EuroEco (European Health Economic Trial on Home Monitoring in ICD Patients): a provider perspective in five European countries on costs and net financial impact of follow-up with or without remote monitoring
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
AIM: Remote follow-up (FU) of implantable cardiac defibrillators (ICDs) allows for fewer in-office visits in combination with earlier detection of relevant findings. Its implementation requires investment and reorganization of care. Providers (physicians or hospitals) are unsure about the financial impact. The primary end-point of this randomized prospective multicentre health economic trial was the total FU-related cost for providers, comparing Home Monitoring facilitated FU (HM ON) to regular in-office FU (HM OFF) during the first 2 years after ICD implantation. Also the net financial impact on providers (taking national reimbursement into account) and costs from a healthcare payer perspective were evaluated. METHODS AND RESULTS: A total of 312 patients with VVI- or DDD-ICD implants from 17 centres in six EU countries were randomised to HM ON or OFF, of which 303 were eligible for data analysis. For all contacts (in-office, calendar- or alert-triggered web-based review, discussions, calls) time-expenditure was tracked. Country-specific cost parameters were used to convert resource use into monetary values. Remote FU equipment itself was not included in the cost calculations. Given only two patients from Finland (one in each group) a monetary valuation analysis was not performed for Finland. Average age was 62.4 ± 13.1 years, 81% were male, 39% received a DDD system, and 51% had a prophylactic ICD. Resource use with HM ON was clearly different: less FU visits (3.79 ± 1.67 vs. 5.53 ± 2.32; P < 0.001) despite a small increase of unscheduled visits (0.95 ± 1.50 vs. 0.62 ± 1.25; P < 0.005), more non-office-based contacts (1.95 ± 3.29 vs. 1.01 ± 2.64; P < 0.001), more Internet sessions (11.02 ± 15.28 vs. 0.06 ± 0.31; P < 0.001) and more in-clinic discussions (1.84 ± 4.20 vs. 1.28 ± 2.92; P < 0.03), but with numerically fewer hospitalizations (0.67 ± 1.18 vs. 0.85 ± 1.43, P = 0.23) and shorter length-of-stay (6.31 ± 15.5 vs. 8.26 ± 18.6; P = 0.27), although not significant. For the whole study population, the total FU cost for providers was not different for HM ON vs. OFF [mean (95% CI): €204 (169-238) vs. €213 (182-243); range for difference (€-36 to 54), NS]. From a payer perspective, FU-related costs were similar while the total cost per patient (including other physician visits, examinations, and hospitalizations) was numerically (but not significantly) lower. There was no difference in the net financial impact on providers [profit of €408 (327-489) vs. €400 (345-455); range for difference (€-104 to 88), NS], but there was heterogeneity among countries, with less profit for providers in the absence of specific remote FU reimbursement (Belgium, Spain, and the Netherlands) and maintained or increased profit in cases where such reimbursement exists (Germany and UK). Quality of life (SF-36) was not different. CONCLUSION: For all the patients as a whole, FU-related costs for providers are not different for remote FU vs. purely in-office FU, despite reorganized care. However, disparity in the impact on provider budget among different countries illustrates the need for proper reimbursement to ensure effective remote FU implementation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Varma, N., Epstein, A. E., Irimpen, A., Schweikert, R., & Love, C. (2010) · Circulation · doi:10.1161/circulationaha.110.937409 · Cited by 594 · cited 2×
“All stakeholders see potential benefits: physicians and hospitals (the ‘providers’) may optimize performance by reducing the number of in-hospital visits, while specialist nurses and/or technicians can filter alerts from the remote system, hence possibly saving physician time.(1) For patients, the technology provides…”
BackgroundThe CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) Trial
Crossley, G. H., Boyle, A., Vitense, H., Chang, Y., & Mead, R. H. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.012 · Cited by 526 · cited 1×
“Prior trials have shown that such FU is non-inferior clinically from a major events perspective, and even has clinical advantages like earlier actionability on clinical- or device-related findings, fewer and shorter hospitalizations, fewer inappropriate shocks, longer battery longevity, and even lower mortality.(1,6,7…”
BackgroundA randomized trial of long-term remote monitoring of pacemaker recipients (The COMPAS trial)
Mabo, P., Victor, F., Bazin, P., Ahres, S., Babuty, D., Da Costa, A., Binet, D., & Daubert, J.-C. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr419 · Cited by 347 · cited 4×
“8 Especially daily remote monitoring results in earlier detection of device and patient-related problems which translate into earlier clinical decision-making, less inappropriate shocks and improved device longevity.(7) – 9 The CONNECT trial also showed a significant reduction in the length of cardiovascular hospitali…”
BackgroundResultInfluentialAL‐KHATIB, S. M., PICCINI, J. P., KNIGHT, D., STEWART, M., CLAPP‐CHANNING, N., & SANDERS, G. D. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01659.x · Cited by 114 · cited 2×
“Prior trials have shown that such FU is non-inferior clinically from a major events perspective, and even has clinical advantages like earlier actionability on clinical- or device-related findings, fewer and shorter hospitalizations, fewer inappropriate shocks, longer battery longevity, and even lower mortality.(1,6,7…”
Background
Cited by
Slotwiner, D., Varma, N., Akar, J. G., Annas, G., Beardsall, M., Fogel, R. I., Galizio, N. O., Glotzer, T. V., Leahy, R. A., Love, C. J., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.05.008 · Cited by 532
Boriani, G., Da Costa, A., Quesada, A., Ricci, R. P., Favale, S., Boscolo, G., Clementy, N., Amori, V., Mangoni di S. Stefano, L., & Burri, H. (2017) · European Journal of Heart Failure · doi:10.1002/ejhf.626 · Cited by 213
Does remote patient monitoring reduce acute care use? A systematic review
Taylor, M. L., Thomas, E. E., Snoswell, C. L., Smith, A. C., & Caffery, L. J. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-040232 · Cited by 146
Klersy, C., Boriani, G., De Silvestri, A., Mairesse, G. H., Braunschweig, F., Scotti, V., Balduini, A., Cowie, M. R., Leyva, F., & for the Health Economics Committee of the European Heart Rhythm Association (2016) · European Journal of Heart Failure · doi:10.1002/ejhf.470 · Cited by 120
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y.-F., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.009204 · Cited by 74
Self-citation
Metadata
- Authors
- Heidbuchel, H., Hindricks, G., Broadhurst, P., Van Erven, L., Fernandez-Lozano, I., Rivero-Ayerza, M., Malinowski, K., Marek, A., Garrido, R. F. R., Loscher, S., Beeton, I., Garcia, E., Cross, S., Vijgen, J., Koivisto, U.-M., Peinado, R., Smala, A., & Annemans, L.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-09-01
- Volume
- 36
- Issue
- 3
- Pages
- 158-169
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2160441648
- Cited by
- 115
- References
- 4
- FWCI
- 10.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: EuroEco (European Health Economic Trial on Home Monitoring in ICD Patients): a provider perspective in five European countries on costs and net financial impact of follow-up with or without remote monitoring. https://app.cochat.ai/papers/10.1093/eurheartj/ehu339
- The paper
- Heidbuchel, H., Hindricks, G., Broadhurst, P., Van Erven, L., Fernandez-Lozano, I., Rivero-Ayerza, M., Malinowski, K., Marek, A., Garrido, R. F. R., Loscher, S., Beeton, I., Garcia, E., Cross, S., Vijgen, J., Koivisto, U.-M., Peinado, R., Smala, A., & Annemans, L. (2015). EuroEco (European Health Economic Trial on Home Monitoring in ICD Patients): a provider perspective in five European countries on costs and net financial impact of follow-up with or without remote monitoring. European Heart Journal. https://doi.org/10.1093/eurheartj/ehu339
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.