Remote Monitoring of Implantable Cardioverter Defibrillators versus Quarterly Device Interrogations in Clinic: Results from a Randomized Pilot Clinical Trial
Abstract
ICD: Remote Monitoring Versus Clinic Interrogations. Introduction:Remote monitoring is increasingly becoming the new standard of care for implantable cardioverter defibrillator (ICD) follow‐up. We sought to determine whether remote monitoring of ICDs improves patient outcomes compared with quarterly device interrogations in clinic. Methods and Results:In this single‐center pilot clinical trial, adult patients with an ICD were randomly assigned to remote monitoring versus quarterly device interrogations in clinic. The primary endpoint was a composite of cardiovascular hospitalization, emergency room visit for a cardiac cause, and unscheduled visit to the electrophysiology clinic for a device‐related issue at 1 year. We also examined health‐related quality of life, costs, and patient satisfaction with their ICD care. Of 151 patients enrolled in this trial, 76 were randomized to remote monitoring and 75 to quarterly device interrogations in clinic. There was no significant difference in the primary endpoint (32% in the remote monitoring arm vs 34% in the control arm; P = 0.8), mortality, or cost between the 2 arms. Quality of life and patient satisfaction were significantly better in the control arm than in the remote monitoring arm at 6 months (83 [25th, 75th percentiles 70, 90] vs 75 [50, 85]; P = 0.002 and 88 [75, 100] vs 75 [75, 88]; P = 0.03, respectively), but not at 12 months. Conclusion:We showed no significant reduction in cardiac‐related resource utilization with remote monitoring of ICDs. However, given the small number of patients in our study, the real clinical and health economics impact of remote monitoring needs to be verified by a large, multicenter, randomized clinical trial.(J Cardiovasc Electrophysiol, Vol. 21, pp. 545‐550, May 2010)
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Data on the cost benefits of remote monitoring are not definitive to date.
“Data on the cost benefits of remote monitoring are not definitive to date.52,56”
From Managing with pacemakers and implantable cardioverter defibrillators (2013) · cites this paper as [56]
Cites
EuroQol: a new facility for the measurement of health-related quality of life
(1990) · Health Policy · doi:10.1016/0168-8510(90)90421-9 · Cited by 15,736 · see citing works
Cost-Effectiveness in Health and Medicine
(1996) · doi:10.1093/oso/9780195108248.001.0001 · Cited by 7,193 · see citing works
Moss, A. J., Zaręba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,885 · see citing works
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552 · see citing works
Self-citationThe Effect of Cardiac Resynchronization on Morbidity and Mortality in Heart Failure
Cleland, J. G. F., Daubert, J., Erdmann, E., Freemantle, N., Gras, D., KAPPENBERGER, L. J., & Tavazzi, L. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa050496 · Cited by 6,258 · see citing works
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812 · see citing works
Prophylactic Defibrillator Implantation in Patients with Nonischemic Dilated Cardiomyopathy
Kadish, A. H., Dyer, A. R., Daubert, J. P., Quigg, R. J., Estes, N. A. M., Anderson, K. P., Calkins, H. G., Hoch, D., Goldberger, J. J., Shalaby, A. A., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa033088 · Cited by 2,064 · see citing works
Oss, J. M., Areba, W. O. Z., Ackson, W. J., Lein, H. E. K., Ilber, D. A. J. W., Annom, D. A. S. C., Ames, J. M., Aubert, P., Iggins, S. T. L. H., Rown, M. A. W. B., et al. (2002) · Cited by 2,026 · see citing works
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,768 · see citing works
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.014 · Cited by 550 · see citing works
Quality of Life with Defibrillator Therapy or Amiodarone in Heart Failure
Mark, D. B., Anstrom, K. J., Sun, J. L., Clapp-Channing, N. E., Tsiatis, A. A., Davidson-Ray, L., Lee, K. L., & Bardy, G. H. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0706719 · Cited by 260 · see citing works
Self-citationRaatikainen, M. J. P., Uusimaa, P., van Ginneken, M. M. E., Janssen, J. P. G., & Linnaluoto, M. (2008) · Europace · doi:10.1093/europace/eun203 · Cited by 189 · see citing works
MARZEGALLI, M., LUNATI, M., LANDOLINA, M., PEREGO, G. B., RICCI, R. P., GUENZATI, G., SCHIRRU, M., BELVITO, C., BRAMBILLA, R., MASELLA, C., et al. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.01175.x · Cited by 134 · see citing works
Santini, M., Ricci, R. P., Lunati, M., Landolina, M., Perego, G. B., Marzegalli, M., Schirru, M., Belvito, C., Brambilla, R., Guenzati, G., et al. (2008) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-008-9321-3 · Cited by 71 · see citing works
Varma, N. (2007) · American Heart Journal · doi:10.1016/j.ahj.2007.07.051 · Cited by 57 · see citing works
(2004) · ACC Current Journal Review · doi:10.1016/j.accreview.2004.07.039 · Cited by 39 · see citing works
Crossley, G. H., Boyle, A., Vitense, H. S., Sherfesee, L., & Mead, R. H. (2008) · American Heart Journal · doi:10.1016/j.ahj.2008.06.028 · Cited by 37 · see citing works
The EuroQol© quality of life project
Rosser, R., & Sintonen, H. (1993) · Springer eBooks · doi:10.1007/978-94-011-2988-6_10 · Cited by 12 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Interactive telemedicine: effects on professional practice and health care outcomes
Flodgren, G., Rachas, A., Farmer, A. J., Inzitari, M., & Shepperd, S. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002098.pub2 · Cited by 806 · see citing works
Slotwiner, D. J., Varma, N., Akar, J. G., Annas, G. J., Beardsall, M., Fogel, R. I., Galizio, N. O., Glotzer, T. V., Leahy, R. A., Love, C. J., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.05.008 · Cited by 533 · see citing works
Remote Monitoring of Implantable Cardioverter-Defibrillators
Parthiban, N., Esterman, A., Mahajan, R., Twomey, D. J., Pathak, R. K., Lau, D. H., Roberts‐Thomson, K. C., Young, G. D., Sanders, P., & Ganesan, A. N. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.04.029 · Cited by 247 · see citing works
Boriani, G., Costa, A. D., Quesada, A., Ricci, R. P., Favale, S., Boscolo, G., Clémenty, N., Amori, V., Stefano, L. M. D. S., & Burri, H. (2016) · European Journal of Heart Failure · doi:10.1002/ejhf.626 · Cited by 213 · see citing works
Shameer, K., Badgeley, M. A., Miotto, R., Glicksberg, B. S., Morgan, J. W., & Dudley, J. T. (2017) · Briefings in Bioinformatics · doi:10.1093/bib/bbv118 · Cited by 198 · see citing works
Pandor, A., Thokala, P., Gomersall, T., Baalbaki, H., Stevens, J., Wang, J., Wong, R., Brennan, A., & Fitzgerald, P. (2013) · Health Technol Assess · doi:10.3310/hta17320 · Cited by 159 · see citing works
Klersy, C., Boriani, G., De Silvestri, A., Mairesse, G. H., Braunschweig, F., Scotti, V., Balduini, A., Cowie, M. R., Leyva, F., & for the Health Economics Committee of the European Heart Rhythm Association (2016) · European Journal of Heart Failure · doi:10.1002/ejhf.470 · Cited by 120 · see citing works
Heidbüchel, H., Hindricks, G., Broadhurst, P., van Erven, L., Lozano, I. F., Rivero‐Ayerza, M., MALINOWSKI, K., Marek, A., Garrido, R. R., Löscher, S., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu339 · Cited by 115 · see citing works
Telemedicine and cardiac implants: what is the benefit?
Varma, N., & Ricci, R. P. (2013) · European Heart Journal · doi:10.1093/eurheartj/ehs388 · Cited by 102 · see citing works
Remote Monitoring Alert Burden
O’Shea, C., Middeldorp, M. E., Hendriks, J., Brooks, A. G., Lau, D. H., Emami, M., Mishima, R. S., Thiyagarajah, A., Feigofsky, S. A., Gopinathannair, R., et al. (2020) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2020.08.029 · Cited by 82 · see citing works
Zanaboni, P., Landolina, M., Marzegalli, M., Lunati, M., Perego, G. B., Guenzati, G., Curnis, A., Valsecchi, S., Borghetti, F., Borghi, G., et al. (2013) · Journal of Medical Internet Research · doi:10.2196/jmir.2587 · Cited by 76 · see citing works
EHDViz: clinical dashboard development using open-source technologies
Badgeley, M. A., Shameer, K., Glicksberg, B. S., Tomlinson, M., Levin, M. A., McCormick, P. J., Kasarskis, A., Reich, D. L., & Dudley, J. T. (2016) · BMJ Open · doi:10.1136/bmjopen-2015-010579 · Cited by 66 · see citing works
Socio-economic effects and cost saving potential of remote patient monitoring (SAVE-HM trial)
Perl, S., Stiegler, P., Rotman, B., Prenner, G., Lercher, P., Anelli-Monti, M., Sereinigg, M., Riegelnik, V., Kvas, E., Kos, C., et al. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.10.019 · Cited by 65 · see citing works
Leo, D. G., Buckley, B. J. R., Chowdhury, M., Harrison, S. L., Isanejad, M., Lip, G. Y. H., Wright, D. J., Lane, D. A., & the TAILOR investigators (2022) · Journal of Medical Internet Research · doi:10.2196/35508 · Cited by 62 · see citing works
Svennberg, E., Caiani, E. G., Bruining, N., Desteghe, L., Han, J. K., Narayan, S. M., Rademakers, F. E., Sanders, P., & Duncker, D. (2023) · EP Europace · doi:10.1093/europace/euad176 · Cited by 64 · see citing works
Patient satisfaction and suggestions for improvement of remote ICD monitoring
Petersen, H. H., Larsen, M. C. J., Nielsen, O. W., Kensing, F., & Svendsen, J. H. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9675-4 · Cited by 57 · see citing works
Yee, R., Verma, A., Beardsall, M., Fraser, J. A., Philippon, F., & Exner, D. V. (2013) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2012.11.036 · Cited by 54 · see citing works
Timmermans, I., Meine, M., Szendey, I., Aring, J., Roldán, J. R., van Erven, L., Kahlert, P., Zitron, E., Mabo, P., Denollet, J., et al. (2018) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13574 · Cited by 53 · see citing works
Remote monitoring and telemedicine in heart failure: implementation and benefits
Imberti, J. F., Tosetti, A., Mei, D. A., Maisano, A., & Boriani, G. (2021) · Current Cardiology Reports · doi:10.1007/s11886-021-01487-2 · Cited by 53 · see citing works
Calò, L., Gargaro, A., Ruvo, E. D., Palozzi, G., Sciarra, L., Rebecchi, M., Guarracini, F., Fagagnini, A., Piroli, E., Lioy, E., et al. (2013) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-013-9783-9 · Cited by 47 · see citing works
Remote monitoring of cardiac implantable electronic devices (CIED)
Zeitler, E. P., & Piccini, J. P. (2016) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2016.03.012 · Cited by 46 · see citing works
Self-citationPerformance of first pacemaker to use smart device app for remote monitoring
Tarakji, K. G., Zaidi, A. M., ZWEIBEL, S. L., Varma, N., Sears, S. F., Allred, J. D., Roberts, P. R., Shaik, N. A., Silverstein, J. R., Maher, A. R., et al. (2021) · Heart Rhythm O2 · doi:10.1016/j.hroo.2021.07.008 · Cited by 42 · see citing works
Compliance with Remote Monitoring of ICDS/CRTDS in a Real‐World Population
Rosenfeld, L. E., Patel, A. S., Ajmani, V. B., Holbrook, R., & BRAND, T. A. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12358 · Cited by 40 · see citing works
Skov, M. B., Johansen, P. G., Skov, C. S., & Lauberg, A. (2015) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/2702123.2702192 · Cited by 40 · see citing works
VOGTMANN, T., Stiller, S., Marek, A., Kespohl, S., Gomer, M., Kühlkamp, V., Zach, G., Löscher, S., & Baumann, G. (2012) · EP Europace · doi:10.1093/europace/eus252 · Cited by 39 · see citing works
Versteeg, H., Timmermans, I., Widdershoven, J. W. M. G., KIMMAN, G. P., Prévôt, S., Rauwolf, T., SCHOLTEN, M. F., Zitron, E., Mabo, P., Denollet, J., et al. (2019) · EP Europace · doi:10.1093/europace/euz140 · Cited by 38 · see citing works
Alotaibi, S. R., Hernández-Montfort, J., Ali, O. E., Chilali, K. E., & Perez-Villa, B. (2020) · Heart Failure Reviews · doi:10.1007/s10741-020-09923-1 · Cited by 38 · see citing works
(2018) · Europe PMC (PubMed Central) · Cited by 38 · see citing works
Burri, H., Quesada, A., Ricci, R. P., Boriani, G., Davinelli, M., Favale, S., Costa, A. D., Kautzner, J., Moser, R., Navarro, X., et al. (2010) · American Heart Journal · doi:10.1016/j.ahj.2010.04.005 · Cited by 36 · see citing works
Managing with pacemakers and implantable cardioverter defibrillators
Lampert, R. (2013) · Circulation · doi:10.1161/circulationaha.113.001555 · Cited by 34 · see citing works
Dario, C., Delise, P., Gubian, L., Saccavini, C., BRANDOLINO, G., & Mancin, S. (2016) · Interactive Journal of Medical Research · doi:10.2196/ijmr.4270 · Cited by 35 · see citing works
Remote monitoring and follow-up of cardiovascular implantable electronic devices in the Netherlands
de Cock, C. C., Elders, J., van Hemel, N. M., van den Broek, K., van Erven, L., de Mol, B. A. J. M., Talmon, J. L., Theuns, D. A. M. J., & de Voogt, W. (2012) · Netherlands Heart Journal · doi:10.1007/s12471-011-0239-5 · Cited by 34 · see citing works
Workflow, time and patient satisfaction from the perspectives of Home Monitoring
Ricci, R. P., & Morichelli, L. (2013) · EP Europace · doi:10.1093/europace/eut113 · Cited by 34 · see citing works
Versteeg, H., Pedersen, S. S., Mastenbroek, M. H., Redekop, W. K., Schwab, J. O., Mabo, P., & Meine, M. (2014) · Netherlands Heart Journal · doi:10.1007/s12471-014-0587-z · Cited by 32 · see citing works
Braunschweig, F., Anker, S. D., Proff, J., & Varma, N. (2019) · EP Europace · doi:10.1093/europace/euz011 · Cited by 31 · see citing works
Home Telehealth for Chronic Disease Management: Selected Findings of a Narrative Synthesis
Jones, A., Hedges-Chou, J., Bates, J., Loyola, M., Lear, S. A., & Jarvis-Selinger, S. (2014) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2013.0249 · Cited by 31 · see citing works
Jang, J.-P., Lin, H.-T., Chen, Y.-J., HSIEH, M., & Huang, Y. (2020) · Circulation Journal · doi:10.1253/circj.cj-20-0633 · Cited by 30 · see citing works
Transparent sharing of digital health data: A call to action
Slotwiner, D. J., Tarakji, K. G., Al‐Khatib, S. M., PASSMAN, R. S., Saxon, L. A., Peters, N. S., McCall, D., Turakhia, M. P., Schaeffer, J., Mendenhall, G. S., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.04.042 · Cited by 29 · see citing works
Self-citationWatanabe, E., Kasai, A., Fujii, E., Yamashiro, K., & Brugada, P. (2013) · Circulation Journal · doi:10.1253/circj.cj-13-0387 · Cited by 28 · see citing works
Remote monitoring of heart failure: benefits for therapeutic decision making
Martirosyan, M., Çalişkan, K., Theuns, D. A. M. J., & Szili‐Törok, T. (2017) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2017.1348229 · Cited by 28 · see citing works
Remote monitoring of implantable cardiac devices
Ganeshan, R., Enriquez, A. D., & Freeman, J. V. (2017) · Current Opinion in Cardiology · doi:10.1097/hco.0000000000000471 · Cited by 27 · see citing works
Kelly, S., Campbell, D., Duhn, L., Giddens, K., Gillis, A. M., AbdelWahab, A. M., Nault, I., Raj, S. R., Lockwood, E. E., Basta, J., et al. (2020) · CJC Open · doi:10.1016/j.cjco.2020.11.010 · Cited by 27 · see citing works
Hummel, J. P., Leipold, R. J., Amorosi, S. L., Bao, H., Deger, K. A., Jones, P. W., Kansal, A. R., Ott, L. S., Stern, S., Steín, K. M., et al. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13934 · Cited by 25 · see citing works
Hafkamp, F. J., Tio, R. A., Otterspoor, L., Greef, T. V.-D., van Steenbergen, G. J., van de Ven, A. R. T., Smits, G., Post, H., & van Veghel, D. (2022) · Heart Failure Reviews · doi:10.1007/s10741-021-10212-8 · Cited by 24 · see citing works
Perings, C. A., Bauer, W., Bondke, H., Mewis, C., James, M., Böcker, D., Broadhurst, P., Korte, T., Toft, E., Hintringer, F., et al. (2011) · EP Europace · doi:10.1093/europace/euq447 · Cited by 22 · see citing works
Remote follow-up of pacemakers in a selected population of debilitated elderly patients
Folino, A. F., Breda, R., Calzavara, P., Borghetti, F., COMISSO, J., Iliceto, S., & Buja, G. (2012) · EP Europace · doi:10.1093/europace/eus351 · Cited by 22 · see citing works
Success of pacemaker remote monitoring using app‐based technology: Does patient age matter?
Tarakji, K. G., Vives, C. A., Patel, A. S., Fagan, D. H., Sims, J., & Varma, N. (2018) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13461 · Cited by 22 · see citing works
Morichelli, L., Porfili, A., Quarta, L., Sassi, A., & Ricci, R. P. (2014) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-014-9935-6 · Cited by 21 · see citing works
Ruvo, E. D., Gargaro, A., Sciarra, L., Luca, L. D., Zuccaro, L. M., Stirpe, F., Rebecchi, M., Sette, A., Lioy, E., & Calò, L. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02932.x · Cited by 20 · see citing works
Sequeira, S., Jarvis, C. I., Benchouche, A., Seymour, J., & Tadmouri, A. (2020) · EP Europace · doi:10.1093/europace/euaa082 · Cited by 20 · see citing works
Ottenberg, A. L., Swetz, K. M., Mueller, L. A., Gerhardson, S., & Mueller, P. S. (2013) · Heart & Lung · doi:10.1016/j.hrtlng.2013.03.002 · Cited by 19 · see citing works
Cronin, E. M., & Varma, N. (2012) · Expert Review of Medical Devices · doi:10.1586/erd.12.18 · Cited by 17 · see citing works
Leppert, F., Siebermair, J., Wesemann, U., Martens, E., Sattler, S. M., Scholz, S. M., Veith, S., Greiner, W., Rassaf, T., Kääb, S., et al. (2020) · Clinical Research in Cardiology · doi:10.1007/s00392-020-01667-0 · Cited by 17 · see citing works
Pron, G. E., Ieraci, L., & Kaulback, K. (2012) · Europe PMC (PubMed Central) · Cited by 17 · see citing works
Timmermans, I., Meine, M., Zitron, E., Widdershoven, J. W. M. G., Kimman, G., Prévôt, S., Rauwolf, T., Anselme, F., Szendey, I., Roldán, J. R., et al. (2017) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13123 · Cited by 16 · see citing works
Telemonitoring of implantable cardiac devices: hurdles towards personalised medicine
Heidbuchel, H. (2011) · Heart · doi:10.1136/hrt.2009.188789 · Cited by 15 · see citing works
van der Velde, E. T., Foeken, H., Witteman, T. A., van Erven, L., & Schalij, M. J. (2012) · Netherlands Heart Journal · doi:10.1007/s12471-011-0234-x · Cited by 14 · see citing works
Remote monitoring of patients with implanted devices: data exchange and integration
van der Velde, E. T., Atsma, D. E., Foeken, H., Witteman, T. A., & Hoekstra, W. H. G. J. (2013) · European Journal of Preventive Cardiology · doi:10.1177/2047487313487483b · Cited by 14 · see citing works
Mhanna, M., Beran, A., Nazir, S., Al‐Abdouh, A., Barbarawi, M., Sajdeya, O., Srour, O., Altujjar, M., Patel, R. B., & Eltahawy, E. A. (2021) · Heart Failure Reviews · doi:10.1007/s10741-021-10176-9 · Cited by 13 · see citing works
Mittal, S., Movsowitz, C., & Varma, N. (2014) · Cardiology Clinics · doi:10.1016/j.ccl.2014.01.001 · Cited by 12 · see citing works
M�ller, A. A., Thomas, M., Wildau, H.-J., Otto, J. U., & Zugck, C. (2011) · InTech eBooks · doi:10.5772/13329 · Cited by 12 · see citing works
Sapp, J. A., Gillis, A. M., AbdelWahab, A. M., Nault, I., Nery, P. B., Healey, J. S., Raj, S. R., Lockwood, E. E., Sterns, L. D., Sears, S. F., et al. (2021) · CMAJ Open · doi:10.9778/cmajo.20200041 · Cited by 11 · see citing works
Nutzenbewertung des strukturierten Telemonitorings mithilfe von aktiven Herzrhythmusimplantaten
Stockburger, M. A., Helms, T. M., Perings, C. A., Deneke, T., Köhler, F., Leonhardt, V., Muller, A. M., Piorkowski, C., Rybak, K., & Sack, S. (2017) · Der Kardiologe · doi:10.1007/s12181-017-0203-8 · Cited by 10 · see citing works
Impact of Remote Cardiac Monitoring on Greenhouse Gas Emissions
Bawa, D., Ahmed, A., Darden, D. J., Kabra, R., Garg, J., bansal, S. L., Olsen, E., Atkins, D., Rahim, A., Pham, N. K., et al. (2023) · JACC Advances · doi:10.1016/j.jacadv.2023.100286 · Cited by 10 · see citing works
Folino, A. F., Chiusso, F., Zanotto, G., Vaccari, D., GASPARINI, G., Megna, M., Marras, E., Mantovan, R., Vaglio, A., Boscolo, G., et al. (2011) · EP Europace · doi:10.1093/europace/eur154 · Cited by 10 · see citing works
Contemporary Advances in Cardiac Remote Monitoring: A Comprehensive, Updated Mini-Review
Preda, A., Falco, R., Tognola, C., Carbonaro, M., Vargiu, S., Gallazzi, M., Baroni, M., Gigli, L., Varrenti, M., Colombo, G., et al. (2024) · Medicina · doi:10.3390/medicina60050819 · Cited by 8 · see citing works
Remote Monitoring of Cardiac Implantable Electronic Devices: What is the Evidence?
Reinhardt, A., & Ventura, R. (2023) · Current Heart Failure Reports · doi:10.1007/s11897-023-00586-1 · Cited by 8 · see citing works
de Graaf, G., Timmermans, I., Meine, M., Alings, M., Pedersen, S. S., Mabo, P., Zitron, E., Redekop, K., & Versteeg, H. (2022) · Journal of Telemedicine and Telecare · doi:10.1177/1357633x221129176 · Cited by 7 · see citing works
Theuns, D. A. M. J., & Jordaens, L. J. L. M. (2011) · Netherlands Heart Journal · doi:10.1007/s12471-011-0228-8 · Cited by 7 · see citing works
Al‐Abdouh, A., Mhanna, M., Sayaideh, M. A., Barbarawi, M., Abusnina, W. A., Jabri, A., Alzu’bi, H., Rmilah, A. A. A., Haq, I.-U., Kumar, A., et al. (2022) · Current Heart Failure Reports · doi:10.1007/s11897-022-00579-6 · Cited by 6 · see citing works
Cardiac Resynchronization Therapy Follow-up
Linde, C. M., & Braunschweig, F. (2015) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2015.08.010 · Cited by 6 · see citing works
Raes, S., Prezzi, A., Willems, R., Heidbüchel, H., & Annemans, L. (2024) · Journal of Medical Internet Research · doi:10.2196/47616 · Cited by 5 · see citing works
Automatic remote monitoring: is there a need?
Varma, N., & Brugada, P. (2013) · EP Europace · doi:10.1093/europace/eut117 · Cited by 5 · see citing works
FREEDBERG, N. A., & Feldman, A. Z. (2014) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12415 · Cited by 5 · see citing works
Laksman, Z., Krahn, A. D., Dorian, P., Simpson, C. S., Crystal, E., Healey, J. S., Khaykin, Y., Wang, X., & Lee, D. S. (2014) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2014.03.028 · Cited by 5 · see citing works
Cardiac Resynchronization Therapy Follow-up
Linde, C. M., & Braunschweig, F. (2016) · Heart Failure Clinics · doi:10.1016/j.hfc.2016.07.020 · Cited by 5 · see citing works
Callum, K., Graune, C., Bowman, E., Molden, E., & Leslie, S. J. (2021) · World Journal of Cardiology · doi:10.4330/wjc.v13.i3.46 · Cited by 5 · see citing works
Lampert, R. J. (2010) · Circulation · doi:10.1161/circulationaha.110.991687 · Cited by 5 · see citing works
Veres, B., Kiss, B., Fehérvári, P., Engh, M. A., Hegyi, P., Zima, E., Merkely, B. P., & Kosztin, A. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14124278 · Cited by 4 · see citing works
Remote monitoring of ICDs and CRTs
Varma, N. (2013) · Journal of Arrhythmia · doi:10.1016/j.joa.2013.05.001 · Cited by 4 · see citing works
Wpływ kardiowertera-defibrylatora na jakość życia — przegląd badań
Kuśmierz, M., Wleklik, M., Uchmanowicz, I., & Jaroch, J. (2016) · Folia Cardiologica · doi:10.5603/fc.2016.0004 · Cited by 4 · see citing works
Tan, V. H., Tow, H. X. S., Fong, K. Y., Wang, Y., Yeo, C., Ching, C. K., & Lim, T. W. (2024) · Journal of Arrhythmia · doi:10.1002/joa3.13054 · Cited by 4 · see citing works
Varma, N. (2013) · EP Europace · doi:10.1093/europace/eut065 · Cited by 4 · see citing works
Advances in implantable cardioverter defibrillator therapy
Rickard, J., & Wilkoff, B. L. (2015) · Expert Review of Cardiovascular Therapy · doi:10.1586/14779072.2016.1131124 · Cited by 3 · see citing works
Cascini, F., Pantović, A., Al‐Ajlouni, Y. A., Ta’ani, O. A., Failla, G., Melnyk, A., Barach, P. R., & Ricciardi, W. (2023) · Telehealth and Medicine Today · doi:10.30953/thmt.v8.415 · Cited by 4 · see citing works
Devicebasiertes Telemonitoring
Duncker, D., Michalski, R., Müller‐Leisse, J., Zormpas, C., König, T., & Veltmann, C. (2017) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-017-0521-3 · Cited by 3 · see citing works
Cost accounting del follow-up annuo per il controllo remoto dei defibrillatori impiantabili
Calò, L., Chirico, A., & Palozzi, G. (2014) · MECOSAN · doi:10.3280/mesa2014-090005 · Cited by 3 · see citing works
van Steenbergen, G. J., Jaddi, O. B., Theuns, D. A. M. J., van Veghel, D., Dekker, L., & Simmers, T. (2021) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14390 · Cited by 2 · see citing works
Adenosine test during confined pulmonary vein fibrillation: how to identify the dormant conduction?
Miyazaki, S., Kusa, S., & Iesaka, Y. (2013) · EP Europace · doi:10.1093/europace/eut035 · Cited by 2 · see citing works
Franke, J., Zugck, C., & Katus, H. A. (2013) · Der Kardiologe · doi:10.1007/s12181-013-0514-3 · Cited by 2 · see citing works
Advances in Remote Monitoring of Implantable Cardiac Devices
Varma, N., & Wilkoff, B. L. (2011) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2011.05.011 · Cited by 1 · see citing works
Cascini, F., Pantović, A., Al‐Ajlouni, Y. A., Ta'ani, O. A., Failla, G., Melnyk, A., Barach, P. R., & Ricciardi, W. (2023) · Telehealth and Medicine Today · doi:10.30953/tmt.v8.415 · Cited by 1 · see citing works
Follow-up Monitoring of Cardiac Implantable Electronic Devices
Varma, N. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-1616-0.00032-1 · Cited by 1 · see citing works
A telemonitorozás lehetőségei beültethető kardiális elektronikus eszközökkel
Zima, E., Dér, G., Bárány, T., Németh, T., Molnár, L., Osztheimer, I., Szilágyi, S., Király, Á., Papp, R., Tarjanyi, Z., et al. (2017) · Cardiologia Hungarica · doi:10.26430/chungarica.2017.47.4.281 · Cited by 1 · see citing works
Remote Monitoring of Cardiac Implantable Electronic Devices
Zeitler, E. P., Greenfield, R. A., & Piccini, J. P. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-44733-1.00122-x · Cited by 1 · see citing works
Self-citationRemote Heart Rhythm Monitoring
Gomes, J. A. (2020) · Springer eBooks · doi:10.1007/978-3-030-45066-3_35 · Cited by 1 · see citing works
van der Velde, E. T., Foeken, H., Witteman, T. A., van Erven, L., & Schalij, M. J. (2011)
Chen, J. (2014) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2014.03.001
Zanaboni, P., Landolina, M., Borghetti, F., Borghi, G., & di Carlo, S. (2014)
- Authors
- AL‐KHATIB, S. M., PICCINI, J. P., KNIGHT, D., STEWART, M., CLAPP‐CHANNING, N., & SANDERS, G. D.
- Affiliations
- Duke Medical Center (US)
- Duke Clinical Research Institute (US)
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2010-04-15
- Volume
- 21
- Issue
- 5
- Pages
- 545-550
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2086481724
- Cited by
- 114
- References
- 18
- Citations by year
- 2025: 3 · 2024: 3 · 2023: 5 · 2022: 4 · 2021: 6 · 2020: 8 · 2019: 5 · 2018: 4 · 2017: 8 · 2016: 11 · 2015: 8 · 2014: 12 · 2013: 16 · 2012: 9
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Cardiovascular Electrophysiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- implantable cardioverter-defibrillator, remote monitoring, device interrogation, ICD follow-up, health-related quality of life, patient satisfaction, health care costs, resource utilization (health care), cardiovascular hospitalization, emergency department visits
- MeSH terms
- Aged, Anti-Arrhythmia Agents, Arrhythmias, Cardiac, Cost-Benefit Analysis, Cost Control, Female, Humans, Male, Middle Aged, Monitoring, Physiologic, Office Visits, Pilot Projects, Quality of Life, Telephone, Treatment Outcome, Patient Satisfaction, Defibrillators, Implantable, Endpoint Determination
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review