Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
AIMS: Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient morbidity, healthcare costs, and possibly increased mortality. METHODS AND RESULTS: Population-based cohort study in all Danish patients who underwent a CIED procedure from May 2010 to April 2011. Data on complications were gathered on review of all patient charts while baseline data were obtained from the Danish Pacemaker and ICD Register. Adjusted risk ratios (aRRs) with 95% confidence intervals were estimated using binary regression. The study population consisted of 5918 consecutive patients. A total of 562 patients (9.5%) experienced at least one complication. The risk of any complication was higher if the patient was a female (aRR 1.3; 1.1-1.6), underweight (aRR 1.5; 1.1-2.3), implanted in a centre with an annual volume <750 procedures (0-249 procedures: aRR 1.6; 1.1-2.2, 250-499: aRR 2.0; 1.6-2.7, 500-749: aRR 1.5; 1.2-1.8), received a dual-chamber ICD (aRR 2.0; 1.4-2.7) or CRT-D (aRR 2.6; 1.9-3.4), underwent system upgrade or lead revision (aRR 1.3; 1.0-1.7), had an operator with an annual volume <50 procedures (aRR 1.9; 1.4-2.6), or underwent an emergency, out-of-hours procedure (aRR 1.5; 1.0-2.3). CONCLUSION: CIED complications are more frequent than generally acknowledged. Both patient- and procedure-related predictors may identify patients with a particularly high risk of complications. This information should be taken into account both in individual patient treatment and in the planning of future organization of CIED treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Despite great advancements in implantable cardiac pacemaker technology, complications from pacemaker leads continue to compromise nearly 10% of all implants1, 2.”
From Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system (2017) · cites this paper as [1]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · PubMed · Cited by 13,173
Obesity : Preventing and managing the global epidemic
Akram, D. S., Astrup, A. V., Atinmo, T., Boissin, J.-L., Bray, G. A., Carroll, K. N., Chitson, P., Chen, C., Dietz, W. H., Hill, J. O., et al. (2000) · Research at the University of Copenhagen (University of Copenhagen) · Cited by 12,945
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht150 · Cited by 2,809
Self-citationPoole, J. E., Gleva, M. J., Mela, T., Chung, M. K., Uslan, D. Z., Borge, R., Gottipaty, V., Shinn, T., Dan, D., Feldman, L. A., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.976076 · Cited by 790
Udo, E. O., Zuithoff, N. P. A., van Hemel, N. M., de Cock, C. C., Hendriks, T., Doevendans, P. A., & Moons, K. G. M. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.014 · Cited by 597
Johansen, J. B., Jorgensen, O. D., Moller, M., Arnsbo, P., Mortensen, P. T., & Nielsen, J. C. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq497 · Cited by 376
Self-citationReynolds, M. R., Cohen, D. J., Kugelmass, A. D., Brown, P. P., Becker, E. R., Culler, S. D., & Simon, A. W. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.02.049 · Cited by 291
Risk Factor Analysis of Permanent Pacemaker Infection
Sohail, M. R., Uslan, D. Z., Khan, A. H., Friedman, P. A., Hayes, D. L., Wilson, W. R., Steckelberg, J. M., Stoner, S. M., & Baddour, L. M. (2007) · Clinical Infectious Diseases · doi:10.1086/518889 · Cited by 288
Evaluation of Early Complications Related to De Novo Cardioverter Defibrillator Implantation
Lee, D. S., Krahn, A. D., Healey, J. S., Birnie, D., Crystal, E., Dorian, P., Simpson, C. S., Khaykin, Y., Cameron, D., Janmohamed, A., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.029 · Cited by 228
Complications arising after implantation of DDD pacemakers: the MOST experience
Ellenbogen, K. A., Hellkamp, A. S., Wilkoff, B. L., Camunãs, J. L., Love, J. C., Hadjis, T. A., Lee, K. L., & Lamas, G. A. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(03)00844-0 · Cited by 210
Research works printed but not linked: 5
- 2006, Journal of the American College of Cardiology, 47, 2493, 10.1016/j.jacc.2006.02.049 · DOI · Paper page
- 2005, Journal of the American College of Cardiology, 46, 1536, 10.1016/j.jacc.2005.04.063 · DOI · Paper page
- 2007, Clinical Infectious Diseases, 45, 166, 10.1086/518889 · DOI · Paper page
- 2011, Circulation: Arrhythmia and Electrophysiology, 4, 136, 10.1161/CIRCEP.110.959791 · DOI · Paper page
- 2011, Circulation: Cardiovascular Quality and Outcomes, 4, 549, 10.1161/CIRCOUTCOMES.110.959205 · DOI
Cited by
Items 201–300 of 871
Sperzel, J., Hamm, C. W., & Hain, A. (2018) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-018-0598-3 · Cited by 25
Rashtian, M. Y., Banker, R., Neužil, P., Breeman, K. T. N., Nee, P., Badie, N., Victorine, K., LIGON, D. A., Rippy, M. K., ELDADAH, Z. A., et al. (2022) · Heart Rhythm · doi:10.1016/j.hrthm.2022.01.021 · Cited by 27
Mitacchione, G., Schiavone, M., Gasperetti, A., Arabia, G., Tundo, F., Breitenstein, A., Montemerlo, E., Monaco, C., Gulletta, S., Palmisano, P., et al. (2023) · Heart Rhythm · doi:10.1016/j.hrthm.2023.07.061 · Cited by 24
Feasibility of ultrasound-guided vascular access during cardiac implantable device placement
Lin, J. Y., Adsit, G. S., Barnett, A., Tattersall, M. C., Field, M. E., & Wright, J. M. (2017) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-017-0273-3 · Cited by 24
An Overview of Clinical Outcomes in Transvenous and Subcutaneous ICD Patients
Baalman, S. W. E., Quast, A. B. E., Brouwer, T. F., & Knops, R. E. (2018) · Current Cardiology Reports · doi:10.1007/s11886-018-1021-8 · Cited by 24
Worldwide Chronic Retrieval Experience of Helix-Fixation Leadless Cardiac Pacemakers
Neužil, P., Exner, D. V., Knops, R. E., Cantillon, D. J., Defaye, P., Banker, R., Friedman, P. A., Hubbard, C., Delgado, S. M., Bulusu, A., et al. (2025) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2024.10.094 · Cited by 30
Ravaux, J. M., Mauro, M. D., Vernooy, K., Hof, A. W. J. V. ’., Veenstra, L. F., Kats, S., Maessen, J. G., & Lorusso, R. (2021) · JTCVS Open · doi:10.1016/j.xjon.2021.02.002 · Cited by 23
Chubb, H., Mah, D. Y., Shah, M. J., Lin, K. Y., Peng, D. M., Hale, B., May, L. J., Etheridge, S. P., Goodyer, W. R., Ceresnak, S. R., et al. (2024) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2023.11.008 · Cited by 24
Turagam, M. K., Nagarajan, D. V., Bartuś, K., Makkar, A., & Swarup, V. (2017) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-017-0235-9 · Cited by 23
Mortality and Cerebrovascular Events After Heart Rhythm Disorder Management Procedures
Lee, J. Z., Ling, J., Diehl, N. N., Hodge, D. O., Padmanabhan, D., Killu, A. M., Madhavan, M., Noseworthy, P. A., Kapa, S., McLeod, C. J., et al. (2018) · Circulation · doi:10.1161/circulationaha.117.030523 · Cited by 22
Budano, C., Garrone, P., Castagno, D., Bissolino, A., Andreis, A., Bertolo, L., Mazzini, D., Bergamasco, L., Marra, S., & Gaïta, F. (2019) · International Journal of Cardiology · doi:10.1016/j.ijcard.2019.04.020 · Cited by 26
Palmisano, P., Ziacchi, M., Ammendola, E., D’Onofrio, A., Dell’Era, G., Laffi, M., Biffi, M., Nigro, G., Bianchi, W., Prenna, E., et al. (2021) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15080 · Cited by 22
Fauchier, L., Alonso, C., Anselme, F., Blangy, H., Bordachar, P., Bovéda, S., Clémenty, N., Defaye, P., Deharo, J., Friocourt, P., et al. (2016) · Archives of cardiovascular diseases · doi:10.1016/j.acvd.2016.04.004 · Cited by 24
Leadless Pacemakers – Implant, Explant and Long-Term Safety and Efficacy Data
Kancharla, K., Deshmukh, A. J., & Friedman, P. A. (2017) · Journal of Atrial Fibrillation · doi:10.4022/jafib.1581 · Cited by 23
Pacing devices to treat bradycardia: current status and future perspectives
Biffi, M., Capobianco, C., Spadotto, A., Bartoli, L., Sorrentino, S., Minguzzi, A., Piemontese, G. P., Angeletti, A., Toniolo, S., & Statuto, G. (2020) · Expert Review of Medical Devices · doi:10.1080/17434440.2021.1866543 · Cited by 26
Boriani, G., Biagini, E., Ziacchi, M., Malavasi, V. L., Vitolo, M., Talarico, M., Mauro, E., Gorlato, G., & Lattanzi, G. (2018) · Nucleus · doi:10.1080/19491034.2018.1506680 · Cited by 23
Does Age Influence Cardiac Resynchronization Therapy Use and Outcome?
Heidenreich, P. A., Tsai, V., Bao, H., Curtis, J. P., Goldstein, M. K., Curtis, L. H., Hernandez, A. F., Peterson, P. N., Turakhia, M. P., & Masoudi, F. A. (2015) · JACC Heart Failure · doi:10.1016/j.jchf.2015.01.012 · Cited by 21
Shakya, S., Matsui, H., Fushimi, K., & Yasunaga, H. (2017) · Journal of Cardiology · doi:10.1016/j.jjcc.2017.02.013 · Cited by 24
Holcman, K., Rubiś, P., Stępień, A., Graczyk, K., Podolec, P. S., & Kostkiewicz, M. (2021) · Journal of Personalized Medicine · doi:10.3390/jpm11101016 · Cited by 22
Gardas, R., Golba, K. S., Soral, T., Biernat, J., Kulesza, P., Sajdok, M., & Zub, K. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11195723 · Cited by 23
Upper airway stimulation for obstructive sleep apnea: The surgical learning curve
Murphey, A. W., Baker, A. B., Soose, R. J., Padyha, T. A., Nguyen, S. A., Xiao, C. C., & Gillespie, M. B. (2015) · The Laryngoscope · doi:10.1002/lary.25537 · Cited by 21
da Silva, K. R., Albertini, C. M. D. M., Crevelari, E. S., de Carvalho, E. I. J., Fiorelli, A. I., Filho, M. M., & Costa, R. (2016) · Arquivos Brasileiros de Cardiologia · doi:10.5935/abc.20160129 · Cited by 24
Martínez‐Sande, J. L., García‐Seara, J., Rodríguez‐Mañero, M., Fernández-López, X. A., Melchor, L. G., Diéguez, A. R., González-Ferreiro, R., & González‐Juanatey, J. R. (2016) · Revista Española de Cardiología · doi:10.1016/j.recesp.2016.09.011 · Cited by 22
Zeitler, E. P., Patel, D., Hasselblad, V., Sanders, G. D., & Al‐Khatib, S. M. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.04.003 · Cited by 20
Implantation of the Micra Transcatheter Pacing System: Initial Experience in a Single Spanish Center
Pachón, M., Puchol, A., Akerström, F. O., Padial, L. R., & Arias, M. A. (2016) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2015.11.020 · Cited by 20
Implante de marcapasos sin cables transcatéter Micra: experiencia inicial en un centro español
Pachón, M., Puchol, A., Akerström, F. O., Padial, L. R., & Arias, M. A. (2016) · Revista Española de Cardiología · doi:10.1016/j.recesp.2015.11.022 · Cited by 20
Palmisano, P., Iacopino, S., Vivo, S. D., D’Agostino, C., Tomasi, L., Startari, U., Ziacchi, M., Pisanò, E., Santobuono, V. E., Caccavo, V. P., et al. (2022) · International Journal of Cardiology · doi:10.1016/j.ijcard.2022.07.040 · Cited by 38
Living with a pacemaker: patient-reported outcome of a pacemaker system
Magnusson, P., & Liv, P. (2018) · BMC Cardiovascular Disorders · doi:10.1186/s12872-018-0849-6 · Cited by 25
Developing a Minimum Data Set (MDS) for Cardiac Electronic Implantable Devices Implantation
Kazemi-Arpanahi, H., Vasheghani‐Farahani, A., Baradaran, A., Mohammadzadeh, N., & Ghazisaeedi, M. (2018) · Acta Informatica Medica · doi:10.5455/aim.2018.26.164-168 · Cited by 19
Christensen, A. H., Platonov, P. G., Svensson, A., Jensen, H. K., Rootwelt‐Norberg, C., Dahlberg, P., Madsen, T., Frederiksen, T. C., Heliö, T. M., Haugaa, K. H., et al. (2021) · EP Europace · doi:10.1093/europace/euab112 · Cited by 19
Disertori, M., Gulizia, M. M., Casolo, G., Delise, P., Lenarda, A. D., Tano, G. D., Lunati, M., Mestroni, L., Salerno‐Uriarte, J. A., & Tavazzi, L. (2016) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000000368 · Cited by 20
New Insights into Predictors of Cardiac Implantable Electronic Device Infection
Sadeghi, H., Alizadeh‐Diz, A., Fazelifar, A., Emkanjoo, Z., & Haghjoo, M. (2018) · Texas Heart Institute Journal · doi:10.14503/thij-17-6300 · Cited by 24
Gillam, M., Pratt, N. L., Inacio, M. C. S., Shakib, S., Sanders, P., Lau, D. H., & Roughead, E. E. (2018) · Clinical Cardiology · doi:10.1002/clc.23091 · Cited by 22
Complications and associated healthcare costs of transvenous cardiac pacemakers in Germany
Ludwig, S., Theis, C., Wolff, C., Nicolle, E., Witthohn, A., & Götte, A. (2019) · Journal of Comparative Effectiveness Research · doi:10.2217/cer-2018-0114 · Cited by 19
Bovéda, S., Marijon, É., Lenarczyk, R., Iliodromitis, K. E., Marín, F. R., Defaye, P., Solnon, A., Dagres, N., & Potpara, T. (2020) · EP Europace · doi:10.1093/europace/euz357 · Cited by 22
Micro- and nanoscale biophysical cues for cardiovascular disease therapy
Mohindra, P., & Desai, T. A. (2021) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2021.102365 · Cited by 21
Keil, L. D., Chevalier, C. M., Kirchhof, P. F., Blankenberg, S., Lund, G., Müllerleile, K., & Magnussen, C. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22137115 · Cited by 20
Vijayarajan, V., Kritharides, L., Brieger, D. B., Cheng, Y.-Y., Chow, V., & Ng, A. C. C. (2022) · PLoS ONE · doi:10.1371/journal.pone.0272305 · Cited by 20
Sjöblom, J., Kalm, T., Gadler, F., Ljung, L., Frykman, V., Rosenqvist, M., Platonov, P. G., & Borgquist, R. (2014) · EP Europace · doi:10.1093/europace/euu219 · Cited by 19
Diemberger, I., Parisi, Q., Filippo, P. D., Narducci, M. L., Zanon, F., Potenza, D. R., Ciaramitaro, G., Malacrida, M., Boriani, G., & Biffi, M. (2015) · Clinical Cardiology · doi:10.1002/clc.22440 · Cited by 18
Safety and efficacy of applying a low-dose radiation fluoroscopy protocol in device implantations
Attanasio, P., Mirdamadi, M., Wielandts, J., Pieske, B. M., Blaschke, F., Boldt, L., Jaïs, P., Haverkamp, W., & Huemer, M. (2016) · EP Europace · doi:10.1093/europace/euw189 · Cited by 20
Barra, S., Duehmke, R. M., Providencia, R. A., Marijon, É., Bovéda, S., Virdee, M., Heck, P. M., Fynn, S. P., Begley, D., Grace, A. A., et al. (2016) · EP Europace · doi:10.1093/europace/euw321 · Cited by 17
Bradyarrhythmias and pacemakers
Honarbakhsh, S., Hunter, L., CHOW, A. W. C., & Hunter, R. J. (2018) · BMJ · doi:10.1136/bmj.k642 · Cited by 23
Validez y confiabilidad del cuestionario Florida versión en español
Sierra, D. M. C., González-Consuegra, R. V., & Olaya-Sánchez, A. (2018) · Revista Colombiana de Cardiología · doi:10.1016/j.rccar.2017.12.018 · Cited by 50
Management of anticoagulation in patients undergoing leadless pacemaker implantation
Antonio, R. S., Chipa, F., Apolo, J., Linhart, M., Trotta, O., Pujol‐López, M., Niebla, M., Alarcón, F., Trucco, E., Arbelo, E., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.05.016 · Cited by 17
Performance of the Micra cardiac pacemaker in nonagenarians
Amrani, A. E., Campos, B., Alonso‐Martín, C., Palmero, M. J. G., Font, E. R., Weidmann, Z. M., Alcalde, Ó., Méndez-Zurita, F. J., Santaló, M., Viamonte, H. T. E., et al. (2019) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2019.06.001 · Cited by 17
One-Year Safety and Performance of a Dual-Chamber Leadless Pacemaker
Knops, R. E., Ip, J. E., Doshi, R. N., Exner, D. V., Defaye, P., Canby, R. C., Bongiorni, M. G., Shoda, M., Hindricks, G., Neužil, P., et al. (2025) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.124.013619 · Cited by 24
Leadless Pacing: Current State and Future Direction
Merkel, M., Grotherr, P., Radzewitz, A., & Schmitt, C. (2017) · Cardiology and Therapy · doi:10.1007/s40119-017-0097-3 · Cited by 18
Skjøth, F., Vadmann, H., Hjortshøj, S. P., Riahi, S., Lip, G. Y. H., & Larsen, T. B. (2018) · International Journal of Clinical Practice · doi:10.1111/ijcp.13258 · Cited by 17
Sex-Related Procedural Aspects and Complications in CRT Survey II
Auricchio, A., Gasparini, M., Linde, C. M., Dobreanu, D., Cano, Ó., Sterlinski, M. M., Bogale, N., Stellbrink, C., Refaat, M. M., Blomström‐Lundqvist, C., et al. (2019) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2019.06.003 · Cited by 17
Lenarczyk, R., Bovéda, S., Mansourati, J., Russo, V., Marijon, É., Lane, D. A., Dagres, N., & Potpara, T. (2020) · EP Europace · doi:10.1093/europace/euaa023 · Cited by 17
Archontakis, S., Oikonomou, E. K., Sideris, K., Laina, A., Tirovola, D., Paraskevopoulou, D., Kostakis, P. G., Doundoulakis, I., Αρσένος, Π., Ntalakouras, I., et al. (2022) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-022-01319-5 · Cited by 18
Leadless cardiac ventricular pacing using helix fixation: Step‐by‐step guide to implantation
Laczay, B., Aguilera, J., & Cantillon, D. J. (2022) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15785 · Cited by 18
Contemporary trends of leadless pacemaker implantation in the United States
Khan, M. Z., Nassar, S., Nguyen, A., Khan, M. U., Sattar, Y., Alruwaili, W., Gonuguntla, K., Mazek, H., Asad, Z. U. A., Agarwal, S., et al. (2024) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16295 · Cited by 21
Devices for management of sudden cardiac death: Successes, challenges and perspectives
Dagres, N., & Hindricks, G. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.03.053 · Cited by 16
2017 ACC/HRS Lifelong Learning Statement for Clinical Cardiac Electrophysiology Specialists
Tracy, C. M., Crossley, G. H., Bunch, T. J., Chow, G. V., Leiserowitz, A., Indik, J. H., Kusumoto, F. M., Mendes, L. A., Munger, T. M., Murali, S., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.11.016 · Cited by 16
Technological and Clinical Challenges in Lead Placement for Cardiac Rhythm Management Devices
Albatat, M., Bergsland, J., Arevalo, H., Odland, H. H., Bose, P., Halvorsen, P. S., & Balasingham, I. (2019) · Annals of Biomedical Engineering · doi:10.1007/s10439-019-02376-0 · Cited by 21
Mattsson, G., & Magnusson, P. (2019) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13869 · Cited by 16
Tonegawa‐Kuji, R., Kanaoka, K., Mori, M., Nakai, M., & Iwanaga, Y. (2022) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2022.08.002 · Cited by 16
Horst, I. A., Kuijpers, Y. A. M., Sant, J. V. ’., Tuinenburg, A. E., Cramer, M. J., & Meine, M. (2015) · Netherlands Heart Journal · doi:10.1007/s12471-015-0771-9 · Cited by 16
Patel, N., Viles-González, J. F., Agnihotri, K., Arora, S., Patel, N., Aneja, E., Shah, M. K., Badheka, A. O., Pothineni, N. V. K., Kancharla, K., et al. (2018) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13701 · Cited by 15
Mascheroni, J., Stockburger, M. A., Patwala, A., Mont, L., Rao, A., Retzlaff, H., Garweg, C., Verbelen, T., & Gallagher, A. G. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.22750 · Cited by 18
Pulsed electron avalanche knife (PEAK) PlasmaBlade™ in pacemaker and defibrillator procedures
Kaya, E., Totzeck, M., & Rassaf, T. (2017) · European journal of medical research · doi:10.1186/s40001-017-0292-7 · Cited by 16
Archontakis, S., Sideris, K., Aggeli, K. D., Gatzoulis, K. A., Demosthenous, M., Tolios, P., Lozos, V., Koumallos, N., Limperiadis, D., Tousoulis, D. M., et al. (2018) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13804 · Cited by 17
Hackett, G. L., Aziz, F., Samii, S. M., & Imundo, J. R. (2021) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2021.120403 · Cited by 15
Trongtorsak, A., Kewcharoen, J., Thangjui, S., Worapongsatitaya, P., Yodsuwan, R., & Navaravong, L. (2021) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14368 · Cited by 17
Oosterwerff, E. F. J., Salavati, A., Lenssen, M., Delnoy, P. P. H. M., Adiyaman, A., & Elvan, A. (2022) · Heart Rhythm · doi:10.1016/j.hrthm.2022.01.028 · Cited by 18
Bertelli, M., Toniolo, S., Ziacchi, M., Gasperetti, A., Schiavone, M., Arosio, R., Capobianco, C., Mitacchione, G., Statuto, G., Angeletti, A., et al. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11206071 · Cited by 15
Rella, V., Parati, G., & Crotti, L. (2020) · Frontiers in Pediatrics · doi:10.3389/fped.2020.00139 · Cited by 15
Leadless Pacemakers: State of the Art and Selection of the Ideal Candidate
Blank, E. A., El‐Chami, M. F., & Wenger, N. K. (2023) · Current Cardiology Reviews · doi:10.2174/1573403x19666230331094647 · Cited by 15
Andò, K., Inoue, K., Harada, T., Shizuta, S., Yoshida, Y., KUSANO, K. F., Onuki, T., Watari, Y., Fukui, A., Sasaki, S., et al. (2023) · Circulation Journal · doi:10.1253/circj.cj-23-0269 · Cited by 14
Magnusson, P., Gadler, F., Liv, P., & Mörner, S. (2015) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12750 · Cited by 19
Temporal Trends Over a Decade of Defibrillator Therapy for Primary Prevention in Community Practice
Bovéda, S., Narayanan, K., Jacob, S., Providencia, R. A., Algalarrondo, V., Bouzeman, A., Beganton, F., Defaye, P., Perier, M., Sadoul, N., et al. (2017) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13198 · Cited by 14
Patel, B. D., Sablani, N., Garg, J., Chaudhary, R., Shah, M. K., Gupta, R., Nazir, T. F., Bozorgnia, B., Padala, S. K., Gunda, S., et al. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2018.01.006 · Cited by 16
Unexpected high failure rate of a specific MicroPort/LivaNova/Sorin pacing lead
Haeberlin, A., Anwander, M.-T., Kueffer, T., Tholl, M., Baldinger, S. H., Servatius, H., Lam, A., Franzeck, F., Asatryan, B., Zurbuchen, A., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2020.08.010 · Cited by 14
Frausing, M. H. J. P., Nielsen, J. C., Johansen, J. B., Jørgensen, O. D., Gerdes, C., Olsen, T., & Kronborg, M. B. (2021) · EP Europace · doi:10.1093/europace/euab207 · Cited by 14
Self-citationRusso, V., Rago, A., Ruggiero, V., Cavaliere, F., Bianchi, V., Ammendola, E., Papa, A. A., Tavoletta, V., Vivo, S. D., Golino, P., et al. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.879918 · Cited by 16
Leadless pacemakers: leading us into the future?: Figure 1
Mela, T., & Singh, J. P. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv261 · Cited by 13
“Notably, almost 10% of the 700 000 pacemakers implanted annually worldwide are associated with lead-related problems.(1,2) This, in turn, has created the need for a leadless pacemaker system.”
BackgroundDöring, M., Hienzsch, L., Ebert, M., Lucas, J., Dagres, N., Kühl, M., Hindricks, G., Knopp, H., & Richter, S. (2019) · International Journal of Cardiology · doi:10.1016/j.ijcard.2019.12.044 · Cited by 15
Timing of pacemaker and ICD implantation in LMNA mutation carriers
Ollila, L., Nikus, K. C., Parikka, H. J., Weckström, S., & Tiina, H. (2021) · Open Heart · doi:10.1136/openhrt-2021-001622 · Cited by 13
Frausing, M. H. J. P., Bæk, A. L., Kristensen, J., Gerdes, C., Nielsen, J. C., & Kronborg, M. B. (2023) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-023-01488-x · Cited by 16
Self-citationEpilepsy–heart syndrome: Concept, clinical context, and opportunity for integrated care
Mbizvo, G. K., Buchan, I. E., Marson, A. G., & Lip, G. Y. H. (2025) · Epilepsia · doi:10.1111/epi.18356 · Cited by 13
Complications and prognosis of patients undergoing apical or septal right ventricular pacing
Spath, N. B., Wang, K., Venkatasumbramanian, S., Fersia, O., Newby, D. E., Lang, C., Grubb, N. R., & Dweck, M. R. (2019) · Open Heart · doi:10.1136/openhrt-2018-000962 · Cited by 17
Enache, B., Șoșdean, R., Macarie, R. I., Dodinot, B., & Pescariu, S. (2019) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13742 · Cited by 13
Rendimiento del marcapasos cardiaco Micra en nonagenarios
Amrani, A. E., Campos, B., Alonso‐Martín, C., Palmero, M. J. G., Font, E. R., Weidmann, Z. M., Alcalde, Ó., Méndez-Zurita, F. J., Santaló, M., Viamonte, H. T. E., et al. (2019) · Revista Española de Cardiología · doi:10.1016/j.recesp.2019.06.008 · Cited by 13
Forleo, G. B., Gasperetti, A., Ricciardi, D., Curnis, A., Bertaglia, E., Calò, L., Pignalberi, C., Calzolari, V., Ribatti, V., Lavalle, C., et al. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14254 · Cited by 12
Shaik, N. A., Drucker, M., Pierce, C. A., Duray, G. Z., Gillett, S., Miller, C., Harrell, C., & Thomas, G. (2020) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14552 · Cited by 13
Mendoza, P. A., Narula, S., McIntyre, W. F., Whitlock, R. P., Birnie, D. H., Healey, J. S., & Belley‐Côté, E. P. (2020) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14091 · Cited by 13
Iavarone, M., Rago, A., Nigro, G., Golino, P., & Russo, V. (2022) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14584 · Cited by 13
Breeman, K. T. N., Beurskens, N. E. G., Driessen, A. H. G., Wilde, A. A. M., Tjong, F. V. Y., & Knops, R. E. (2022) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-022-01457-w · Cited by 13
His Bundle Pacing: Techniques and Outcomes
Kronborg, M. B., & Nielsen, J. C. (2016) · Current Cardiology Reports · doi:10.1007/s11886-016-0748-3 · Cited by 12
Self-citationPlacement of Cardiac PacemaKEr Trial (POCKET) – Rationale and Design: A Randomized Controlled Trial
Magnusson, P., Wennström, L., Kastberg, R., & Liv, P. (2017) · Heart International · doi:10.5301/heartint.5000235 · Cited by 13
Trends in service time of pacemakers in the Netherlands: a long-term nationwide follow-up study
de Vries, L. M., Leening, M. J. G., Dijk, W. A., Hooijschuur, C. A. M., Stricker, B. H. C., & van Hemel, N. M. (2017) · Netherlands Heart Journal · doi:10.1007/s12471-017-1024-x · Cited by 13
Döring, M., Müssigbrodt, A., Ebert, M., Bode, K., Lucas, J., Dagres, N., Hindricks, G., & Richter, S. (2020) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14056 · Cited by 12
Li, Y., Xing, Q., Xing, Q., Xiaokereti, J., Chen, C., Zhang, J., Zhou, X., Lu, Y.-M., Tang, B., & Zhou, X. (2022) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-022-01399-3 · Cited by 16
Nasir, M., Dejene, K., Bedru, M., Ahmed, M., & Markos, S. (2024) · BMC Cardiovascular Disorders · doi:10.1186/s12872-024-04068-7 · Cited by 14
Vonthein, R., Baldauf, B. J., Borov, S., Lau, E. W., Giaccardi, M., Assadian, O., Haddad, C., Chevalier, P., Bode, K., Foley, P., et al. (2024) · Journal of Cardiothoracic Surgery · doi:10.1186/s13019-024-03059-1 · Cited by 12
Amir, O., Adamopoulos, S. N., Burri, H., Bayés‐Genís, A., Leclercq, C., Čikeš, M., Egorova, A. D., Peichl, P., Fudim, M., Rao, A., et al. (2025) · European Journal of Heart Failure · doi:10.1002/ejhf.3635 · Cited by 14
Self-citationCardiac device implantations in obese patients: Success rates and complications
Attanasio, P., Lacour, P., Ernert, A., Pieske, B. M., Haverkamp, W., Blaschke, F., Vedove, F. D., & Huemer, M. (2017) · Clinical Cardiology · doi:10.1002/clc.22650 · Cited by 16
Grabowski, M., Michalak, M., Gawalko, M. M., Gajda, S., Cacko, A., Januszkiewicz, Ł. J., Kołodzińska, A., Mitkowski, P. P., Duray, G. Z., & Opolski, G. (2018) · Cardiology Journal · doi:10.5603/cj.a2018.0075 · Cited by 12
Metadata
- Authors
- Kirkfeldt, R. E., Johansen, J. B., Nohr, E. A., Jorgensen, O. D., & Nielsen, J. C.
- Affiliations
- Odense University Hospital (DK)
- Aarhus University (DK)
- Aarhus University Hospital (DK)
- Corresponding author
- Kirkfeldt, R. E.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-12-17
- Volume
- 35
- Issue
- 18
- Pages
- 1186-1194
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- PMC
- PMC4012708
- OpenAlex
- W2109817867
- Cited by
- 871
- References
- 33
- Citations by year
- 2026: 68 · 2025: 73 · 2024: 68 · 2023: 84 · 2022: 94 · 2021: 66 · 2020: 71 · 2019: 68 · 2018: 92 · 2017: 74 · 2016: 46 · 2015: 50 · 2014: 16 · 2013: 1
- FWCI
- 25.63
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc
- Locations
- European Heart Journal (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- University of Southern Denmark Research Portal (University of Southern Denmark) (submittedVersion)
- Funders
- Hjerteforeningen
- Aarhus Universitet
- Aalborg Universitet
- Odense Universitetshospital
- Rigshospitalet
- Aalborg Universitetshospital
- Gangstedfonden
- Region Midtjylland
- Bispebjerg Hospital
- St. Jude Medical
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Emergency Medicine › Cardiac Arrest and Resuscitation
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Infective Endocarditis Diagnosis and Management
- Keywords
- cardiac implantable electronic devices, post-implantation complications, permanent pacemaker, cardiac resynchronization therapy, CRT-D, implantable cardioverter-defibrillator, dual-chamber ICD, lead revision, system upgrade, operator volume, hospital volume, risk factors
- MeSH terms
- Adolescent, Adult, Aged, Aged, 80 and over, Child, Child, Preschool, Denmark, Female, Humans, Infant, Infant, Newborn, Male, Middle Aged, Pacemaker, Artificial, Postoperative Complications, Prosthesis Failure, Risk Factors, Cohort Studies, Defibrillators, Implantable, Age Distribution, Sex Distribution, Device Removal, Young Adult, Cardiac Resynchronization Therapy Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.

