Clinical trial design principles and endpoint definitions for transcatheter mitral valve repair and replacement: part 2: endpoint definitions: A consensus document from the Mitral Valve Academic Research Consortium
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Mitral regurgitation (MR) is one of the most prevalent valve disorders and has numerous aetiologies, including primary (organic) MR, due to underlying degenerative/structural mitral valve (MV) pathology, and secondary (functional) MR, which is principally caused by global or regional left ventricular remodelling and/or severe left atrial dilation. Diagnosis and optimal management of MR requires integration of valve disease and heart failure specialists, MV cardiac surgeons, interventional cardiologists with expertise in structural heart disease, and imaging experts. The introduction of trans- catheter MV therapies has highlighted the need for a consensus approach to pragmatic clinical trial design and uniform endpoint definitions to evaluate outcomes in patients with MR. The Mitral Valve Academic Research Consortium is a collaboration between leading academic research organizations and physician-scientists specializing in MV disease from the United States and Europe. Three in-person meetings were held in Virginia and New York during which 44 heart failure, valve, and imaging experts, MV surgeons and interventional cardiologists, clinical trial specialists and statisticians, and representatives from the U.S. Food and Drug Administration considered all aspects of MV pathophysiology, prognosis, and therapies, culminating in a 2-part document describing consensus recommendations for clinical trial design (Part 1) and endpoint definitions (Part 2) to guide evaluation of transcatheter and surgical therapies for MR. The adoption of these recommendations will afford robustness and consistency in the comparative effectiveness evaluation of new devices and approaches to treat MR. These principles may be useful for regulatory assessment of new transcatheter MV devices, as well as for monitoring local and regional outcomes to guide quality improvement initiatives.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Disease and Stroke Statistics—2013 Update: A Report From the American Heart Association
Go, A. S., Mozaffarian, D., Roger, V. L., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., Fox, C. S., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31828124ad · Cited by 5,292
Rehospitalizations among Patients in the Medicare Fee-for-Service Program
Jencks, S. F., Williams, M. V., & Coleman, E. A. (2009) · New England Journal of Medicine · doi:10.1056/nejmsa0803563 · Cited by 5,164 · cited 1×
“– 13 The 30-day and 1-year rates of repeat all-cause hospitalization for patients discharged for heart failure are approximately 25% and 70%, respectively.(14,15) One-half of these readmissions are due to recurrent heart failure.”
Sacco, R. L., Kasner, S. E., Broderick, J. P., Caplan, L. R., Connors, J. J. (., Culebras, A., Elkind, M. S. V., George, M. G., Hamdan, A. D., Higashida, R. T., et al. (2013) · Stroke · doi:10.1161/str.0b013e318296aeca · Cited by 3,569 · cited 2×
“MVARC recommends that the basic definitions, classifications, and levels of severity for stroke and transient ischemic attack after MV procedures generally conform to VARC-2 criteria (5) and be consistent with recent standards from the American Heart Association and American Stroke Association (19), as outlined in Tab…”
Third Universal Definition of Myocardial Infarction
Thygesen, K., Alpert, J. S., Jaffe, A. S., Simoons, M. L., Chaitman, B. R., & White, H. D. (2012) · Circulation · doi:10.1161/cir.0b013e31826e1058 · Cited by 2,985
Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
Adams, D. H., Popma, J. J., Reardon, M. J., Yakubov, S. J., Coselli, J. S., Deeb, G. M., Gleason, T. G., Buchbinder, M., Hermiller, J., Kleiman, N. S., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1400590 · Cited by 2,902
Self-citationDurack, D. T., Lukes, A. S., Bright, D. K., & Service, D. E. (1994) · The American Journal of Medicine · doi:10.1016/0002-9343(94)90143-0 · Cited by 2,572
Murphy, G. J., Reeves, B. C., Rogers, C. A., Rizvi, S. I. A., Culliford, L., & Angelini, G. D. (2007) · Circulation · doi:10.1161/circulationaha.107.698977 · Cited by 1,371 · cited 2×
“In addition, in recognition that blood transfusions have been strongly associated with adverse outcomes (45,46), the timing (e.”
Cited by
Généreux, P., Piazza, N., Alu, M. C., Nazif, T., Hahn, R. T., Pibarot, P., Bax, J. J., Leipsic, J. A., Blanke, P., Blackstone, E. H., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.02.038 · Cited by 1,313
Self-citationVARC-3 WRITING COMMITTEE, Généreux, P., Piazza, N., Alu, M. C., Nazif, T., Hahn, R. T., Pibarot, P., Bax, J. J., Leipsic, J. A., Blanke, P., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa799 · Cited by 915
Self-citationOutcome and undertreatment of mitral regurgitation: a community cohort study
Dziadzko, V., Clavel, M.-A., Dziadzko, M., Medina-Inojosa, J. R., Michelena, H., Maalouf, J., Nkomo, V., Thapa, P., & Enriquez-Sarano, M. (2018) · The Lancet · doi:10.1016/s0140-6736(18)30473-2 · Cited by 417
Yoon, S.-H., Whisenant, B. K., Bleiziffer, S., Delgado, V., Dhoble, A., Schofer, N., Eschenbach, L., Bansal, E., Murdoch, D. J., Ancona, M., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy590 · Cited by 383
Khan, J. M., Babaliaros, V. C., Greenbaum, A. B., Foerst, J. R., Yazdani, S., McCabe, J. M., Paone, G., Eng, M. H., Leshnower, B. G., Gleason, P. T., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.02.076 · Cited by 220
Guerrero, M., Vemulapalli, S., Xiang, Q., Wang, D. D., Eleid, M., Cabalka, A. K., Sandhu, G., Salinger, M., Russell, H., Greenbaum, A., et al. (2020) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.119.008425 · Cited by 210
Self-citationTransfemoral Transcatheter Tricuspid Valve Replacement With the EVOQUE System
Fam, N. P., von Bardeleben, R. S., Hensey, M., Kodali, S. K., Smith, R. L., Hausleiter, J., Ong, G., Boone, R., Ruf, T., George, I., et al. (2021) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2020.11.045 · Cited by 196
Self-citationTranscatheter Mitral Valve Therapy in the United States
Mack, M., Carroll, J. D., Thourani, V., Vemulapalli, S., Squiers, J., Manandhar, P., Deeb, G. M., Batchelor, W., Herrmann, H. C., Cohen, D. J., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.07.058 · Cited by 180
Messika-Zeitoun, D., Nickenig, G., Latib, A., Kuck, K.-H., Baldus, S., Schueler, R., La Canna, G., Agricola, E., Kreidel, F., Huntgeburth, M., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy424 · Cited by 165
Self-citation
Metadata
- Authors
- Stone, G. W., Adams, D. H., Abraham, W. T., Kappetein, A. P., Généreux, P., Vranckx, P., Mehran, R., Kuck, K.-H., Leon, M. B., Piazza, N., Head, S. J., Filippatos, G., & Vahanian, A. S.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-07-13
- Volume
- 36
- Issue
- 29
- Pages
- 1878-1891
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2120217728
- Cited by
- 248
- References
- 7
- FWCI
- 6.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.