Daily remote monitoring of implantable cardioverter-defibrillators: insights from the pooled patient-level data from three randomized controlled trials (IN-TIME, ECOST, TRUST)
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Aims: Remote monitoring of implantable cardioverter-defibrillators may improve clinical outcome. A recent meta-analysis of three randomized controlled trials (TRUST, ECOST, IN-TIME) using a specific remote monitoring system with daily transmissions [Biotronik Home Monitoring (HM)] demonstrated improved survival. We performed a patient-level analysis to verify this result with appropriate time-to-event statistics and to investigate further clinical endpoints. Methods and results: Individual data of the TRUST, ECOST, and IN-TIME patients were pooled to calculate absolute risks of endpoints at 1-year follow-up for HM vs. conventional follow-up. All-cause mortality analysis involved all three trials (2405 patients). Other endpoints involved two trials, ECOST and IN-TIME (1078 patients), in which an independent blinded endpoint committee adjudicated the underlying causes of hospitalizations and deaths. The absolute risk of death at 1 year was reduced by 1.9% in the HM group (95% CI: 0.1–3.8%; P = 0.037), equivalent to a risk ratio of 0.62. Also the combined endpoint of all-cause mortality or hospitalization for worsening heart failure (WHF) was significantly reduced (by 5.6%; P = 0.007; risk ratio 0.64). The composite endpoint of all-cause mortality or cardiovascular (CV) hospitalization tended to be reduced by a similar degree (4.1%; P = 0.13; risk ratio 0.85) but without statistical significance. Conclusion: In a pooled analysis of the three trials, HM reduced all-cause mortality and the composite endpoint of all-cause mortality or WHF hospitalization. The similar magnitudes of absolute risk reductions for WHF and CV endpoints suggest that the benefit of HM is driven by the prevention of heart failure exacerbation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht150 · Cited by 2,809
MOND, H. G., & PROCLEMER, A. (2011) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2011.03150.x · Cited by 984 · cited 1×
“The rapidly growing number of patients with implantable cardioverter-defibrillators (ICDs) translates into increasing demand for their regular follow-up.(1,2) Remote ICD monitoring has been introduced to improve clinical efficiency by reducing the need for conventional in-office follow-up visits.”
BackgroundAn Empirical Transition Matrix for Non-homogeneous Markov Chains Based on Censored Observations
Johansen, R. (1978) · Cited by 844
Hindricks, G., Taborsky, M., Glikson, M., Heinrich, U., Schumacher, B., Katz, A., Brachmann, J., Lewalter, T., Goette, A., Block, M., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)61176-4 · Cited by 740 · cited 8×
“This is still an active area of research with inconsistent findings, as several nonrandomized clinical studies observed a considerable outcome benefit of remote ICD monitoring, including all-cause mortality,(10,14,15) and randomized trials mostly reported neutral results.(3,5,8,9,12) A meta-analysis of nine randomized…”
BackgroundMethodResultInfluentialSelf-citationVarma, N., Epstein, A. E., Irimpen, A., Schweikert, R., & Love, C. (2010) · Circulation · doi:10.1161/circulationaha.110.937409 · Cited by 594 · cited 4×
“TRUST (published in 2010) evaluated the safety of extended in-office follow-up intervals in the HM arm during 15 months after ICD implantation.(3) ECOST (2013) compared major CV adverse events combined with all-cause death during 27 months after ICD implantation.”
BackgroundMethodResultInfluentialSelf-citationThe CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) Trial
Crossley, G. H., Boyle, A., Vitense, H., Chang, Y., & Mead, R. H. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.012 · Cited by 526 · cited 1×
“This is still an active area of research with inconsistent findings, as several nonrandomized clinical studies observed a considerable outcome benefit of remote ICD monitoring, including all-cause mortality,(10,14,15) and randomized trials mostly reported neutral results.(3,5,8,9,12) A meta-analysis of nine randomized…”
ResultSaxon, L. A., Hayes, D. L., Gilliam, F. R., Heidenreich, P. A., Day, J., Seth, M., Meyer, T. E., Jones, P. W., & Boehmer, J. P. (2010) · Circulation · doi:10.1161/circulationaha.110.960633 · Cited by 515 · cited 1×
“Several non-randomized studies with other single or combined remote monitoring systems reported a larger improvement in clinical outcomes than our meta-analysis did.(10,14,15) In the context of remote monitoring of heart failure patients, it has been generally advised that the exact properties of different remote moni…”
ResultPacker, M. (2001) · Journal of Cardiac Failure · doi:10.1054/jcaf.2001.25652 · Cited by 396 · cited 2×
“Our observation that HM exerts less or no influence on CV events unrelated to heart failure may be the main reason why HM had a significant effect on the primary outcome in the IN-TIME trial only (on a composite clinical score specifically designed for patients with heart failure) but not in ECOST (on the incidence of…”
ResultA randomized trial of long-term remote monitoring of pacemaker recipients (The COMPAS trial)
Mabo, P., Victor, F., Bazin, P., Ahres, S., Babuty, D., Da Costa, A., Binet, D., & Daubert, J.-C. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr419 · Cited by 347
Landolina, M., Perego, G. B., Lunati, M., Curnis, A., Guenzati, G., Vicentini, A., Parati, G., Borghi, G., Zanaboni, P., Valsecchi, S., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.088971 · Cited by 344
Telemedicine and remote management of patients with heart failure
Anker, S. D., Koehler, F., & Abraham, W. T. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61229-4 · Cited by 343 · cited 2×
“This observation warrants closer examination and corroborates the suggestion that not all telemonitoring approaches in heart failure are the same in practice and in their resulting outcomes.(17) Hence, system specific analyses may be preferable to a global analysis combining systems with different operational characte…”
BackgroundSelf-citationGuedon-Moreau, L., Lacroix, D., Sadoul, N., Clementy, J., Kouakam, C., Hermida, J.-S., Aliot, E., Boursier, M., Bizeau, O., Kacet, S., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/ehs425 · Cited by 312 · cited 5×
“This is still an active area of research with inconsistent findings, as several nonrandomized clinical studies observed a considerable outcome benefit of remote ICD monitoring, including all-cause mortality,(10,14,15) and randomized trials mostly reported neutral results.(3,5,8,9,12) A meta-analysis of nine randomized…”
BackgroundMethodResultInfluentialSelf-citationFluid status telemedicine alerts for heart failure: a randomized controlled trial
Böhm, M., Drexler, H., Oswald, H., Rybak, K., Bosch, R., Butter, C., Klein, G., Gerritse, B., Monteiro, J., Israel, C., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw099 · Cited by 256 · cited 3×
“Both technology platform and work flow seem suited to achieve measurable benefit.(23) Our data suggest that multiparameter, automatic, daily remote monitoring may be superior to other platforms, but this remains speculative in the absence of a direct comparison of different remote monitoring systems.”
BackgroundMethodInfluentialRemote Monitoring of Implantable Cardioverter-Defibrillators
Parthiban, N., Esterman, A., Mahajan, R., Twomey, D. J., Pathak, R. K., Lau, D. H., Roberts-Thomson, K. C., Young, G. D., Sanders, P., & Ganesan, A. N. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.04.029 · Cited by 245 · cited 12×
“The confirmation of this earlier result is important, because the Kaplan-Meier method that we were able to use treats the inhomogeneous durations of the pooled studies (12–27 months) and cases of early study termination correctly.(13) In an attempt to explain why a significant survival benefit was observed in the IN-T…”
BackgroundMethodInfluentialVarma, N., Piccini, J. P., Snell, J., Fischer, A., Dalal, N., & Mittal, S. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.04.033 · Cited by 233
Self-citation2013 ESC Guidelines on Cardiac Pacing and Cardiac Resynchronization Therapy
(2014) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2013.11.003 · Cited by 196
Dubner, S., Auricchio, A., Steinberg, J. S., Vardas, P., Stone, P., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P., Breithardt, G., et al. (2012) · Europace · doi:10.1093/europace/eur303 · Cited by 179
Self-citationVarma, N., Michalski, J., Stambler, B., Pavri, B. B., & TRUST Investigators (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu066 · Cited by 98 · cited 4×
“The only notable difference between the trials was a higher attrition rate in TRUST (15.0% vs. 4.6% ECOST vs. 6.8% INTIME), which was also inhomogeneous (13.3% HM vs. 18.8% controls), suggesting better patient retention with the aid of HM.20 If the attrition concealed endpoints, the reported clinical benefit would be…”
BackgroundInfluentialSelf-citationHindricks, G., Elsner, C., Piorkowski, C., Táborský, M., Geller, J. C., Schumacher, B., BYTESNIK, J., & Kottkamp, H. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht207 · Cited by 84
Self-citationSimone, A. D., Leoni, L., Luzi, M., Amellone, C., Stabile, G., Rocca, V. L., Capucci, A., D'onofrio, A., Ammendola, E., Accardi, F., et al. (2015) · EP Europace · doi:10.1093/europace/euu318 · Cited by 77 · cited 1×
“Several non-randomized studies with other single or combined remote monitoring systems reported a larger improvement in clinical outcomes than our meta-analysis did.(10,14,15) In the context of remote monitoring of heart failure patients, it has been generally advised that the exact properties of different remote moni…”
ResultRemote follow-up and continuous remote monitoring, distinguished
Burri, H. (2013) · EP Europace · doi:10.1093/europace/eut071 · Cited by 38
Hess, P. L., Mi, X., Curtis, L. H., Wilkoff, B. L., Hegland, D. D., & Al‐Khatib, S. M. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2013.06.009 · Cited by 25 · cited 1×
“It has been generally shown that ICD patients adhere poorly to recommended follow-up schedules and that this non-adherence results in fewer regular follow-up visits and is correlated with worse outcome.(22) The clinical benefit we report from the present metaanalysis is compelling also because it was found against a c…”
ResultDevice Features for Managing Patients with Heart Failure
Varma, N., & Wilkoff, B. L. (2011) · Heart Failure Clinics · doi:10.1016/j.hfc.2010.12.005 · Cited by 20 · cited 1×
“benefit is driven by the prevention of WHF appears plausible for two reasons: (i) WHF decompensation requires several days or even weeks to develop, which offers time for automatic alerting and preemptive intervention;(11,12) and (ii) ICDs are capable of detecting and remotely alerting to several WHF prodromal symptom…”
MethodSelf-citation
Cited by
Heart Failure After Myocardial Infarction: Incidence and Predictors
Jenča, D., Melenovský, V., Stehlik, J., Staněk, V., Kettner, J., Kautzner, J., Adámková, V., & Wohlfahrt, P. (2021) · ESC Heart Failure · doi:10.1002/ehf2.13144 · Cited by 605
Chung, M. K., Patton, K. K., Lau, C.-P., Dal Forno, A. R. J., Al-Khatib, S. M., Arora, V., Birgersdotter-Green, U. M., Cha, Y.-M., Chung, E. H., Cronin, E. M., et al. (2023) · Heart Rhythm · doi:10.1016/j.hrthm.2023.03.1538 · Cited by 548
Self-citationJCS/JHFS 2025 Guideline on Diagnosis and Treatment of Heart Failure
Kitai, T., Kohsaka, S., Kato, T., Kato, E., Sato, K., Teramoto, K., Yaku, H., Akiyama, E., Ando, M., Izumi, C., et al. (2025) · Circulation Journal · doi:10.1253/circj.cj-25-0002 · Cited by 191
Metadata
- Authors
- Hindricks, G., Varma, N., Kacet, S., Lewalter, T., Søgaard, P., Guédon-Moreau, L., Proff, J., Gerds, T. A., Anker, S. D., & Torp-Pedersen, C.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2017-05-10
- Volume
- 38
- Issue
- 22
- Pages
- 1749-1755
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2612514758
- Cited by
- 160
- References
- 23
- FWCI
- 10.51
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.