Early hypo-attenuated leaflet thickening in balloon-expandable transcatheter aortic heart valves

Pache, Gregor, Schoechlin, Simon, Blanke, Philipp, Dorfs, Stephan, Jander, Nikolaus, Arepalli, Chesnal D., Gick, Michael, Buettner, Heinz-Joachim, Leipsic, Jonathon, Langer, Mathias, Neumann, Franz-Josef, Ruile, Philipp·2016·European Heart Journal

Abstract

AIMS: We sought to evaluate the frequency of early hypo-attenuated leaflet thickening (HALT) of the SAPIEN 3 transcatheter aortic valve (S3). METHODS AND RESULTS: Of 249 patients who had undergone S3 implantation, we studied 156 consecutive patients (85 women, median age 82.2 ± 5.5 years) by electrocardiogram (ECG)-triggered dual-source computed tomography angiography (CTA) after a median of 5 days post-transcatheter aortic valve implantation. The prosthesis was assessed for HALT. Apart from heparin, peri-interventional antithrombotic therapy consisted of single- (aspirin 29%) or dual- (aspirin plus clopidogrel 71%) antiplatelet therapy. Hypo-attenuated leaflet thickening was found in 16 patients [10.3% (95% confidence interval (CI) 5.5-15.0%)] of the patients. None of the baseline and procedural variables were significantly associated with HALT, nor did we find a significant association with the antithrombotic regimen, either peri-interventionally or at the time of CTA. Hypo-attenuated leaflet thickening was found in 6 of 45 patients with peri-interventional single-antiplatelet therapy and in 10 of 111 patients with dual-antiplatelet therapy at the time of intervention [13.3% (95% CI 3.4-23.3%) vs. 9% (95% CI 3.7-14.3%), P = 0.42]. Hypo-attenuated leaflet thickening was not associated with clinical symptoms, but a small, albeit significant difference in mean pressure gradient at the time of CTA (11.6 ± 3.4 vs. 14.9 ± 5.3 mmHg, P = 0.026). Full anticoagulation led to almost complete resolution of HALT in 13 patients with follow-up CTA. CONCLUSION: Irrespective of the antiplatelet regimen, early HALT occurred in 10% of our patients undergoing transcatheter aortic S3 implantation. Early HALT is clinically inapparent and reversible by full anticoagulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehv526

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Cited by

See all 292

Metadata

Authors
Pache, G., Schoechlin, S., Blanke, P., Dorfs, S., Jander, N., Arepalli, C. D., Gick, M., Buettner, H.-J., Leipsic, J., Langer, M., Neumann, F.-J., & Ruile, P.
Venue
European Heart Journal
Published
2015-10-07
Volume
37
Issue
28
Pages
2263-2271
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2254220616
Cited by
292
References
27
FWCI
25.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Early hypo-attenuated leaflet thickening in balloon-expandable transcatheter aortic heart valves. https://app.cochat.ai/papers/10.1093/eurheartj/ehv526
The paper
Pache, G., Schoechlin, S., Blanke, P., Dorfs, S., Jander, N., Arepalli, C. D., Gick, M., Buettner, H.-J., Leipsic, J., Langer, M., Neumann, F.-J., & Ruile, P. (2016). Early hypo-attenuated leaflet thickening in balloon-expandable transcatheter aortic heart valves. European Heart Journal. https://doi.org/10.1093/eurheartj/ehv526

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.