Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
AIMS: Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient morbidity, healthcare costs, and possibly increased mortality. METHODS AND RESULTS: Population-based cohort study in all Danish patients who underwent a CIED procedure from May 2010 to April 2011. Data on complications were gathered on review of all patient charts while baseline data were obtained from the Danish Pacemaker and ICD Register. Adjusted risk ratios (aRRs) with 95% confidence intervals were estimated using binary regression. The study population consisted of 5918 consecutive patients. A total of 562 patients (9.5%) experienced at least one complication. The risk of any complication was higher if the patient was a female (aRR 1.3; 1.1-1.6), underweight (aRR 1.5; 1.1-2.3), implanted in a centre with an annual volume <750 procedures (0-249 procedures: aRR 1.6; 1.1-2.2, 250-499: aRR 2.0; 1.6-2.7, 500-749: aRR 1.5; 1.2-1.8), received a dual-chamber ICD (aRR 2.0; 1.4-2.7) or CRT-D (aRR 2.6; 1.9-3.4), underwent system upgrade or lead revision (aRR 1.3; 1.0-1.7), had an operator with an annual volume <50 procedures (aRR 1.9; 1.4-2.6), or underwent an emergency, out-of-hours procedure (aRR 1.5; 1.0-2.3). CONCLUSION: CIED complications are more frequent than generally acknowledged. Both patient- and procedure-related predictors may identify patients with a particularly high risk of complications. This information should be taken into account both in individual patient treatment and in the planning of future organization of CIED treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Despite great advancements in implantable cardiac pacemaker technology, complications from pacemaker leads continue to compromise nearly 10% of all implants1, 2.”
From Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system (2017) · cites this paper as [1]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · PubMed · Cited by 13,173
Obesity : Preventing and managing the global epidemic
Akram, D. S., Astrup, A. V., Atinmo, T., Boissin, J.-L., Bray, G. A., Carroll, K. N., Chitson, P., Chen, C., Dietz, W. H., Hill, J. O., et al. (2000) · Research at the University of Copenhagen (University of Copenhagen) · Cited by 12,945
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht150 · Cited by 2,809
Self-citationPoole, J. E., Gleva, M. J., Mela, T., Chung, M. K., Uslan, D. Z., Borge, R., Gottipaty, V., Shinn, T., Dan, D., Feldman, L. A., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.976076 · Cited by 790
Udo, E. O., Zuithoff, N. P. A., van Hemel, N. M., de Cock, C. C., Hendriks, T., Doevendans, P. A., & Moons, K. G. M. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.014 · Cited by 597
Johansen, J. B., Jorgensen, O. D., Moller, M., Arnsbo, P., Mortensen, P. T., & Nielsen, J. C. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq497 · Cited by 376
Self-citationReynolds, M. R., Cohen, D. J., Kugelmass, A. D., Brown, P. P., Becker, E. R., Culler, S. D., & Simon, A. W. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.02.049 · Cited by 291
Risk Factor Analysis of Permanent Pacemaker Infection
Sohail, M. R., Uslan, D. Z., Khan, A. H., Friedman, P. A., Hayes, D. L., Wilson, W. R., Steckelberg, J. M., Stoner, S. M., & Baddour, L. M. (2007) · Clinical Infectious Diseases · doi:10.1086/518889 · Cited by 288
Evaluation of Early Complications Related to De Novo Cardioverter Defibrillator Implantation
Lee, D. S., Krahn, A. D., Healey, J. S., Birnie, D., Crystal, E., Dorian, P., Simpson, C. S., Khaykin, Y., Cameron, D., Janmohamed, A., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.029 · Cited by 228
Complications arising after implantation of DDD pacemakers: the MOST experience
Ellenbogen, K. A., Hellkamp, A. S., Wilkoff, B. L., Camunãs, J. L., Love, J. C., Hadjis, T. A., Lee, K. L., & Lamas, G. A. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(03)00844-0 · Cited by 210
Research works printed but not linked: 5
- 2006, Journal of the American College of Cardiology, 47, 2493, 10.1016/j.jacc.2006.02.049 · DOI · Paper page
- 2005, Journal of the American College of Cardiology, 46, 1536, 10.1016/j.jacc.2005.04.063 · DOI · Paper page
- 2007, Clinical Infectious Diseases, 45, 166, 10.1086/518889 · DOI · Paper page
- 2011, Circulation: Arrhythmia and Electrophysiology, 4, 136, 10.1161/CIRCEP.110.959791 · DOI · Paper page
- 2011, Circulation: Cardiovascular Quality and Outcomes, 4, 549, 10.1161/CIRCOUTCOMES.110.959205 · DOI
Cited by
Items 501–600 of 871
Sondenloser Schrittmacher Micra™: Klinische Erfahrungen und Perspektiven
Steinwender, C., Blessberger, H., Kiblböck, D., Saleh, K., & Kammler, J. (2018) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-018-0592-9 · Cited by 7
Documentation of shared decision making around primary prevention defibrillator implantations
Barakat, A. F., Asif, A., Inashvili, A., Szeto, L., Noor, A., Thalappillil, A., Adhikari, S., Fatima, S., Pasupula, D. K., Ahmad, S., et al. (2019) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13846 · Cited by 4
Cardiac Resynchronization Therapy Upgrade
Shetty, A., & Rinaldi, C. A. (2017) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.117.004956 · Cited by 4
Scagliola, R. (2020) · The Anatolian Journal of Cardiology · doi:10.14744/anatoljcardiol.2020.57870 · Cited by 4
Left bundle branch area pacing in perspective
Brignole, M., & Sutton, R. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac447 · Cited by 4
Liu, Y., Liu, H., Zhu, B., Li, H., Cui, N., Ye, F., Gao, J., Zhang, X., & Wu, Y. (2025) · Cardiology · doi:10.1159/000549488 · Cited by 3
van der Stuijt, W., Friedman, P. A., Deshmukh, A. J., Daly, M. G., Downey, R. A., Aasbo, J. D., Jurišić, Z., Anić, A., Ebner, A. A., Nordkamp, L. R. A. O., et al. (2025) · Heart Rhythm · doi:10.1016/j.hrthm.2025.10.035 · Cited by 3
Applications of Endovascular Brain–Computer Interface in Patients with Alzheimer’s Disease
Sun, Y., Chen, D., Ye, Q., You, Z., Zhao, Z., Shi, J., Sun, H., Li, S., Xu, X., Xu, Y., et al. (2025) · Research · doi:10.34133/research.1049 · Cited by 5
Carecci, A., Biffi, M., Lazzeri, M., Quaranta, A., Bartoli, L., Spadotto, A., Martignani, C., Angeletti, A., Diemberger, I., Massaro, G., et al. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14248746 · Cited by 3
Lohbihler, M., Lim, A. A., Massé, S., Murareanu, B. M., Kwan, M., Mourad, O., Mastikhina, O., Elbatarny, M., Sarao, R., Qiang, B., et al. (2026) · Cell stem cell · doi:10.1016/j.stem.2026.02.012 · Cited by 4
Adoubi, K. A., Coulibaly, I., N’Djessan, J. J., Gnaba, A., Tano, M., Tro, G., & Kendja, F. (2021) · Annales de Cardiologie et d Angéiologie · doi:10.1016/j.ancard.2021.01.005 · Cited by 5
Biofilm formation: A well-played game in bacterial pathogenesis
Thite, V. S., Bharathi, R. K., & Srinandan, C. S. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-99977-9.00009-0 · Cited by 3
Biffi, M., Statuto, G., Calvi, V. I., Iori, M., Maria, E. D., Bolognesi, M. G., Allocca, G., Notarangelo, F., Carinci, V., Ammendola, E., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.10.004 · Cited by 3
Yan, L., Lin, L., Song, Y., & Jiang, T. (2024) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt-24-181 · Cited by 3
Epstein, L. M., El‐Chami, M. F., Steinwender, C., & Soejima, K. (2025) · European Heart Journal Supplements · doi:10.1093/eurheartjsupp/suae102 · Cited by 4
Lead Perforation in Cardiac Implantable Electronic Devices: Incidence, Diagnosis, and Management
Bolaji, O., Markson, F., Kwaku, K. F., & Schaller, R. D. (2025) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.15210 · Cited by 4
Sensi, F. D., Paneni, F., Addonisio, L., Breschi, M., Miracapillo, G., & Severi, S. (2014) · International Journal of Cardiology · doi:10.1016/j.ijcard.2014.08.014 · Cited by 3
Patients predict their own outcome with CRT
Kronborg, M. B., & Nielsen, J. C. (2015) · Netherlands Heart Journal · doi:10.1007/s12471-015-0776-4 · Cited by 3
Self-citationDiemberger, I., Marazzi, R., Casella, M., Vassanelli, F., Galimberti, P., Luzi, M., Borrelli, A., Soldati, E., Golzio, P. G., Fumagalli, S., et al. (2017) · EP Europace · doi:10.1093/europace/eux034 · Cited by 3
Bolzan, B., Morosato, M., Caponi, D., Tomasi, L., Silvestre, G., & Morani, G. (2018) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1093/icvts/ivy002 · Cited by 3
Verma, B. R., Banerjee, K., Noll, A. E., Ala, C. K., Badar, M., Kwon, D. H., Jellis, C. L., Hachamovitch, R., Hussein, A. A., & Klein, A. L. (2019) · Herz · doi:10.1007/s00059-019-4807-6 · Cited by 3
Complications related to cardiac implantable electronic devices
Vanegas, D. I., Ibatá, L., Franco-Garrido, P. A., & Valderrama-Barbosa, Z. (2019) · Revista Colombiana de Cardiología · doi:10.1016/j.rccar.2019.02.005 · Cited by 5
Mohamed, M., Greenspon, A. J., Contractor, T. A., Rashid, M. O., Kwok, C. S., Potts, J. E., Barker, D., Patwala, A., & Mamas, M. A. (2019) · International Journal of Cardiology · doi:10.1016/j.ijcard.2019.07.095 · Cited by 3
Novikov, A. V., & Serguladze, S. Y. (2019) · Annaly aritmologii · doi:10.15275/annaritmol.2019.4.5 · Cited by 3
Prevention of Infection: Indications, Device Programming, Patient Follow-Up
Biffi, M., Angeletti, A., & Ziacchi, M. (2020) · Springer eBooks · doi:10.1007/978-3-030-46255-0_12 · Cited by 3
Dewidar, O., BIRNIE, D. H., Podinic, I., Welch, V. A., & Wells, G. A. (2021) · Systematic Reviews · doi:10.1186/s13643-021-01746-x · Cited by 5
Ostrowska, B., Gkiouzepas, S., Kurland, S., & Blomström‐Lundqvist, C. (2021) · Clinical Cardiology · doi:10.1002/clc.23620 · Cited by 3
Hames, R. A., Hayanga, J. W. A., Schmidt-Krings, D., Goldhardt, T., Bozek, J. S., Siddoway, D., Schmidt, S. B., Lobban, J. H., & Hayanga, H. K. (2021) · Case Reports in Anesthesiology · doi:10.1155/2021/5559830 · Cited by 3
Neue Entwicklungen bei kabellosen Schrittmachersystemen
Doldi, F., Biller, B., Reinke, F., & Eckardt, L. (2021) · Herz · doi:10.1007/s00059-021-05075-6 · Cited by 3
Frame-rate reduction to reduce radiation dose for cardiac device implantation is safe
Bork, F. T., Boehmer, A. A., Zezyk, C., Kaess, B. M., & Ehrlich, J. R. (2023) · Heart Rhythm O2 · doi:10.1016/j.hroo.2023.05.003 · Cited by 3
Shoukri, N., Barefoot, N. Z., Haines, D. E., Steín, K. M., & Mehta, N. K. (2023) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-023-01580-2 · Cited by 3
The Micra Transcatheter Pacing System: Past, Present and the Future
Toon, L.-T., & Roberts, P. R. (2023) · Future Cardiology · doi:10.2217/fca-2023-0093 · Cited by 4
Cough-induced sudden acute chest pain and massive left hemothorax soon after pacemaker implantation
Martini, N., Migliore, F., Pittorru, R., Rizzo, A., Motta, R., Barbiero, G., & Lazzari, M. D. (2023) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-023-01725-3 · Cited by 3
Modular Cardiac Rhythm Management: Tailoring Nontransvenous Arrhythmic Treatment
Tang, J. E., Guirguis, F., Iyer, M. H., Essandoh, M. K., & Gorelik, L. A. (2024) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2024.09.145 · Cited by 3
Shah, A. S., Engels, M., Freedman, R. A., Lehmann, H. I., Konstantinidis, K., Ranjan, R., & Bunch, T. J. (2025) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.125.013831 · Cited by 3
Ito, N., Kurabayashi, M., Okishige, K., & Hirao, K. (2018) · European Heart Journal - Case Reports · doi:10.1093/ehjcr/yty074 · Cited by 3
Cardiac Stimulation in the Third Millennium: Where Do We Head from Here?
Biffi, M., Spadotto, A., Piemontese, G. P., Toniolo, S., Bartoli, L., Sorrentino, S., Minguzzi, A., Massaro, G., Capobianco, C., & Statuto, G. (2021) · Hearts · doi:10.3390/hearts2010003 · Cited by 3
Senaratne, J. M., Wijesundera, J., Chhetri, U., Beaudette, D., Sander, A., Hanninen, M., Gulamhusein, S. S., & Senaratne, M. (2022) · Medicine · doi:10.1097/md.0000000000030944 · Cited by 3
Mańkowska‐Załuska, B., Chudzik, M., Lobodzinski, S. M., Nowek, A., Urbanek, B., Topolska, E., Oszczygieł, A., Cygankiewicz, I., & Wranicz, J. K. (2015) · Kardiologia Polska · doi:10.5603/kp.a2015.0211 · Cited by 3
Load Modulation For Leadless Pacemaker Synchronization In A Dual Chamber Pacemaker System
Palaksha, D., Rizzo, G., Nocua, R., Lefeuvre, É., & Kansanen, K. (2018) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2018.8626674 · Cited by 3
Yamagata, K., Ishibashi, K., Nakajima, K., Kataoka, N., Kamakura, T., Wada, M., Inoue, Y. Y., Miyamoto, K., Nagase, S., Noda, T., et al. (2019) · Journal of Arrhythmia · doi:10.1002/joa3.12179 · Cited by 3
Ahlert, D., & Mitchell, A. R. J. (2019) · European Heart Journal - Case Reports · doi:10.1093/ehjcr/ytz121 · Cited by 3
Nielsen, K. M., Zwisler, A., Taylor, R. S., Svendsen, J. H., Lindschou, J., Anderson, L., & Berg, S. K. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011828 · Cited by 4
Johar, S., & Luqman, N. (2018) · Future Cardiology · doi:10.2217/fca-2017-0106 · Cited by 4
Device implantation and complications: time to recalibrate our expectations?
Milan, D. J., & Singh, J. P. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht568 · Cited by 3
Longevity of implantable cardioverter-defibrillators: still a long way to go
Johansen, J. B., Nielsen, J. C., & Sandgaard, N. C. F. (2016) · EP Europace · doi:10.1093/europace/euw029 · Cited by 3
Self-citationRadiotherapy in Patients with Pacemakers and Implantable Cardioverter Defibrillators
Zaremba, T. (2015) · VBN Forskningsportal (Aalborg Universitet) · doi:10.5278/vbn.phd.med.00021 · Cited by 3
Preminger, M. W., & Mittal, S. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.06.008 · Cited by 3
Cardiac Device Implantation Complications: A Gap in the Quality of Care?
Wong, J. A., & Devereaux, P. J. (2019) · Annals of Internal Medicine · doi:10.7326/m19-1895 · Cited by 3
ElRefai, M., Menexi, C., Abouelasaad, M., & Roberts, P. R. (2023) · British Journal of Radiology · doi:10.1259/bjr.20220788 · Cited by 2
Kowlgi, G. N., Vaidya, V. R., Dai, M., Futela, P., Mishra, R. K., Hodge, D. O., Deshmukh, A. J., Mulpuru, S. K., Friedman, P. A., & Cha, Y. (2024) · Heart Rhythm O2 · doi:10.1016/j.hroo.2024.02.001 · Cited by 2
Chung, D., Hochadel, M., Senges, J., Kleemann, T., Eckardt, L., Brachmann, J., Steinbeck, G., Larbig, R. K., Butter, C., Uher, T., et al. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13133858 · Cited by 2
Intramural Hematoma and Acute Pulmonary Embolism Following Pacemaker Implantation: A Case Report
Monaco, G. D., Taormina, A., Levra, A. G., Monti, L., & Frontera, A. (2024) · Cureus · doi:10.7759/cureus.65475 · Cited by 3
Pacemaker Indications and Long‐Term Stability of Pacing Indices in Heart Transplant Recipients
Aspe, P. F.-D., Vázquez‐García, R., Used‐Gavín, A., Rodríguez-Garrido, J. L., Mosquera‐Pérez, I., Paniagua-Martín, M. J., Barge‐Caballero, E., Barge‐Caballero, G., Couto‐Mallón, D., Enríquez-Vázquez, D., et al. (2025) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16671 · Cited by 3
Roseboom, E., Daniëls, F., Klingenberg, M. G., Groenveld, H. F., Mulder, B. A., Rienstra, M., & Maass, A. H. (2025) · Heart Rhythm · doi:10.1016/j.hrthm.2025.08.033 · Cited by 2
He, J., Liang, K., Huang, R., Su, C., Zhou, J.-C., Wang, L., & Zhou, J. (2025) · EP Europace · doi:10.1093/europace/euaf268 · Cited by 3
Leadless Devices: the Future of Pacing
Furman, B. W., Wang, B., Sajja, A., & El‐Chami, M. F. (2025) · Current Cardiology Reports · doi:10.1007/s11886-025-02331-7 · Cited by 4
Atrioventricular synchrony maintained by a dual-chamber leadless pacemaker in real-world conditions
Defaye, P., Reddy, V. Y., Ip, J. E., Doshi, R. N., Exner, D. V., Canby, R. C., Bongiorni, M. G., Shoda, M., Hindricks, G., Rashtian, M. Y., et al. (2026) · EP Europace · doi:10.1093/europace/euag012 · Cited by 4
Insights from 10-year follow-up of His bundle pacing: A multicenter experience
Zanon, F., Marcantoni, L., Subzposh, F. A., Deluca, F., Valenza, S., Porcelli, G., Picariello, C., Roccabruna, A., Jannello, E. M. S., Angela, S., et al. (2026) · Heart Rhythm · doi:10.1016/j.hrthm.2026.03.1884 · Cited by 3
Soleimani, H., Razeghian, I., Dastjerdi, P., Mohammadi, N. S. H., Shayesteh, H., Hadadi, C. A., Eslami, M., & Mollazadeh, R. (2026) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.70253 · Cited by 2
Vitkauske, P. V. P., Gutzeit, M., Jaegers, H. J. H., Adomeit, H.-J., Macher-Heidrich, S., Hasan, F., Zarse, M., Bogossian, H., Wiegand, U., Kloppe, A., et al. (2026) · European Heart Journal - Quality of Care and Clinical Outcomes · doi:10.1093/ehjqcco/qcag109 · Cited by 2
Pneumothorax as a complication of cardiac rhythm management devices implantation
Radovanović, N. N., Kirćanski, B., Pavlović, S. U., Raspopović, S., Jovanovic, V., Nikčević, G., Novakovic, A., Živković, M., & Milašinović, G. (2017) · Srpski arhiv za celokupno lekarstvo · doi:10.2298/sarh160712062r · Cited by 2
Farkowski, M. M., Maciąg, A., Ciszewski, J. B., Kowalik, I., Syska, P., Sterlinski, M. M., Szwed, H., & Pytkowski, M. (2019) · Scandinavian Cardiovascular Journal · doi:10.1080/14017431.2019.1653489 · Cited by 2
Futami, M., Komaki, T., Arinaga, T., Morii, J., Sugihara, M., Ogawa, M., & Miura, S.-I. (2019) · Internal Medicine · doi:10.2169/internalmedicine.3729-19 · Cited by 3
Sheath shape pattern during leadless pacemaker implantation
Tachibana, M., Banba, K., Hasui, Y., Matsumoto, K., Ohara, M., Hayashida, A., Kawamoto, T., & Hirohata, A. (2022) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-022-01136-w · Cited by 2
Táborský, M., Kautzner, J., Fedorco, M., Čurila, K., Wünschová, H., Pyszko, J., Novák, M., Kozák, M., Válek, M., Polášek, R., et al. (2022) · Cor et Vasa · doi:10.33678/cor.2022.024 · Cited by 4
Omura, A., Onuki, T., Mase, H., Kurata, M., Wakatsuki, D., & Suzuki, H. (2022) · HeartRhythm Case Reports · doi:10.1016/j.hrcr.2022.05.025 · Cited by 2
Zhang, J., Chen, C., Xing, Q., Zhou, X., Li, Y., Zhang, L., Lu, Y., Tu-Erhong, Z. K., Yang, X., Liu, X., et al. (2022) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-022-02686-w · Cited by 3
NL-EVDR: Netherlands—ExtraVascular Device Registry
Tjong, F. V. Y., Breeman, K. T. N., Boersma, L. V. A., Yap, S., van Erven, L., van der Stoel, M. D., van Dijk, V. F., Maass, A. H., & Knops, R. E. (2023) · Netherlands Heart Journal · doi:10.1007/s12471-023-01768-1 · Cited by 3
Kawada, S., Nishii, N., Mizuno, T., Miyamoto, M., Nakagawa, K., & Morita, H. (2023) · HeartRhythm Case Reports · doi:10.1016/j.hrcr.2023.09.009 · Cited by 2
The 1st implantation of an atrial only leadless pacemaker in right atrial appendage
Sundaram, S., Alyesh, D. M., Walker, L., & Zipse, M. M. (2023) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-023-01644-3 · Cited by 2
Chabrak, S., Haggui, A., Allouche, E., Ouali, S., Halima, A. B., Kacem, S., Krichen, S., Marrakchi, S., Fehri, W., Mourali, M. S., et al. (2023) · JMIR Research Protocols · doi:10.2196/47525 · Cited by 2
Alves, L. B. D. O., da Silva, K. R., de Barros, J. V., Colugnati, F. A. B., Filho, M. M., & Costa, R. (2024) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20230386 · Cited by 5
Therapie mit kardialen elektronischen implantierbaren Devices
Kuschyk, J., Sattler, K., Fastenrath, F., Rudic, B., & Akın, İ. (2024) · Herz · doi:10.1007/s00059-024-05246-1 · Cited by 2
Mitacchione, G., Curnis, A., Celentano, E., Rovaris, G., Battista, A., Marini, M., Bella, P. E. D., Santobuono, V. E., Biffi, M., Tomasi, L., et al. (2025) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16666 · Cited by 2
Tijskens, M., Schouwer, K. D., Wolf, M., Greef, Y. D., & Schwagten, B. (2025) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.70014 · Cited by 2
Conduction system pacing for pacing-induced cardiomyopathy: Could the cure be worse than the ill?
Lau, E. W., Bonnemeier, H., & Baldauf, B. J. (2025) · Heart Rhythm · doi:10.1016/j.hrthm.2025.06.017 · Cited by 3
Leadless Pacemakers: A Contemporary Review
Ahmad, A., & Doshi, R. N. (2025) · Current Cardiovascular Risk Reports · doi:10.1007/s12170-025-00773-w · Cited by 2
Leadless Pacemaker Technologies: Patient Selection, Approach, and Outcomes
Koene, R. J., & Cantillon, D. J. (2018) · Current Cardiovascular Risk Reports · doi:10.1007/s12170-018-0575-8 · Cited by 2
Hu, Y., & Hua, W. (2019) · 中国科学通报:英文版 · doi:10.1016/j.scib.2019.05.010 · Cited by 2
Looi, K., Lever, N. A., Gavin, A., & Doughty, R. N. (2019) · BMJ Open · doi:10.1136/bmjopen-2018-025634 · Cited by 2
Selección de lo mejor del año 2020 en estimulación cardiaca
Andrés, M. L. F., Pérez, Ó. C., Jiménez, M. P., García, J. C., Bertomeu‐González, V., & Carreño, D. L. (2021) · REC CardioClinics · doi:10.1016/j.rccl.2020.10.014 · Cited by 2
Raja, J. M., Guice, K. C., Oberoi, M., Whitwell, S. A., Asbeutah, A. A., Russell, A., & Khouzam, R. N. (2021) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2021.100927 · Cited by 2
A leadless pacemaker matched with a vasovagal syncope: how long can it last?
ElRefai, M., Menexi, C., Abouelasaad, M., Nettey, D., & Roberts, P. R. (2022) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14546 · Cited by 4
Rizkallah, J., Kent, W. D. T., Kuriachan, V. P., Burgess, J., & Exner, D. V. (2015) · BMC Research Notes · doi:10.1186/s13104-015-1034-y · Cited by 2
Knops, R. E., & Brouwer, T. F. (2016) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2016.09.030 · Cited by 2
Knops, R. E., & Brouwer, T. F. (2017) · Revista Española de Cardiología · doi:10.1016/j.recesp.2016.09.041 · Cited by 2
Subcutaneous Implantable Cardioverter Defibrillators
Grace, A. A., & Bardy, G. H. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-44733-1.00118-8 · Cited by 2
Johar, S., & Luqman, N. (2018) · BMJ Case Reports · doi:10.1136/bcr-2017-222471 · Cited by 2
Cortés, M., Palfy, J. A., López, M., Martinez, J., Rivero, A. L., Devesa, A., Peláez, J. A. F., Figuero, S. B., Urquía, M. T., Bénézet, J. M., et al. (2018) · ESC Heart Failure · doi:10.1002/ehf2.12310 · Cited by 2
Feasibility Analysis for Pulse-Based Synchronization in a Dual Chamber Leadless Pacemaker System
Palaksha, D., Kansanen, K., & Awan, M. F. (2020) · EAI/Springer Innovations in Communication and Computing · doi:10.1007/978-3-030-29897-5_37 · Cited by 2
From leads to leadless: A convoluted journey
Dulam, V., Cooper, J. M., Gangireddy, C., Kashem, M. A., Toyoda, Y., & Keshavamurthy, S. (2020) · HeartRhythm Case Reports · doi:10.1016/j.hrcr.2020.07.010 · Cited by 2
Pseudoaneurisma de arteria mamaria tras implantación de marcapasos
García, N., Estévez, C., del Pozo, M., Santillana, M., Muñoz, R., & Calleja, F. (2021) · Cirugía Cardiovascular · doi:10.1016/j.circv.2020.12.002 · Cited by 2
Lee, H. M., Park, J. W., Na, Y. C., Yoon, C. S., Kim, J. H., & Kim, N. (2022) · Journal of Wound Management and Research · doi:10.22467/jwmr.2021.01865 · Cited by 2
Rathi, A., Kanee, L., Limoges, M., Connelly, K. A., Jiménez‐Juan, L., Kirpalani, A., Angaran, P., Pintér, A., Yan, A. T.-K., & Deva, D. P. (2022) · Journal of Thoracic Imaging · doi:10.1097/rti.0000000000000652 · Cited by 2
Pagore, P. A., & Gaidhane, S. (2022) · Cureus · doi:10.7759/cureus.30170 · Cited by 3
Rios, L. H. P., Minga, I., Gaznabi, S., Erwin, J. P., Tafur, A. J., & Metzl, M. D. (2022) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-022-01423-6 · Cited by 3
Лебедева, Н. Б., Talibullin, I. V., Геннадьевич, П. П., Mamchur, S. E., & Барбараш, О. Л. (2023) · Complex Issues of Cardiovascular Diseases · doi:10.17802/2306-1278-2022-11-4-139-150 · Cited by 2
Benbuk, A. A., Gulick, D. W., Garcia, D. P. M., Liu, S., Quiñones‐Hinojosa, A., & Christen, J. B. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3329447 · Cited by 2
Wei, Z., Wang, H., Li, D., Vai, M. I., Pun, S. H., Yang, J., Du, M., & Gao, Y. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3360997 · Cited by 3
Metadata
- Authors
- Kirkfeldt, R. E., Johansen, J. B., Nohr, E. A., Jorgensen, O. D., & Nielsen, J. C.
- Affiliations
- Odense University Hospital (DK)
- Aarhus University (DK)
- Aarhus University Hospital (DK)
- Corresponding author
- Kirkfeldt, R. E.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-12-17
- Volume
- 35
- Issue
- 18
- Pages
- 1186-1194
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- PMC
- PMC4012708
- OpenAlex
- W2109817867
- Cited by
- 871
- References
- 33
- Citations by year
- 2026: 68 · 2025: 73 · 2024: 68 · 2023: 84 · 2022: 94 · 2021: 66 · 2020: 71 · 2019: 68 · 2018: 92 · 2017: 74 · 2016: 46 · 2015: 50 · 2014: 16 · 2013: 1
- FWCI
- 25.63
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc
- Locations
- European Heart Journal (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- University of Southern Denmark Research Portal (University of Southern Denmark) (submittedVersion)
- Funders
- Hjerteforeningen
- Aarhus Universitet
- Aalborg Universitet
- Odense Universitetshospital
- Rigshospitalet
- Aalborg Universitetshospital
- Gangstedfonden
- Region Midtjylland
- Bispebjerg Hospital
- St. Jude Medical
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Emergency Medicine › Cardiac Arrest and Resuscitation
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Infective Endocarditis Diagnosis and Management
- Keywords
- cardiac implantable electronic devices, post-implantation complications, permanent pacemaker, cardiac resynchronization therapy, CRT-D, implantable cardioverter-defibrillator, dual-chamber ICD, lead revision, system upgrade, operator volume, hospital volume, risk factors
- MeSH terms
- Adolescent, Adult, Aged, Aged, 80 and over, Child, Child, Preschool, Denmark, Female, Humans, Infant, Infant, Newborn, Male, Middle Aged, Pacemaker, Artificial, Postoperative Complications, Prosthesis Failure, Risk Factors, Cohort Studies, Defibrillators, Implantable, Age Distribution, Sex Distribution, Device Removal, Young Adult, Cardiac Resynchronization Therapy Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.