Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
AIMS: Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient morbidity, healthcare costs, and possibly increased mortality. METHODS AND RESULTS: Population-based cohort study in all Danish patients who underwent a CIED procedure from May 2010 to April 2011. Data on complications were gathered on review of all patient charts while baseline data were obtained from the Danish Pacemaker and ICD Register. Adjusted risk ratios (aRRs) with 95% confidence intervals were estimated using binary regression. The study population consisted of 5918 consecutive patients. A total of 562 patients (9.5%) experienced at least one complication. The risk of any complication was higher if the patient was a female (aRR 1.3; 1.1-1.6), underweight (aRR 1.5; 1.1-2.3), implanted in a centre with an annual volume <750 procedures (0-249 procedures: aRR 1.6; 1.1-2.2, 250-499: aRR 2.0; 1.6-2.7, 500-749: aRR 1.5; 1.2-1.8), received a dual-chamber ICD (aRR 2.0; 1.4-2.7) or CRT-D (aRR 2.6; 1.9-3.4), underwent system upgrade or lead revision (aRR 1.3; 1.0-1.7), had an operator with an annual volume <50 procedures (aRR 1.9; 1.4-2.6), or underwent an emergency, out-of-hours procedure (aRR 1.5; 1.0-2.3). CONCLUSION: CIED complications are more frequent than generally acknowledged. Both patient- and procedure-related predictors may identify patients with a particularly high risk of complications. This information should be taken into account both in individual patient treatment and in the planning of future organization of CIED treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Despite great advancements in implantable cardiac pacemaker technology, complications from pacemaker leads continue to compromise nearly 10% of all implants1, 2.”
From Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system (2017) · cites this paper as [1]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · PubMed · Cited by 13,173
Obesity : Preventing and managing the global epidemic
Akram, D. S., Astrup, A. V., Atinmo, T., Boissin, J.-L., Bray, G. A., Carroll, K. N., Chitson, P., Chen, C., Dietz, W. H., Hill, J. O., et al. (2000) · Research at the University of Copenhagen (University of Copenhagen) · Cited by 12,945
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht150 · Cited by 2,809
Self-citationPoole, J. E., Gleva, M. J., Mela, T., Chung, M. K., Uslan, D. Z., Borge, R., Gottipaty, V., Shinn, T., Dan, D., Feldman, L. A., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.976076 · Cited by 790
Udo, E. O., Zuithoff, N. P. A., van Hemel, N. M., de Cock, C. C., Hendriks, T., Doevendans, P. A., & Moons, K. G. M. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.014 · Cited by 597
Johansen, J. B., Jorgensen, O. D., Moller, M., Arnsbo, P., Mortensen, P. T., & Nielsen, J. C. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq497 · Cited by 376
Self-citationReynolds, M. R., Cohen, D. J., Kugelmass, A. D., Brown, P. P., Becker, E. R., Culler, S. D., & Simon, A. W. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.02.049 · Cited by 291
Risk Factor Analysis of Permanent Pacemaker Infection
Sohail, M. R., Uslan, D. Z., Khan, A. H., Friedman, P. A., Hayes, D. L., Wilson, W. R., Steckelberg, J. M., Stoner, S. M., & Baddour, L. M. (2007) · Clinical Infectious Diseases · doi:10.1086/518889 · Cited by 288
Evaluation of Early Complications Related to De Novo Cardioverter Defibrillator Implantation
Lee, D. S., Krahn, A. D., Healey, J. S., Birnie, D., Crystal, E., Dorian, P., Simpson, C. S., Khaykin, Y., Cameron, D., Janmohamed, A., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.029 · Cited by 228
Complications arising after implantation of DDD pacemakers: the MOST experience
Ellenbogen, K. A., Hellkamp, A. S., Wilkoff, B. L., Camunãs, J. L., Love, J. C., Hadjis, T. A., Lee, K. L., & Lamas, G. A. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(03)00844-0 · Cited by 210
Research works printed but not linked: 5
- 2006, Journal of the American College of Cardiology, 47, 2493, 10.1016/j.jacc.2006.02.049 · DOI · Paper page
- 2005, Journal of the American College of Cardiology, 46, 1536, 10.1016/j.jacc.2005.04.063 · DOI · Paper page
- 2007, Clinical Infectious Diseases, 45, 166, 10.1086/518889 · DOI · Paper page
- 2011, Circulation: Arrhythmia and Electrophysiology, 4, 136, 10.1161/CIRCEP.110.959791 · DOI · Paper page
- 2011, Circulation: Cardiovascular Quality and Outcomes, 4, 549, 10.1161/CIRCOUTCOMES.110.959205 · DOI
Cited by
Items 401–500 of 871
López‐Gil, M., Fontenla, A., Calvo, J. J. C. J., Parra, J. O. H., & Arribas, F. (2016) · EP Europace · doi:10.1093/europace/euv423 · Cited by 7
An Update on Cardiac Implantable Electronic Devices for the General Physician
Peal, J., Matthews, I., Runnett, C., Thomas, H. E., & Ripley, D. P. (2018) · The Journal of the Royal College of Physicians of Edinburgh · doi:10.4997/jrcpe.2018.208 · Cited by 8
Fyenbo, D. B., Sommer, A., Kühl, J. T., Kofoed, K. F., Nørgaard, B. L., Kronborg, M. B., Bouchelouche, K., & Nielsen, J. C. (2018) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0000000000000824 · Cited by 7
Self-citationThe year in cardiology 2014: arrhythmias and device therapy
Heidbüchel, H., & Hindricks, G. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehu486 · Cited by 10
Caiati, C., Pollice, P., Truncellito, L., Lepera, M. E., & Favale, S. (2020) · Diagnostics · doi:10.3390/diagnostics10040191 · Cited by 7
A Multi-Dimensional Analysis of a Novel Approach for Wireless Stimulation
Abiri, P., Yousefi, A., Abiri, A., Gudapati, V., Ding, Y., Nguyen, K., Abiri, A., Markovic, D. M., Tai, Y., & Hsiai, T. K. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2983443 · Cited by 8
Søholm, H., Laursen, M. L., Kjærgaard, J., Lindhardt, T. B., Hassager, C., Møller, J. E., Gregers, E., Linde, L., Johansen, J. B., Winther‐Jensen, M., et al. (2021) · Scandinavian Cardiovascular Journal · doi:10.1080/14017431.2021.1900597 · Cited by 9
Self-citationEmerging Technologies in Electrophysiology: From Single-Chamber to Biventricular Leadless Pacemakers
Gill, J. (2022) · Cardiology · doi:10.1159/000521976 · Cited by 7
ElRefai, M., Abouelasaad, M., Menexi, C., Morgan, J. M., & Roberts, P. R. (2022) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-022-01218-9 · Cited by 8
Cardiac imaging for the prediction of sudden cardiac arrest in patients with heart failure
Lio, F. D., Andreis, A., LIO, G. D., Bellettini, M., Pidello, S., Raineri, C., Gallone, G., Alunni, G., Frea, S., Imazio, M., et al. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e17710 · Cited by 6
Sultan, A., Scheurlen, C., Wörmann, J., van den Bruck, J., Filipovic, K., Erlhöfer, S., Dittrich, S., Schipper, J., Lüker, J., Sinning, J., et al. (2023) · Clinical Research in Cardiology · doi:10.1007/s00392-023-02286-1 · Cited by 10
Pacemaker replacement in nonagenarians: Procedural safety and long-term follow-up
Loirat, A., Fénéon, D., Behaghel, A., Béhar, N., Helloco, A. L., Mabo, P., Daubert, J., Leclercq, C., & Martins, R. P. (2015) · Archives of cardiovascular diseases · doi:10.1016/j.acvd.2015.01.014 · Cited by 8
Why We Have to Use Cardiac Resynchronization Therapy–Pacemaker More
Daubert, J., Martins, R. P., & Leclercq, C. (2015) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2015.08.016 · Cited by 7
Lead or be led: an update on leadless cardiac devices for general physicians
Wiles, B. M., & Roberts, P. R. (2017) · Clinical Medicine · doi:10.7861/clinmedicine.17-1-33 · Cited by 7
Tonegawa‐Kuji, R., Inoue, Y. Y., Nakai, M., Kanaoka, K., Sumita, Y., Miyazaki, Y., Wakamiya, A., Shimamoto, K., Ueda, N., Wada, M., et al. (2022) · Heart Rhythm · doi:10.1016/j.hrthm.2022.02.006 · Cited by 8
Long-Term Implications of Pacemaker Insertion in Younger Adults: A Single Centre Experience
Shirwaiker, A., William, J., Mariani, J. A., Kistler, P. M., Patel, H. C., & Voskoboinik, A. (2022) · Heart Lung and Circulation · doi:10.1016/j.hlc.2022.01.009 · Cited by 7
Cardiac implantable electronic device infection: more risks, more effort for its prevention?
Bongiorni, M. G., & Zucchelli, G. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz407 · Cited by 7
Advances in cardiac pacing with leadless pacemakers and conduction system pacing
Somani, S. S., & Rogers, A. J. (2023) · Current Opinion in Cardiology · doi:10.1097/hco.0000000000001092 · Cited by 5
Bilal, M., Syed, N. N., Jamil, Y., Tariq, A., & Khan, H. R. (2024) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14955 · Cited by 6
Heart failure, sudden cardiac death and implantable cardioverter-defibrillators: sex matters
Čulić, V., & AlTurki, A. (2024) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000001660 · Cited by 6
Doshi, S. K., Knops, R. E., Ebner, A. A., Husby, M. P., Marcovecchio, A., Sanghera, R., Scheck, D. E., & Burke, M. C. (2025) · EP Europace · doi:10.1093/europace/euaf044 · Cited by 6
Evaluation of sudden cardiac death in hypertrophic cardiomyopathy
Yoon, S. G., & Hong, G. (2025) · Journal of Cardiovascular Imaging · doi:10.1186/s44348-025-00054-5 · Cited by 7
Baumgartner, T., Kaelin-Friedrich, M., Makowski, K., Noti, F., Schaer, B. A., Haeberlin, A., Badertscher, P., Kozhuharov, N., Baldinger, S. H., Seiler, J., et al. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11164927 · Cited by 6
Maass, A. H., Tuinenburg, A. E., Mairuhu, G., Faes, M. C., Klinkenberg, T. J., Ruigrok, S., Koster, M., Stegeman, B. H., & LUERMANS, J. G. L. M. (2025) · Netherlands Heart Journal · doi:10.1007/s12471-024-01927-y · Cited by 8
Leadless cardiac pacing: What primary care providers and non-EP cardiologists should know
Kiehl, E. L., & Cantillon, D. J. (2016) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.83.s2.04 · Cited by 6
Leadless Pacemakers: practice and promise in congenital heart disease
Clarke, T., Zaidi, A. M., & Clarke, B. (2017) · Journal of Congenital Cardiology · doi:10.1186/s40949-017-0007-5 · Cited by 7
Complications associated with cardiac resynchronization therapy upgrades versusde novoimplantations
Sidhu, B. S., Gould, J., Sieniewicz, B., Porter, B., & Rinaldi, C. A. (2018) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2018.1498783 · Cited by 6
Oosterwerff, E. F. J., Adiyaman, A., Elvan, A., Ghani, A., Hoek, L., Breeman, K. T. N., Smit, J. J. J., Misier, A. R. R., & Delnoy, P. P. H. M. (2021) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14364 · Cited by 6
Passos, L. C. S., Viana, T. T., Carvalho, W., Grimaldi, A., Roriz, P. D. S., Figueiredo, C. S., do Nascimento, T. A., & de Melo, R. M. V. (2021) · ESC Heart Failure · doi:10.1002/ehf2.13611 · Cited by 6
Frausing, M. H. J. P., Nielsen, J. C., Johansen, J. B., Jørgensen, O. D., Olsen, T., Kristensen, J., Gerdes, C., & Kronborg, M. B. (2022) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-022-01236-7 · Cited by 6
Self-citationMishkina, A. I., Саушкин, В. В., Atabekov, T. A., Sazonova, S. I., Shipulin, V. V., Massalha, S., Batalov, R. E., Popov, S. V., & Zavadovsky, K. V. (2022) · Journal of Nuclear Cardiology · doi:10.1007/s12350-022-03046-w · Cited by 6
Effect of low body mass index in outcome of Micra leadless pacemaker implantation
Tam, T. K., Chan, A. K.-Y., Au, A. C. K., CHEUNG, L., Chan, G. C. P., & Chan, J. Y. (2022) · Journal of the Hong Kong College of Cardiology · doi:10.55503/2790-6744.1213 · Cited by 7
A First-in-Human Complete Insertion of Single-Chamber Cardiac Pacemaker Using Ultrasound
Khan, H. R. (2022) · JACC Case Reports · doi:10.1016/j.jaccas.2022.05.034 · Cited by 6
Opportunities and drawbacks of the subcutaneous defibrillator across different clinical settings
Russo, V., Ciabatti, M., Brunacci, M., Dendramis, G., Santobuono, V. E., Tola, G., Picciolo, G., Lucciola, M. T., D’Andrea, A., & Nesti, M. (2023) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2023.2184350 · Cited by 6
Patel, H. C., Hayward, C., Nanayakkara, S., Broughton, A., & Mariani, J. A. (2017) · Heart Asia · doi:10.1136/heartasia-2017-010881 · Cited by 6
Complications of Heart Rhythm Management Devices After Cardiac Rehabilitation Program
Rakhshan, M., Ansari, L., Molazem, Z., & Zare, N. (2017) · Clinical Nurse Specialist · doi:10.1097/nur.0000000000000293 · Cited by 6
Koh, Y., Bingham, N. E., Law, N., Le, D., & Mariani, J. A. (2017) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13106 · Cited by 6
Evans, J. M., Cleves, A., Morgan, H. E., Millar, L., & Carolan‐Rees, G. (2017) · Applied Health Economics and Health Policy · doi:10.1007/s40258-017-0354-6 · Cited by 6
2017 ACC/HRS lifelong learning statement for clinical cardiac electrophysiology specialists
Tracy, C. M., Crossley, G. H., Bunch, T. J., Chow, G. V., Leiserowitz, A., Indik, J. H., Kusumoto, F. M., Mendes, L. A., Munger, T. M., Murali, S., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.11.019 · Cited by 6
Why We Have to Use Cardiac Resynchronization Therapy–Pacemaker More
Daubert, J., Martins, R. P., & Leclercq, C. (2016) · Heart Failure Clinics · doi:10.1016/j.hfc.2016.07.012 · Cited by 6
Evolution of extravascular implantable defibrillator technologies
Pfenniger, A., & Knight, B. P. (2019) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2019.04.003 · Cited by 6
Leadless pacemakers – The path to safer pacing?
Nadarajah, R., Ali, N., & Patel, P. A. (2019) · Indian Heart Journal · doi:10.1016/j.ihj.2019.11.255 · Cited by 7
Micra trans-catheter leadless pacemaker implantation in a patient with large right heart
Imamura, T., Koi, T., Kataoka, N., Tanaka, S., Ueno, H., & Kinugawa, K. (2021) · Journal of Cardiology Cases · doi:10.1016/j.jccase.2021.02.015 · Cited by 6
Eccleston, D. S., Cehic, D., Young, G. D., Lin, T., Pavia, S., Chowdhury, E., Reid, C. M., Liew, D., King, B., Tan, I., et al. (2021) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2021.100828 · Cited by 6
Coşgun, M. S., & Cosgun, C. (2022) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14465 · Cited by 6
Khanra, D., Hamid, A., Patel, P. A., Tomson, J., Abdalla, A. A., Khan, N., Dowd, R. P., Chandan, N., Osagie, C. O., Jinadu, T., et al. (2022) · Journal of Arrhythmia · doi:10.1002/joa3.12687 · Cited by 5
Bridging the future of cardiac stimulation: physiologic or leadless pacing?
Piemontese, G. P., Toniolo, S., Biffi, M., Capobianco, C., Bartoli, L., Sorrentino, S., Minguzzi, A., Angeletti, A., Statuto, G., Ziacchi, M., et al. (2022) · Reviews in Cardiovascular Medicine · doi:10.31083/j.rcm2303107 · Cited by 7
Baczkó, I., Leprán, I., Kiss, L., Muntean, D. M., & Light, P. E. (2014) · Current Pharmaceutical Design · doi:10.2174/1381612820666141029101305 · Cited by 7
Long-Term Prognosis of Patients with an Implantable Cardioverter-Defibrillator in Korea
Uhm, J., Kim, T., Kim, I., Park, Y.-A., Shin, D. G., Lim, Y.-M., Yu, H.-T., Yang, P., Pak, H., Kang, S., et al. (2017) · Yonsei Medical Journal · doi:10.3349/ymj.2017.58.3.514 · Cited by 6
Markewitz, A. (2017) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-016-0481-z · Cited by 6
Jordán-Martínez, L., Rivera-López, R., Bermúdez-Jiménez, F., Jiménez-Jaimez, J., Alzueta, J., Barrera-Cordero, A., Rivera-Fernández, R., Jiménez-Navarro, M., Álvarez, M., & Tercedor, L. (2020) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2019.09.028 · Cited by 6
Tong, F., & Sun, Z. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12072454 · Cited by 6
Outcomes of leadless pacemaker implantation in the United States based on sex
Khan, M. Z., Alyami, B., Alruwaili, W., Nguyen, A., Mendez, M., Leon, W., Devera, J., Hayat, H. M. S., Naveed, A., Asad, Z. U. A., et al. (2024) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-024-01936-2 · Cited by 5
New Horizons in Nontransvenous Arrhythmia Management: Aurora Extravascular ICD
Tang, J. E., Dodge, R. E., Guirguis, F., Kumar, N., Arango, S., Holloway, J. O., Wernke, C., Gorelik, L. A., Dimitrova, G. T., Savona, S. J., et al. (2025) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2025.01.029 · Cited by 5
Cardioneuroablation: a new treatment for vasovagal syncope
Saglietto, A., Falasconi, G., Penela, D., Francia, P., Viveros, D., Berruezo, A., Russo, V., Brignole, M., Aksu, T., Anselmino, M., et al. (2025) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000001703 · Cited by 4
Palmisano, P., Rovaris, G., Rocca, D. G. D., Bella, P. E. D., Pisanò, E., Mazzocchetti, L., Palamà, Z., Dell’Era, G., Strangio, A., Russo, A. D., et al. (2025) · Heart Rhythm · doi:10.1016/j.hrthm.2025.03.1881 · Cited by 5
Ou, W., Liu, P., Zhao, N., Dong, A., Chen, S., Wang, G., Wu, S., & Yang, X. (2025) · Journal of the American Heart Association · doi:10.1161/jaha.124.039522 · Cited by 5
Zhang, J., Zhou, X., Lu, Y., Li, Y., Xing, Q., Tuerhong, Z., Xu, Y., Xiaokereti, J., Guo, Y., Zhou, X., et al. (2025) · Clinical Cardiology · doi:10.1002/clc.70209 · Cited by 5
Kerkouri, F., Marquié, C., Bovéda, S., Anselme, F., Anys, S., Badenco, N., Bessière, F., Blangy, H., Bordachar, P., Champ-Rigot, L., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf918 · Cited by 5
Trends in cardiac implantable electronic device infections: 2015 to 2019
Baldauf, B. J., Bode, K., Lau, E. W., Giaccardi, M., Assadian, O., Chevalier, P., Haddad, C., Klöss, A., Cemin, R., Vonthein, R., et al. (2026) · BMC Cardiovascular Disorders · doi:10.1186/s12872-026-06124-w · Cited by 5
Oosterwerff, E. F. J., Theuns, D. A. M. J., Maass, A. H., & van Erven, L. (2024) · Heart Rhythm O2 · doi:10.1016/j.hroo.2024.07.010 · Cited by 5
Risk of Collateral Lead Damage in Percutaneous Cardiac Implantable Electronic Device Extraction
Khan, F., Sverin, G., Birgersdotter-Green, U. M., Miller, J. P., Lalani, G., Pollema, T. L., & Pretorius, V. G. (2017) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2017.07.012 · Cited by 5
Safety and Efficacy of Leadless Pacemakers: A New Era of Pacing
Ammari, Z. A., Syed, M. A., Al‐Sarie, M., Karim, S., & Grubb, B. P. (2018) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2018.090701 · Cited by 5
A Meta-analysis of Major Complications between Traditional Pacemakers and Leadless Pacemakers
Cui, D., Chen, X., Wang, L., Liao, Y., He, H., & Chen, Y. (2020) · Cardiovascular Innovations and Applications · doi:10.15212/cvia.2019.0596 · Cited by 5
Hartrampf, B., Jochheim, D., Steffen, J., Czermak, T., Sadoni, S., Lemmermöhle, E., Klier, I., Estner, H., Maßberg, S., Mehilli, J., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-03667-0 · Cited by 5
Bertolino, L., Florio, L. L., Patauner, F., Gallo, R., Peluso, A. M., Scafuri, A., Vivo, S. D., Corrado, C., Zampino, R., Ruocco, G., et al. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12247573 · Cited by 5
Shawon, M. S. R., Sotade, O. T., Li, J., Hill, M., Strachan, L., Challis, G., King, K., Ooi, S., & Jorm, L. R. (2024) · The Medical Journal of Australia · doi:10.5694/mja2.52302 · Cited by 7
Juarez-Casso, F. M., Schaff, H. V., Todd, A. W., Arghami, A., Rowse, P. G., Dearani, J. A., Daly, R. C., Saran, N., & Crestanello, J. A. (2024) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2024.05.018 · Cited by 5
Procedural safety and long‐term follow‐up after pacemaker implantation in nonagenarians
Dang, D., Galand, V., Loirat, A., Auffret, V., Béhar, N., Mabo, P., Daubert, J., Leclercq, C., & Martins, R. P. (2018) · Clinical Cardiology · doi:10.1002/clc.23083 · Cited by 6
Guan, F., Peng, J., Hou, S., Ren, L., Yue, Y., & Li, G. (2021) · Medicine · doi:10.1097/md.0000000000027837 · Cited by 7
Lo, S., & Chen, J. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.938735 · Cited by 7
Şimşek, E. Ç., Güvendi, E., Şimşek, A., Kocabaş, U., Varış, E., Gürbüz, D. Ç., & Aşkın, A. (2019) · Journal of Arrhythmia · doi:10.1002/joa3.12156 · Cited by 5
Wakatsuki, D., Asano, T., Mase, H., Kurata, M., & Suzuki, H. (2020) · Journal of Cardiology Cases · doi:10.1016/j.jccase.2019.12.002 · Cited by 5
Management of device-related malignant sarcoma
Khamooshian, A., Klinkenberg, T. J., Maass, A. H., & Mariani, M. A. (2017) · HeartRhythm Case Reports · doi:10.1016/j.hrcr.2017.04.002 · Cited by 5
Conventional pacing system: It cannot be done better, it can only change
Tsiachris, D., & Tousoulis, D. (2016) · Hellenic Journal of Cardiology · doi:10.1016/j.hjc.2016.04.003 · Cited by 5
Sex differences in long‐term outcomes following transvenous lead extraction
Arabia, G., Aboelhassan, M., Calvi, E., Cerini, M., Bellicini, M. G., Bontempi, L., Giacopelli, D., Nawar, A., Raweh, A., Abbas, M. M. M., et al. (2024) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16379 · Cited by 4
Biffi, M., Rovaris, G., Pisanò, E., Calvi, Rapacciuolo, A., Santamaria, M., Maglia, G., Zanotto, G., Bertaglia, E., Nigro, G., et al. (2026) · Circulation · doi:10.1161/circulationaha.126.079859 · Cited by 4
Li, S., Shao-Hua, D. O. N. G., Kan, T., Sun, Y., Li, B., Yang, L., Li, P., & Guo, Z. (2023) · 老年心脏病学杂志:英文版 · doi:10.26599/1671-5411.2023.10.006 · Cited by 4
Single-chamber pacemakers: with or without leads? Cost-effectiveness and cost-utility analyses
Lago-Quinteiro, J. R., Reyes-Santías, F., Antelo, M., Caballer-Tarazona, V., Martínez‐Sande, J. L., García‐Seara, J., Rodríguez‐Mañero, M., & González‐Juanatey, J. R. (2025) · Annals of Medicine · doi:10.1080/07853890.2025.2512108 · Cited by 5
Nursing Management for Patients Postoperative Cardiac Implantable Electronic Device Placement
Fowler, L. H. (2018) · Critical Care Nursing Clinics of North America · doi:10.1016/j.cnc.2018.11.007 · Cited by 5
Cosgun, C., Coşgun, M. S., Büyükturan, Ö., & Büyükturan, B. (2023) · PLoS ONE · doi:10.1371/journal.pone.0284178 · Cited by 4
Yuecel, G., Stoesslein, K., Gaasch, L., Kodeih, A., Oeztuerk, O. N., Hetjens, S., Yazdani, B., Pfleger, S., Liebe, V., Rudic, B., et al. (2023) · Acta cardiologica. Supplementum · doi:10.1080/00015385.2023.2277624 · Cited by 5
A Wireless Battery-Free Implant With Optical Telemetry for In Vivo Cortical Stimulation
Benbuk, A. A., Garcia, D. P. M., Gulick, D. W., Quiñones‐Hinojosa, A., & Christen, J. B. (2024) · IEEE Sensors Letters · doi:10.1109/lsens.2024.3387370 · Cited by 5
Kiblboeck, D., Blessberger, H., Ebner, J., Boetscher, J., Maier, J., Reiter, C., Kellermair, J., Steinwender, C., & Saleh, K. (2024) · Clinical Research in Cardiology · doi:10.1007/s00392-024-02516-0 · Cited by 4
Leadless pacing systems: A valuable alternative for patients with severe access problems
Sideris, S. K., Archontakis, S., Vaina, S., Stroumpouli, E., Koumallos, N., Gatzoulis, K. A., Trachanas, K., Leontsinis, I., Sfendouraki, E., Sotiropoulos, I., et al. (2017) · Hellenic Journal of Cardiology · doi:10.1016/j.hjc.2017.11.001 · Cited by 4
Anesthetic Management of a Patient With a Leadless Pacemaker Undergoing Cardiac Surgery
Reddy, S., Coletta, J. M., & Mizuguchi, K. A. (2018) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2018.05.034 · Cited by 4
Bürger, H., Schmitt, J., Knaut, M., Eitz, T., Starck, C. T., Hakmi, S., Siebel, A., & Böning, A. (2018) · Zeitschrift für Herz- Thorax- und Gefäßchirurgie · doi:10.1007/s00398-018-0246-6 · Cited by 6
Salvage of Exposed Cardiac Implants Using Fasciocutaneous Rotation Flaps
Dağdelen, D., & Aksoy, A. (2019) · Annals of Plastic Surgery · doi:10.1097/sap.0000000000001985 · Cited by 5
Mohamed, M., Greenspon, A. J., Spall, H. G. C. V., Volgman, A. S., Sharma, P. S., Alraies, M. C., Kwok, C. S., Martin, G. P., Zachariah, D., Patwala, A., et al. (2019) · International Journal of Cardiology · doi:10.1016/j.ijcard.2019.12.012 · Cited by 5
Kaya, E., Senges, J., Hochadel, M., Eckardt, L., Andresen, D., İnce, H., Spitzer, S. G., Kleemann, T., Maier, S., Jung, W., et al. (2020) · ESC Heart Failure · doi:10.1002/ehf2.12613 · Cited by 4
A case of cardiac tamponade due to coronary artery injury caused by atrial screw-in lead
Tsuji, Y., Miki, T., Sato, Y., Kojima, A., Imai, M., Kuroyanagi, A., Shiraishi, H., Shirayama, T., & Matoba, S. (2020) · Journal of Cardiology Cases · doi:10.1016/j.jccase.2020.09.011 · Cited by 4
Implantation of the Micra transcatheter pacing system: A single center North India experience
Kumar, V., Agarwal, R., Yadav, M. S., Dhir, S., & Kumar, V. (2020) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2020.10.005 · Cited by 4
Chen, K., Zhang, S., Wu, L., Liu, X., Su, Y., Zhou, Y., Zou, J., Wang, J., Xiang, M., Guo, C., et al. (2021) · International Journal of Heart Rhythm · doi:10.4103/ijhr.ijhr_4_21 · Cited by 4
Thienel, M., Haum, M., Sadoni, S., Novotny, J., Estner, H., Fichtner, S., & Lackermair, K. (2022) · Patient Preference and Adherence · doi:10.2147/ppa.s378741 · Cited by 4
Just, I. A., Barthel, F., Moter, A., Kikhney, J., Friedrich, A., Wloch, A., Falk, V., Starck, C. T., & Schoenrath, F. (2022) · EP Europace · doi:10.1093/europace/euac228 · Cited by 5
“Challenges” During Leadless Pacemaker Implantation
Le, S., Hua, J., Kong, Q., & Chen, Q. (2023) · Cardiology in Review · doi:10.1097/crd.0000000000000542 · Cited by 6
His Bundle Pacing: Predicting Mortality and Major Complications in Mid-Term Follow-Up
Kulesza, P., Gardas, R., Golba, K. S., Soral, T., Sznajder, R., Jarosiński, G., Zub, K., & Łoboda, D. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13061802 · Cited by 4
Implantable Cardioverter Defibrillator Management: an Update
Malagù, M., Ferri, A., Mancuso, O., Trevisan, F., Nardozza, M., & Bertini, M. (2016) · Future Cardiology · doi:10.2217/fca-2016-0031 · Cited by 4
Woodard, D. A., Kim, G., & Nilsson, K. R. (2022) · Cureus · doi:10.7759/cureus.24739 · Cited by 5
Looi, K., Gavin, A., Sidhu, K., Cooper, L., Dawson, L., Slipper, D., & Lever, N. A. (2018) · Journal of Arrhythmia · doi:10.1002/joa3.12134 · Cited by 3
Metadata
- Authors
- Kirkfeldt, R. E., Johansen, J. B., Nohr, E. A., Jorgensen, O. D., & Nielsen, J. C.
- Affiliations
- Odense University Hospital (DK)
- Aarhus University (DK)
- Aarhus University Hospital (DK)
- Corresponding author
- Kirkfeldt, R. E.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-12-17
- Volume
- 35
- Issue
- 18
- Pages
- 1186-1194
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- PMC
- PMC4012708
- OpenAlex
- W2109817867
- Cited by
- 871
- References
- 33
- Citations by year
- 2026: 68 · 2025: 73 · 2024: 68 · 2023: 84 · 2022: 94 · 2021: 66 · 2020: 71 · 2019: 68 · 2018: 92 · 2017: 74 · 2016: 46 · 2015: 50 · 2014: 16 · 2013: 1
- FWCI
- 25.63
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc
- Locations
- European Heart Journal (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- University of Southern Denmark Research Portal (University of Southern Denmark) (submittedVersion)
- Funders
- Hjerteforeningen
- Aarhus Universitet
- Aalborg Universitet
- Odense Universitetshospital
- Rigshospitalet
- Aalborg Universitetshospital
- Gangstedfonden
- Region Midtjylland
- Bispebjerg Hospital
- St. Jude Medical
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Emergency Medicine › Cardiac Arrest and Resuscitation
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Infective Endocarditis Diagnosis and Management
- Keywords
- cardiac implantable electronic devices, post-implantation complications, permanent pacemaker, cardiac resynchronization therapy, CRT-D, implantable cardioverter-defibrillator, dual-chamber ICD, lead revision, system upgrade, operator volume, hospital volume, risk factors
- MeSH terms
- Adolescent, Adult, Aged, Aged, 80 and over, Child, Child, Preschool, Denmark, Female, Humans, Infant, Infant, Newborn, Male, Middle Aged, Pacemaker, Artificial, Postoperative Complications, Prosthesis Failure, Risk Factors, Cohort Studies, Defibrillators, Implantable, Age Distribution, Sex Distribution, Device Removal, Young Adult, Cardiac Resynchronization Therapy Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.

