Biodegradable-polymer drug-eluting stents vs. bare metal stents vs. durable-polymer drug-eluting stents: a systematic review and Bayesian approach network meta-analysis
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The aim of this study was to compare the safety and efficacy of biodegradable-polymer (BP) drug-eluting stents (DES), bare metal stents (BMS), and durable-polymer DES in patients undergoing coronary revascularization, we performed a systematic review and network meta-analysis using a Bayesian framework. METHODS AND RESULTS: Study stents included BMS, paclitaxel-eluting (PES), sirolimus-eluting (SES), endeavor zotarolimus-eluting (ZES-E), cobalt-chromium everolimus-eluting (CoCr-EES), platinium-chromium everolimus-eluting (PtCr-EES), resolute zotarolimus-eluting (ZES-R), and BP biolimus-eluting stents (BP-BES). After a systematic electronic search, 113 trials with 90 584 patients were selected. The principal endpoint was definite or probable stent thrombosis (ST) defined according to the Academic Research Consortium within 1 year. RESULTS: Biodegradable polymer-biolimus-eluting stents [OR, 0.56; 95% credible interval (CrI), 0.33-0.90], SES (OR, 0.53; 95% CrI, 0.38-0.73), CoCr-EES (OR, 0.34; 95% CrI, 0.23-0.52), and PtCr-EES (OR, 0.31; 95% CrI, 0.10-0.90) were all superior to BMS in terms of definite or probable ST within 1 year. Cobalt-chromium everolimus-eluting stents demonstrated the lowest risk of ST of all stents at all times after stent implantation. Biodegradable polymer-biolimus-eluting stents was associated with a higher risk of definite or probable ST than CoCr-EES (OR, 1.72; 95% CrI, 1.04-2.98). All DES reduced the need for repeat revascularization, and all but PES reduced the risk of myocardial infarction compared with BMS. CONCLUSIONS: All DESs but PES and ZES-E were superior to BMS in terms of ST within 1 year. Cobalt-chromium everolimus-eluting stents was safer than any DES even including BP-BES. Our results suggest that not only the biodegradability of polymer, but the optimal combination of stent alloy, design, strut thickness, polymer, and drug all combined determine the safety of DES.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inference from iterative simulation using multiple sequences
Gelman, A., & Rubin, D. B. (1992) · Statistical Science · doi:10.1214/ss/1177011136 · Cited by 16,627 · cited 1×
“A burn-in phase of 20 000 iterations was followed by 50 000 updates, where the number of burn-in iterations was chosen according to the Brooks–Gelman– Rubin method for convergence checks.(21) Pairwise ORs were estimated from the median of the posterior distribution with CrIs taken from the 2.”
MethodClinical End Points in Coronary Stent Trials: A Case for Standardized Definitions
Cutlip, D. E., Windecker, S., Mehran, R., Boam, A., Cohen, D. J., van Es, G.-A., Gabriel Steg, P., Morel, M.-A., Mauri, L., Vranckx, P., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.685313 · Cited by 5,497
Self-citationMorice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Developed with the special contribution of the European Association for Percutaneous Cardiovascular Interventions (EAPCI), Authors/Task Force Members, Wijns, W., Kolh, P., Danchin, N., Di Mario, C., Falk, V., Folliguet, T., Garg, S., Huber, K., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq277 · Cited by 3,184
A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Pathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744
Combination of direct and indirect evidence in mixed treatment comparisons
Lu, G., & Ades, A. E. (2004) · Statistics in Medicine · doi:10.1002/sim.1875 · Cited by 2,166 · cited 1×
“We used Bayesian extension of the hierarchical random-effects model proposed by Lumley for networks of multi-arm trials.(20) Odds ratios (ORs) with 95% credible intervals (CrIs) are presented as summary statistics.”
MethodVirmani, R., Guagliumi, G., Farb, A., Musumeci, G., Grieco, N., Motta, T., Mihalcsik, L., Tespili, M., Valsecchi, O., & Kolodgie, F. D. (2004) · Circulation · doi:10.1161/01.cir.0000116202.41966.d4 · Cited by 1,469 · cited 8×
“Studies have suggested that a reaction to the durable polymer (DP) containing the drug may trigger continued inflammation and late ST.(6) –8 Therefore, developments in newer generation of DES have been focused on biocompatible polymer, biodegradablepolymer (BP) DESs, and polymer-free DESs.”
BackgroundInfluentialLate thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy
McFadden, E. P., Stabile, E., Regar, E., Cheneau, E., Ong, A. T., Kinnaird, T., Suddath, W. O., Weissman, N. J., Torguson, R., Kent, K. M., et al. (2004) · The Lancet · doi:10.1016/s0140-6736(04)17275-9 · Cited by 1,436 · cited 8×
“In particular, we confirmed the comparable efficacy of all of the newer generation DES.”
BackgroundInfluentialLate Clinical Events After Clopidogrel Discontinuation May Limit the Benefit of Drug-Eluting Stents
Pfisterer, M., Brunner-La Rocca, H. P., Buser, P. T., Rickenbacher, P., Hunziker, P., Mueller, C., Jeger, R., Bader, F., Osswald, S., & Kaiser, C. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.10.026 · Cited by 1,303 · cited 8×
“In particular, we confirmed the comparable efficacy of all of the newer generation DES.”
BackgroundInfluentialEvaluation of networks of randomized trials
Salanti, G., Higgins, J. P., Ades, A., & Ioannidis, J. P. (2008) · Statistical Methods in Medical Research · doi:10.1177/0962280207080643 · Cited by 1,078 · cited 1×
“A systematic literature review of randomized controlled trials (RCTs) comparing coronary stents was performed, and the data from the review were the basis of a multiple-treatments network meta-analysis using a Bayesian framework.(12)”
MethodPalmerini, T., Biondi-Zoccai, G., Riva, D. D., Stettler, C., Sangiorgi, D., D'Ascenzo, F., Kimura, T., Briguori, C., Sabatè, M., Kim, H.-S., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60324-9 · Cited by 959 · cited 5×
“Recent meta-analyses have shown improved safety as well as efficacy of newer-generation DESs.9 –11 However, the major limitations of the previous meta-analyses were that the proportion of patients with newer-generation DES were relatively small and thus comparisons had restricted statistical power.”
InfluentialSelf-citationEverolimus-Eluting versus Paclitaxel-Eluting Stents in Coronary Artery Disease
Stone, G. W., Rizvi, A., Newman, W., Mastali, K., Wang, J. C., Caputo, R., Doostzadeh, J., Cao, S., Simonton, C. A., Sudhir, K., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0910496 · Cited by 902
Kolandaivelu, K., Swaminathan, R., Gibson, W. J., Kolachalama, V. B., Nguyen-Ehrenreich, K.-L., Giddings, V. L., Coleman, L., Wong, G. K., & Edelman, E. R. (2011) · Circulation · doi:10.1161/circulationaha.110.003210 · Cited by 802
Kedhi, E., Joesoef, K. S., McFadden, E., Wassing, J., van Mieghem, C., Goedhart, D., & Smits, P. C. (2010) · The Lancet · doi:10.1016/s0140-6736(09)62127-9 · Cited by 687
Windecker, S., Serruys, P. W., Wandel, S., Buszman, P., Trznadel, S., Linke, A., Lenk, K., Ischinger, T., Klauss, V., Eberli, F., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)61244-1 · Cited by 653 · cited 1×
“bioabsorbable polymer (poly-lactic acid), which is known to be absorbed in the body within a few months.(27,28) In this study, BP-BES reduced the risk of definite or probable ST compared with BMS.”
ResultNakazawa, G., Finn, A. V., Joner, M., Ladich, E., Kutys, R., Mont, E. K., Gold, H. K., Burke, A. P., Kolodgie, F. D., & Virmani, R. (2008) · Circulation · doi:10.1161/circulationaha.107.762047 · Cited by 611
Bangalore, S., Kumar, S., Fusaro, M., Amoroso, N., Attubato, M. J., Feit, F., Bhatt, D. L., & Slater, J. (2012) · Circulation · doi:10.1161/circulationaha.112.097014 · Cited by 574
Sabate, M., Cequier, A., Iñiguez, A., Serra, A., Hernandez-Antolin, R., Mainar, V., Valgimigli, M., Tespili, M., den Heijer, P., Bethencourt, A., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61223-9 · Cited by 462
Stefanini, G. G., Kalesan, B., Serruys, P. W., Heg, D., Buszman, P., Linke, A., Ischinger, T., Klauss, V., Eberli, F., Wijns, W., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61672-3 · Cited by 354
Räber, L., Kelbæk, H., Ostojic, M., Baumbach, A., Heg, D., Tüller, D., von Birgelen, C., Roffi, M., Moschovitis, A., Khattab, A. A., et al. (2012) · JAMA · doi:10.1001/jama.2012.10065 · Cited by 298
Primary Endpoint Results of the EVOLVE Trial
Meredith, I. T., Verheye, S., Dubois, C. L., Dens, J., Fajadet, J., Carrié, D., Walsh, S., Oldroyd, K. G., Varenne, O., El-Jack, S., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.12.016 · Cited by 203
Mehilli, J., Pache, J., Abdel-Wahab, M., Schulz, S., Byrne, R. A., Tiroch, K., Hausleiter, J., Seyfarth, M., Ott, I., Ibrahim, T., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61255-5 · Cited by 187
Park, K. W., Kang, S., Velders, M. A., Shin, D., Hahn, S., Lim, W., Yang, H., Lee, H., van Boven, A. J., Hofma, S. H., et al. (2012) · American Heart Journal · doi:10.1016/j.ahj.2012.08.007 · Cited by 83 · cited 4×
“It has been shown in previous randomized trials that CoCr-EES reduced the risk of ST compared with PES and BMS.23– 25 Direct comparison meta-analyses suggested a risk reduction in definite ST with CoCr-EES compared with SES.11,26 In this study, we showed that the reduction in the risk of ST occurs not only in the shor…”
MethodInfluentialSelf-citationDrug-Eluting Versus Bare Metal Stents in Patients With ST-Segment–Elevation Myocardial Infarction
Kelbæk, H., Thuesen, L., Helqvist, S., Clemmensen, P. M., Kløvgaard, L., Kaltoft, A., Andersen, B., Thuesen, H., Engstrøm, T., Bøtker, H. E., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.758698 · Cited by 72
Kereiakes, D. J., Cannon, L., Feldman, R. L., Popma, J. J., Magorien, R. D., Whitbourn, R., Dauber, I. M., Rabinowitz, A. C., Ball, M. W., Bertolet, B. D., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.04.011 · Cited by 65
Everolimus-eluting versus sirolimus-eluting stents: an updated meta-analysis of randomized trials
de Waha, A., Cassese, S., Park, D., Burzotta, F., Byrne, R. A., Tada, T., King, L. A., Park, S., Schömig, A., & Kastrati, A. (2012) · Clinical Research in Cardiology · doi:10.1007/s00392-012-0414-8 · Cited by 48
Lupi, A., Rognoni, A., Secco, G. G., Lazzero, M., Nardi, F., Fattori, R., Bongo, A. S., Agostoni, P., & Sheiban, I. (2012) · European Journal of Preventive Cardiology · doi:10.1177/2047487312467745 · Cited by 32 · cited 2×
“These findings are contradictory to a recent meta-analysis that showed a trend towards lower risk of ST of BP-DES compared with DP-DES.30 However, in that study, the BP-DES was not only BP-BES, but also included two different types of BP-SES, and the DP-DES arm consisted of mostly first-generation DES.”
Result
Cited by
2018 ESC/EACTS guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy394 · Cited by 7,167
2021 ACC/AHA/SCAI Guideline for Coronary Artery Revascularization
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.09.006 · Cited by 1,558
2018 ESC/EACTS Guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · EuroIntervention · doi:10.4244/eijy19m01_01 · Cited by 1,259
2018 ESC/EACTS Guidelines on myocardial revascularization
Sousa-Uva, M., Neumann, F.-J., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezy289 · Cited by 989
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001038 · Cited by 829
Metadata
- Authors
- Kang, S.-H., Park, K. W., Kang, D.-Y., Lim, W.-H., Park, K. T., Han, J.-K., Kang, H.-J., Koo, B.-K., Oh, B.-H., Park, Y.-B., Kandzari, D. E., Cohen, D. J., Hwang, S.-S., & Kim, H.-S.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-01-23
- Volume
- 35
- Issue
- 17
- Pages
- 1147-1158
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2139804268
- Cited by
- 168
- References
- 28
- FWCI
- 6.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.