10.1093/eurheartj/ehu282 · Cited by 1,656
Gulati, M., Levy, P. D., Mukherjee, D., Amsterdam, E., Bhatt, D. L., Birtcher, K. K., Blankstein, R., Boyd, J., Bullock-Palmer, R. P., Conejo, T., et al. (2021) · Circulation · doi:10.1161/cir.0000000000001029 · Cited by 1,611
2021 AHA/ACC/ASE/CHEST/SAEM/SCCT/SCMR Guideline for the Evaluation and Diagnosis of Chest Pain
Gulati, M., Levy, P. D., Mukherjee, D., Amsterdam, E., Bhatt, D. L., Birtcher, K. K., Blankstein, R., Boyd, J., Bullock-Palmer, R. P., Conejo, T., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.07.053 · Cited by 824
Mancia, G., Fagard, R., Narkiewicz, K., Redon, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2014) · Blood Pressure · doi:10.3109/08037051.2014.868629 · Cited by 739
Authors/Task Force Members, Poldermans, D., Bax, J. J., Boersma, E., De Hert, S., Eeckhout, E., Fowkes, G., Gorenek, B., Hennerici, M. G., Iung, B., et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp337 · Cited by 738
Self-citationDaskalopoulou, S. S., Rabi, D. M., Zarnke, K. B., Dasgupta, K., Nerenberg, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., Bolli, P., et al. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.02.016 · Cited by 684
Poldermans, D., Bax, J. J., Boersma, E., De Hert, S., Eeckhout, E., Fowkes, G., Gorenek, B., Hennerici, M. G., Iung, B., Kelm, M., et al. (2010) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e328334c017 · Cited by 683
Self-citationRoffi, M., Patrono, C., Collet, J.-P., Mueller, C., Valgimigli, M., Andreotti, F., Bax, J. J., Borger, M. A., Brotons, C., Chew, D. P., et al. (2015) · Kardiologia Polska · doi:10.5603/kp.2015.0243 · Cited by 458
Self-citationJaarsma, C., Leiner, T., Bekkers, S. C., Crijns, H. J., Wildberger, J. E., Nagel, E., Nelemans, P. J., & Schalla, S. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.12.040 · Cited by 456
2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · Kardiologia Polska · doi:10.5603/kp.2016.0141 · Cited by 444
Self-citationLancellotti, P., Pellikka, P. A., Budts, W., Chaudhry, F. A., Donal, E., Dulgheru, R., Edvardsen, T., Garbi, M., Ha, J.-W., Kane, G. C., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jew190 · Cited by 438
Self-citationGulati, M., Levy, P. D., Mukherjee, D., Amsterdam, E., Bhatt, D. L., Birtcher, K. K., Blankstein, R., Boyd, J., Bullock-Palmer, R. P., Conejo, T., et al. (2021) · Circulation · doi:10.1161/cir.0000000000001030 · Cited by 428
Mancia, G., Fagard, R., Narkiewicz, K., Redon, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Blood Pressure · doi:10.3109/08037051.2013.812549 · Cited by 426
2014 ESC/ESA Guidelines on non-cardiac surgery: cardiovascular assessment and management
Kristensen, S. D., Knuuti, J., Saraste, A., Anker, S., Bøtker, H. E., De Hert, S., Ford, I., Juanatey, J. R. G., Gorenek, B., Heyndrickx, G. R., et al. (2014) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000150 · Cited by 408
Characterization of the rdar morphotype, a multicellular behaviour in Enterobacteriaceae
Römling, U. (2005) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-005-4557-x · Cited by 338
Chew, D. P., Scott, I. A., Cullen, L., French, J. K., Briffa, T. G., Tideman, P. A., Woodruffe, S., Kerr, A., Branagan, M., & Aylward, P. E. G. (2016) · Heart, Lung and Circulation · doi:10.1016/j.hlc.2016.06.789 · Cited by 314
Lancellotti, P., Pellikka, P. A., Budts, W., Chaudhry, F. A., Donal, E., Dulgheru, R., Edvardsen, T., Garbi, M., Ha, J. W., Kane, G. C., et al. (2017) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2016.10.016 · Cited by 310
Self-citationCardim, N., Galderisi, M., Edvardsen, T., Plein, S., Popescu, B. A., D'Andrea, A., Bruder, O., Cosyns, B., Davin, L., Donal, E., et al. (2015) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jeu291 · Cited by 284
Self-citationStankovic, I., Prinz, C., Ciarka, A., Daraban, A. M., Kotrc, M., Aarones, M., Szulik, M., Winter, S., Belmans, A., Neskovic, A. N., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jev288 · Cited by 215
“stress echocardiography), even the guideline-recommended method for decision-making.(32) Nevertheless, clinical utility of ApRock and SF could potentially be limited by interobserver disagreement, which is most often observed in patients with borderline dyssynchrony.”
MethodSelf-citationPanza, J. A., Holly, T. A., Asch, F. M., She, L., Pellikka, P. A., Velazquez, E. J., Lee, K. L., Borges-Neto, S., Farsky, P. S., Jones, R. H., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.02.014 · Cited by 199
Galderisi, M., Henein, M. Y., D'hooge, J., Sicari, R., Badano, L. P., Zamorano, J. L., Roelandt, J. R. T. C., & on behalf of the European Association of Echocardiography (2011) · European Journal of Echocardiography · doi:10.1093/ejechocard/jer051 · Cited by 164
Self-citationIngram, T. E., Fraser, A. G., Bleasdale, R. A., Ellins, E. A., Margulescu, A. D., Halcox, J. P., & James, P. E. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.03.050 · Cited by 69
Coronary microvascular dysfunction
Sucato, V., Novo, G., Saladino, A., Evola, S., & Galassi, A. R. (2020) · Minerva Cardioangiologica · doi:10.23736/s0026-4725.20.05070-7 · Cited by 30
Metadata
- Authors
- Sicari, R., Nihoyannopoulos, P., Evangelista, A., Kasprzak, J., Lancellotti, P., Poldermans, D., Voigt, J.-U., Zamorano, J. L., & on behalf of the European Association of Echocardiography
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-09-10
- Volume
- 30
- Issue
- 3
- Pages
- 278-289
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2179377441
- Cited by
- 357
- References
- 70
- FWCI
- 9.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.