Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 258

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Transcatheter Aortic Valve Implantation: Durability of Clinical and Hemodynamic Outcomes Beyond 3 Years in a Large Patient Cohort

Gurvitch, R., Wood, D.A., Tay, E.L., Leipsic, J., Ye, J., Lichtenstein, S.V., Thompson, C.R., Carere, R.G., Wijesinghe, N., Nietlispach, F., Boone, R.H., Lauck, S., Cheung, A., Webb, J.G.·2010·Circulation

Abstract

Background—: Although short- and medium-term outcomes after transcatheter aortic valve implantation are encouraging, long-term data on valve function and clinical outcomes are limited. Methods and Results—: Consecutive high-risk patients who had been declined as surgical candidates because of comorbidities but who underwent successful transcatheter aortic valve implantation with a balloon-expandable valve between January 2005 and December 2006 and survived past 30 days were assessed. Clinical, echocardiographic, and computed tomographic follow-up examinations were performed. Seventy patients who underwent successful procedures and survived longer than 30 days were evaluated at a minimum follow-up of 3 years. At a median follow-up of 3.7 years (interquartile range 3.4 to 4.3 years), survival was 57%. Survival at 1, 2, and 3 years was 81%, 74%, and 61%, respectively. Freedom from reoperation was 98.5% (1 patient with endocarditis). During this early procedural experience, 11 patients died within 30 days, and 8 procedures were unsuccessful. When these patients were included, overall survival was 51%. Transaortic pressure gradients increased from 10.0 mm Hg (interquartile range 8.0 to 12.0 mm Hg) immediately after the procedure to 12.1 mm Hg (interquartile range 8.6 to 16.0 mm Hg) after 3 years ( P =0.03). Bioprosthetic valve area decreased from a mean of 1.7±0.4 cm 2 after the procedure to 1.4±0.3 cm 2 after 3 years ( P <0.01). Aortic incompetence after implantation was trivial or mild in 84% of cases and remained unchanged or improved over time. There were no cases of structural valvular deterioration, stent fracture, deformation, or valve migration. Conclusions—: Transcatheter aortic valve implantation demonstrates good medium- to long-term durability and preserved hemodynamic function, with no evidence of structural failure. The procedure appears to offer an adequate and lasting resolution of aortic stenosis in selected patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.110.948877

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 258

Metadata

Authors
Gurvitch, R., Wood, D. A., Tay, E. L., Leipsic, J., Ye, J., Lichtenstein, S. V., Thompson, C. R., Carere, R. G., Wijesinghe, N., Nietlispach, F., Boone, R. H., Lauck, S., Cheung, A., & Webb, J. G.
Venue
Circulation
Published
2010-09-28
Volume
122
Issue
13
Pages
1319-1327
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2023617433
Cited by
258
References
2
FWCI
32.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transcatheter Aortic Valve Implantation: Durability of Clinical and Hemodynamic Outcomes Beyond 3 Years in a Large Patient Cohort. https://app.cochat.ai/papers/10.1161/circulationaha.110.948877
The paper
Gurvitch, R., Wood, D. A., Tay, E. L., Leipsic, J., Ye, J., Lichtenstein, S. V., Thompson, C. R., Carere, R. G., Wijesinghe, N., Nietlispach, F., Boone, R. H., Lauck, S., Cheung, A., & Webb, J. G. (2010). Transcatheter Aortic Valve Implantation: Durability of Clinical and Hemodynamic Outcomes Beyond 3 Years in a Large Patient Cohort. Circulation. https://doi.org/10.1161/circulationaha.110.948877

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.