Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 315

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Substrate and Trigger Ablation for Reduction of Atrial Fibrillation (STAR AF): a randomized, multicentre, international trial

Open access
Verma, A., Mantovan, R., Macle, L., De Martino, G., Chen, J., Morillo, C. A., Novak, P., Calzolari, V., Guerra, P. G., Nair, G., Torrecilla, E. G., Khaykin, Y. · 2010 · European Heart Journal

Abstract

AIMS: This multicentre, randomized trial compared three strategies of AF ablation: ablation of complex fractionated electrograms (CFE) alone, pulmonary vein isolation (PVI) alone, and combined PVI + CFE ablation, using standardized automated mapping software. METHODS AND RESULTS: Patients with drug-refractory, high-burden paroxysmal (episodes >6 h, >4 in 6 months) or persistent atrial fibrillation (AF) were enrolled at eight centres. Patients (n = 100) were randomized to one of three arms. For CFE alone (n = 34), spontaneous/induced AF was mapped using validated, automated CFE software and all sites <120 ms were ablated until AF termination/non-inducibility. For PVI (n = 32), all four PV antra were isolated and confirmed using a circular catheter. For PVI + CFE (n = 34), all four PV antra were isolated, followed by AF induction and ablation of all CFE sites until AF termination/non-inducibility. Patients were followed at 3, 6, and 12 months with a visit, ECG, 48 h Holter. Atrial fibrillation symptoms were confirmed by loop recording. Repeat procedures were allowed within the first 6 months. The primary endpoint was freedom from AF >30 s at 1 year. Patients (age 57 +/- 10 years, LA size 42 +/- 6 mm) were 35% persistent AF. In CFE, ablation terminated AF in 68%. Only 0.4 PVs per patient were isolated as a result of CFE. In PVI, 94% had all four PVs successfully isolated. In PVI + CFE, 94% had all four PVs isolated, 76% had inducible AF with additional CFE ablation, with 73% termination of AF. There were significantly more repeat procedures in the CFE arm (47%) vs. PVI (31%) or PVI + CFE (15%) (P = 0.01). After one procedure, PVI + CFE had a significantly higher freedom from AF (74%) compared with PVI (48%) and CFE (29%) (P = 0.004). After two procedures, PVI + CFE still had the highest success (88%) compared with PVI (68%) and CFE (38%) (P = 0.001). Ninety-six percent of these patients were off anti-arrhythmics. Complications were two tamponades, no PV stenosis, and no mortality. CONCLUSION: In high-burden paroxysmal/persistent AF, PVI + CFE has the highest freedom from AF vs. PVI or CFE alone after one or two procedures. Complex fractionated electrogram alone has the lowest one and two procedure success rates with a higher incidence of repeat procedures. ClinicalTrials.gov identifier number NCT00367757.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehq041

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 315

Metadata

Authors
Verma, A., Mantovan, R., Macle, L., De Martino, G., Chen, J., Morillo, C. A., Novak, P., Calzolari, V., Guerra, P. G., Nair, G., Torrecilla, E. G., & Khaykin, Y.
Venue
European Heart Journal
Published
2010-03-09
Volume
31
Issue
11
Pages
1344-1356
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2105496456
Cited by
315
References
25
FWCI
19.42
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Substrate and Trigger Ablation for Reduction of Atrial Fibrillation (STAR AF): a randomized, multicentre, international trial. https://app.cochat.ai/papers/10.1093/eurheartj/ehq041
The paper
Verma, A., Mantovan, R., Macle, L., De Martino, G., Chen, J., Morillo, C. A., Novak, P., Calzolari, V., Guerra, P. G., Nair, G., Torrecilla, E. G., & Khaykin, Y. (2010). Substrate and Trigger Ablation for Reduction of Atrial Fibrillation (STAR AF): a randomized, multicentre, international trial. European Heart Journal. https://doi.org/10.1093/eurheartj/ehq041

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.