Transcatheter aortic valve implantation: 3-year outcomes of self-expanding CoreValve prosthesis
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
AIMS: The paucity of evidences about the long-term durability of currently available transcatheter prostheses is one of the main issues of transcatheter aortic valve implantation (TAVI). We sought to assess 3-year clinical and echocardiographic outcomes of patients undergoing TAVI with the third generation CoreValve prosthesis (Medtronic Incorporation, MN, USA). METHODS AND RESULTS: From the Italian CoreValve registry, 181 who underwent TAVI from June 2007 to August 2008 and eligible for 3-year follow-up were analysed. All outcomes were defined according to the Valve Academic Research Consortium. All-cause mortality at 1, 2, and 3 years was 23.6, 30.3, and 34.8%, respectively. Cardiovascular death at 1, 2, and 3 years was 11.2, 12.1, and 13.5%, respectively. The actuarial survival free from a composite of death, major stroke, myocardial infarction, and life-threatening bleeding was 69.6% at 1 year, 63.5% at 2 years, and 59.7% at 3 years. Patients with renal insufficiency had a higher mortality at 3-year follow-up (49.0 vs. 29.2%, P = 0.007); moreover, patients experiencing post-procedural major or life-threatening bleeding had a higher rate of mortality already seen at 30 days (21.6 vs. 2.8%; P < 0.001) and this result was sustained at 3-year follow-up (62.2 vs. 27.7%; P < 0.001). Mean pressure gradients decreased from 52.2 ± 18.1 mmHg (pre-TAVI) to 10.3 ± 3.1 mmHg (1-year post-TAVI) (P < 0.001); aortic valve area increased from 0.6 ± 0.2 cm(2) (pre-TAVI) to 1.8 ± 0.4 cm(2) (1-year post-TAVI); these results remained stable over the 3 years of follow-up. Paravalvular leak was observed in the majority of patients. There were no cases of progression to moderate or severe regurgitation. No cases of structural valve deterioration were observed. CONCLUSION: This multicentre study demonstrates that TAVI with the 18-Fr CoreValve ReValving System is associated with sustained clinical and functional cardiovascular benefits in high-risk patients with symptomatic aortic stenosis up to 3-year follow-up. Non-cardiac causes accounted for the majority of deaths at follow-up.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345 · cited 4×
“Concerning neurologic events, our findings are consistent with previous European registries,(7,8,9,11) but disagree with those reported in PARTNER cohort A, in which almost the 40% of neurologic events occurred from 30 days up to 1 year.(3) Three possible explanations could be hypothesized: first, the higher percentag…”
ResultInfluentialChronic Kidney Disease and Mortality Risk: A Systematic Review
Tonelli, M., Wiebe, N., Culleton, B., House, A., Rabbat, C., Fok, M., McAlister, F., & Garg, A. X. (2006) · Journal of the American Society of Nephrology · doi:10.1681/asn.2005101085 · Cited by 1,658
Murphy, G. J., Reeves, B. C., Rogers, C. A., Rizvi, S. I. A., Culliford, L., & Angelini, G. D. (2007) · Circulation · doi:10.1161/circulationaha.107.698977 · Cited by 1,371 · cited 1×
“Both stroke and bleedings are well-established predictors of poor outcome at follow-up.(23,24) In this analysis, the 30-day incidence of stroke and bleeding of 2.”
BackgroundLeon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M., Mehran, R., Miller, C., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq406 · Cited by 1,219
Tamburino, C., Capodanno, D., Ramondo, A., Petronio, A. S., Ettori, F., Santoro, G., Klugmann, S., Bedogni, F., Maisano, F., Marzocchi, A., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.946533 · Cited by 1,124
Self-citationRodés-Cabau, J., Webb, J. G., Cheung, A., Ye, J., Dumont, E., Feindel, C. M., Osten, M., Natarajan, M. K., Velianou, J. L., Martucci, G., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.014 · Cited by 974
Moat, N. E., Ludman, P., de Belder, M. A., Bridgewater, B., Cunningham, A. D., Young, C. P., Thomas, M., Kovac, J., Spyt, T., MacCarthy, P. A., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.050 · Cited by 884 · cited 1×
“Finally, Moat et al.(20) reported 2-year data of the UK-TAVI Registry, which collected data of both self-expanding and balloon-expandable prostheses.”
BackgroundVahanian, A., Alfieri, O., Al-Attar, N., Antunes, M., Bax, J., Cormier, B., Cribier, A., De Jaegere, P., Fournial, G., Kappetein, A. P., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn183 · Cited by 719
Self-citationTranscatheter aortic valve implantation: first results from a multi-centre real-world registry
Zahn, R., Gerckens, U., Grube, E., Linke, A., Sievert, H., Eggebrecht, H., Hambrecht, R., Sack, S., Hauptmann, K. E., Richardt, G., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq339 · Cited by 596
Self-citationEltchaninoff, H., Prat, A., Gilard, M., Leguerrier, A., Blanchard, D., Fournial, G., Iung, B., Donzeau-Gouge, P., Tribouilloy, C., Debrux, J.-L., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq261 · Cited by 554
Self-citationJournal of Heart Valve Disease
(2024) · Journal of Heart Valve Disease · doi:10.47310/jhvd · Cited by 525
Thomas, M., Schymik, G., Walther, T., Himbert, D., Lefèvre, T., Treede, H., Eggebrecht, H., Rubino, P., Colombo, A., Lange, R., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.001545 · Cited by 524
Self-citationBagur, R., Webb, J. G., Nietlispach, F., Dumont, E., De Larochelliere, R., Doyle, D., Masson, J.-B., Gutierrez, M. J., Clavel, M.-A., Bertrand, O. F., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp552 · Cited by 477
Appelros, P., Nydevik, I., & Viitanen, M. (2003) · Stroke · doi:10.1161/01.str.0000047852.05842.3c · Cited by 438
Petronio, A. S., De Carlo, M., Bedogni, F., Marzocchi, A., Klugmann, S., Maisano, F., Ramondo, A., Ussia, G. P., Ettori, F., Poli, A., et al. (2010) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.109.930453 · Cited by 290
Self-citationJournal of Invasive Cardiology
(2023) · The Journal of invasive cardiology/The journal of invasive cardiology · doi:10.25270/jic · Cited by 285
Gurvitch, R., Wood, D. A., Tay, E. L., Leipsic, J., Ye, J., Lichtenstein, S. V., Thompson, C. R., Carere, R. G., Wijesinghe, N., Nietlispach, F., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.948877 · Cited by 258
Buellesfeld, L., Gerckens, U., Schuler, G., Bonan, R., Kovac, J., Serruys, P. W., Labinaz, M., den Heijer, P., Mullen, M., Tymchak, W., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.11.044 · Cited by 196
Percutaneous transarterial aortic valve implantation: what do we know?
Webb, J., & Cribier, A. G. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq453 · Cited by 154
Roques, F., Nashef, S. A. M., & Michel, P. (2001) · PubMed · Cited by 138
An Embolic Deflection Device for Aortic Valve Interventions
Nietlispach, F., Wijesinghe, N., Gurvitch, R., Tay, E. L. W., Carpenter, J. P., Burns, C. A., Wood, D. A., & Webb, J. G. (2010) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2010.05.022 · Cited by 136
Gurvitch, R., Toggweiler, S., Willson, A. B., Wijesinghe, N., Cheung, A. W., Wood, D. A., Ye, J., & Webb, J. G. (2011) · EuroIntervention · doi:10.4244/eijv7i1a10 · Cited by 114
Kodali, S., O’Neill, W. W., Moses, J. W., Williams, M. R., Smith, C. R., Tuzcu, M., Svensson, L. G., Kapadia, S. R., Hanzel, G. S., Kirtane, A. J., et al. (2011) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2010.11.034 · Cited by 78
A crucial factor in shared decision making: the team approach
Head, S. J., Bogers, A. J. J. C., Serruys, P. W. J. C., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60775-7 · Cited by 40
Tamburino, C., Barbanti, M., Capodanno, D., Sarkar, K., Cammalleri, V., Scarabelli, M., Mulè, M., Immè, S., Aruta, P., & Ussia, G. P. (2011) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.23100 · Cited by 34
Self-citation
Cited by
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., Mieghem, N. M. V., Blackstone, E., Brott, T., Cohen, D., Cutlip, D. E., van Es, G., et al. (2012) · doi:10.48350/15011 · Cited by 3,368
Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement
Kodali, S. K., Williams, M. R., Smith, C. R., Svensson, L. G., Webb, J. G., Makkar, R. R., Fontana, G. P., Dewey, T. M., Thourani, V. H., Pichard, A. D., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1200384 · Cited by 2,282
Updated Standardized Endpoint Definitions for Transcatheter Aortic Valve Implantation
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., van Mieghem, N. M., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G.-A., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.09.001 · Cited by 1,668
Kappetein, A. P., Head, S. J., Genereux, P., Piazza, N., van Mieghem, N. M., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G.-A., et al. (2012) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezs533 · Cited by 1,601
Transcatheter Aortic-Valve Replacement for Inoperable Severe Aortic Stenosis
Makkar, R. R., Fontana, G. P., Jilaihawi, H., Kapadia, S., Pichard, A. D., Douglas, P. S., Thourani, V. H., Babaliaros, V. C., Webb, J. G., Herrmann, H. C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1202277 · Cited by 1,342
Metadata
- Authors
- Ussia, G. P., Barbanti, M., Petronio, A. S., Tarantini, G., Ettori, F., Colombo, A., Violini, R., Ramondo, A., Santoro, G., Klugmann, S., Bedogni, F., Maisano, F., Marzocchi, A., Poli, A., De Carlo, M., Napodano, M., Fiorina, C., De Marco, F., Antoniucci, D., de Cillis, E., Capodanno, D., Tamburino, C., & on behalf of the CoreValve Italian Registry Investigators
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-01-12
- Volume
- 33
- Issue
- 8
- Pages
- 969-976
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2110226194
- Cited by
- 284
- References
- 26
- FWCI
- 36.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.