The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
ISHNE/EHRA expert consensus on remote monitoring of cardiovascular implantable electronic devices (CIEDs)
Open accessAbstract
We are in the midst of a rapidly evolving era of technology-assisted medicine. The field of telemedicine provides the opportunity for highly individualized medical management in a way that has never been possible before. Evolving medical technologies using cardiac implantable devices (CIEDs) with capabilities for remote monitoring permit evaluation of multiple parameters of cardiovascular physiology and risk, including cardiac rhythm, device function, blood pressure values, the presence of myocardial ischaemia, and the degree of compensation of congestive heart failure. Cardiac risk, device status, and response to therapies can now be assessed with these electronic systems of detection and reporting. This document reflects the extensive experience from investigators and innovators around the world who are shaping the evolution of this rapidly expanding field, focusing in particular on implantable pacemakers (IPGs), implantable cardioverter-defibrillators (ICDs), devices for cardiac resynchronization therapy (CRT) (both, with and without defibrillation properties), loop recorders, and haemodynamic monitoring devices. This document covers the basic methodologies, guidelines for their use, experience with existing applications, and the legal and reimbursement aspects associated with their use. To adequately cover this important emerging topic, the International Society for Holter and Noninvasive Electrocardiology (ISHNE) and the European Heart Rhythm Association (EHRA) combined their expertise in this field. We hope that the development of this field can contribute to improve care of our cardiovascular patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Developed in collaboration with, European Heart Rhythm Association (EHRA), Heart Failure Association (HFA), and Heart Rhythm Society (HRS), societies, E. B. T. F., European Society of Emergency Medicine (EuSEM), European Federation of Internal Medicine (EFIM), European Union Geriatric Medicine Society (EUGMS), American Geriatrics Society (AGS), European Neurological Society (ENS), et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp298 · Cited by 2,040
Self-citationGlotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879
Glotzer, T. V., Hellkamp, A. S., Zimmerman, J., Sweeney, M. O., Yee, R., Marinchak, R., Cook, J., Paraschos, A., Love, J., Radoslovich, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000057981.70380.45 · Cited by 750
Varma, N., Epstein, A. E., Irimpen, A., Schweikert, R., & Love, C. (2010) · Circulation · doi:10.1161/circulationaha.110.937409 · Cited by 594
Self-citationSaxon, L. A., Hayes, D. L., Gilliam, F. R., Heidenreich, P. A., Day, J., Seth, M., Meyer, T. E., Jones, P. W., & Boehmer, J. P. (2010) · Circulation · doi:10.1161/circulationaha.110.960633 · Cited by 515
Self-citationHindricks, G., Piorkowski, C., Tanner, H., Kobza, R., Gerds-Li, J.-H., Carbucicchio, C., & Kottkamp, H. (2005) · Circulation · doi:10.1161/circulationaha.104.518837 · Cited by 506
BOTTO, G. L., PADELETTI, L., SANTINI, M., CAPUCCI, A., GULIZIA, M., ZOLEZZI, F., FAVALE, S., MOLON, G., RICCI, R., BIFFI, M., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01320.x · Cited by 380
Self-citationWilkoff, B. L., Auricchio, A., Brugada, J., Cowie, M., Ellenbogen, K. A., Gillis, A. M., Hayes, D. L., Howlett, J. G., Kautzner, J., Love, C. J., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.013 · Cited by 364
Self-citationIndications for the use of diagnostic implantable and external ECG loop recorders
Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, et al. (2009) · Europace · doi:10.1093/europace/eup097 · Cited by 362
Self-citationBrignole, M., Menozzi, C., Bartoletti, A., Giada, F., Lagi, A., Ungar, A., Ponassi, I., Mussi, C., Maggi, R., Re, G., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi647 · Cited by 332
Self-citation
Research works printed but not linked: 60
- Hayes, 2003, North American Society of Pacing and Electrophysiology. NASPE training requirements for cardiac implantable electronic devices: selection,implantation, and follow-up, Pacing Clin Electrophysiol, 26, 1556, 10.1046/j.1460-9592.2003.t01-1-00229.x · DOI
- Nacarelli, 2008, Task Force 6: training in specialized electrophysiology, cardiac pacing, and arrhythmia management, Heart Rhythm, 5, 332, 10.1016/j.hrthm.2008.01.001 · DOI
- Jung, 2008, Advances in remote monitoring of implantable pacemakers,cardioverter defibrillators and cardiac resynchronization therapy systems, J Interv Card Electrophysiol, 23, 73, 10.1007/s10840-008-9311-5 · DOI
- Burri, 2009, Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillators, Europace, 11, 701, 10.1093/europace/eup110 · DOI · Paper page
- Winters, 2001, North American Society of Electrophysiology and Pacing. Consensus statement on indications, guidelines for use, and recommendations for follow-up of implantable cardioverter-defibrillators, Pacing Clin Electrophysiol, 24, 262, 10.1046/j.1460-9592.2001.00262.x · DOI
- Schoenfeld, 2005, Sophisticated remote implantable cardioverter-defibrillator follow-up: a status report, Pacing Clin Electrophysiol, 28, 235, 10.1111/j.1540-8159.2005.09554.x · DOI
- Thenus, 2003, Home monitoring in ICD therapy: future perspectives, Europace, 5, 139, 10.1053/eupc.2002.0302 · DOI
- Stellbrink, 2001, Hartmann a potential applications of home monitoring in pacemaker therapy—a review with emphasis on atrial fibrillation and congestive heart failure, Prog Biomed Res, 2, 107
- Hauck, 2009, Home monitoring for early detection of implantable cardioverter-defibrillator failure, Clin Res Cardiol, 98, 19, 10.1007/s00392-008-0712-3 · DOI
- Res, 2006, The role of remote monitoring in the reduction of inappropriate implantable cardioverter defibrillator therapies, Clin Res Cardiol, 95, III17
- Lazarus, 2007, Remote, wireless, ambulatory monitoring of implantable pacemakers, cardioverter defibrillators, and cardiac resynchronization therapy systems: analysis of a worldwide database, Pacing Clin Electrophysiol, 30, S2
- Joseph, 2004, Remote interrogation and monitoring of implantable cardioverter defibrillators, J Interv Card Electrophysiol, 11, 161, 10.1023/B:JICE.0000042356.52369.89 · DOI
- Ricci, 2008, Home monitoring remote control of pacemaker and ICD patients in clinical practice. Impact on medical management and health care resource utilization, Europace, 10, 164, 10.1093/europace/eum289 · DOI · Paper page
- Przybylski, 2009, Technical and practical aspects of remote monitoring of implantable cardioverter-defibrillator patients in Poland—preliminary results, Kardiol Pol, 67, 505
- Fauchier, 2005, Potential cost savings by telemedicine-assisted longterm care of implantable cardioverter defibrillator recipients, Pacing Clin Electrophysiol, 28, S255, 10.1111/j.1540-8159.2005.00071.x · DOI
- Camm, 2010, Guidelines for the management of atrial fibrillation. The Task Force for the Management of Atrial Fibrillation of the European Society of Cardiology (ESC), Eur Heart J, 31, 2369
- Calkins, 2007, HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation, Europace, 9, 335, 10.1093/europace/eum120 · DOI · Paper page
- Jabaudon, 2004, Usefulness of ambulatory 7-day ECG monitoring for the detection of atrial fibrillation and flutter after acute stroke and transient ischemic attack, Stroke, 35, 1647, 10.1161/01.STR.0000131269.69502.d9 · DOI · Paper page
- Ziegler, 2006, Comparison of continuous versus intermittent monitoring of atrial arrhythmias, Heart Rhythm, 3, 1445, 10.1016/j.hrthm.2006.07.030 · DOI · Paper page
- Naccarelli, 2007, Ambulatory electrocardiographic monitoring, J Cardiovasc Electrophysiol, 18, 248, 10.1111/j.1540-8167.2006.00737.x · DOI
- Hindricks, 2010, Performance of a new leadless implantable cardiac monitor in detecting and quantifying atrial fibrillation, Circ Arrhythm Electrophysiol, 3, 141, 10.1161/CIRCEP.109.877852 · DOI · Paper page
- Kirchhof, 2007, Outcome parameters for trials in atrial fibrillation: executive summary, Eur Heart J, 28, 2803, 10.1093/eurheartj/ehm358 · DOI · Paper page
- Joshi, 2005, First experience with a Mobile Cardiac Outpatients Telemetry (MCOT) system for diagnosis and management of cardiac arrhythmia, Am J Cardiol, 95, 878, 10.1016/j.amjcard.2004.12.015 · DOI · Paper page
- Paruchuri, 2011, Clinical utility of a novel wireless implantable loop recorder in the evaluation of patients with unexplained syncope, Heart Rhythm, 8, 858, 10.1016/j.hrthm.2011.01.039 · DOI
- Huikuri, 2009, Prediction of fatal or near fatal cardiac arrhythmia events in patients with depressed left ventricular function after acute myocardial infarction. Results of the Cardiac Arrhythmias and Risk Stratification after Acute Myocardial Infarction (CARISMA) Study, Eur Heart J, 10, 109
- Spencker, 2009, A Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure, Europace, 11, 483, 10.1093/europace/eun350 · DOI
- Heidbuchel, 2008, Potential role of remote monitoring for scheduled and unscheduled evaluations of patients with an implantable defibrillator, Europace, 10, 351, 10.1093/europace/eun010 · DOI
- Elsner, 2006, A Prospective Multicenter Comparison Trial of home monitoring against regular follow-up in MADIT II, Comput Cardiol, 33, 241
- Crossley, 2008, The Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision (CONNECT) Trial, Am Heart J, 156, 840, 10.1016/j.ahj.2008.06.028 · DOI
- Neuzil, 2008, Early automatic remote detection of combined lead insulation defect and ICD damage, Europace, 10, 556, 10.1093/europace/eun009 · DOI
- Spencker, 2007, Severe pacemaker lead perforation detected by an automatic homemonitoring system, Eur Heart J, 28, 1432, 10.1093/eurheartj/ehl495 · DOI
- Ritter, 2006, Use of ‘IEGM online’ in ICD patients—early detection of inappropriate classified ventricular tachycardia via home monitoring, Clin Res Cardiol, 95, 368, 10.1007/s00392-006-0390-y · DOI
- Varma, 2005, Detection of atrial fibrillation by implanted devices with wireless data transmission capability, Pacing Clin Electrophysiol, 28, S133
- Varma, 2009, Remote monitoring for advisories: automatic early detection of silent lead failure, Pacing Clin Electrophysiol, 32, 525, 10.1111/j.1540-8159.2009.02314.x · DOI
- Varma, 2010, Automatic remote monitoring of ICD lead and generator performance: the TRUST trial, Circ Arrhythm Electrophysiol, 3, 428, 10.1161/CIRCEP.110.951962 · DOI · Paper page
- Hauser, 2006, Multicenter experience with failed and recalled implantable cardioverter-defibrillator pulse generators, Heart Rhythm, 3, 640, 10.1016/j.hrthm.2006.02.011 · DOI
- Maisel, 2006, Pacemaker and ICD generator reliability: meta-analysis of device registries, JAMA, 295, 1929, 10.1001/jama.295.16.1929 · DOI · Paper page
- Hauser, 2001, Unexpected ICD pulse generator failure due to electronic circuit damage caused by electrical overstress, Pacing Clin Electrophysiol, 24, 1046, 10.1046/j.1460-9592.2001.01046.x · DOI
- Varma, 2009, Prevalence of cancelled shock therapy and relationship to shock delivery in recipients of implantable cardioverter-defibrillators assessed by remote monitoring, Pacing Clin Electrophysiol, 32, S42
- Varma, 2011, Device features for heart failure, Heart Fail Clin North Am, 7, 215, 10.1016/j.hfc.2010.12.005 · DOI
- Mortara, 2009, Home telemonitoring in heart failure patients: the HHH study (Home or Hospital in Heart Failure), Eur Heart J, 11, 312
- Saxon, 2007, Remote active monitoring in patients with heart failure (RAPID-RF): design and rationale, J Cardiac Fail, 13, 241, 10.1016/j.cardfail.2006.12.004 · DOI
- Yu, 2005, Intrathoracic impedance monitoring in patients with heart failure: correlation with fluid status and feasibility of early warning preceding hospitalization, Circulation, 112, 841, 10.1161/CIRCULATIONAHA.104.492207 · DOI · Paper page
- Ritzema, 2007, Direct left atrial pressure monitoring in ambulatory heart failure patients: initial experience with a new permanent implantable device, Circulation, 116, 2952, 10.1161/CIRCULATIONAHA.107.702191 · DOI
- Abraham, 2011, Wireless pulmonary artery haemodynamic monitoring in chronic heart failure: a randomised controlled trial, Lancet, 377, 658, 10.1016/S0140-6736(11)60101-3 · DOI · Paper page
- Cheung, 2006, Newly detected atrial fibrillation following dual chamber pacemaker implantation, J Cardiovasc Electrophysiol, 17, 1323, 10.1111/j.1540-8167.2006.00648.x · DOI
- Hanke, 2009, Twenty-four-hour holter monitor follow-up does not provide accurate heart rhythm status after surgical atrial fibrillation ablation therapy, Circulation, 120, S177
- Halimi, 2008, Optimized post-operative surveillance of permanent pacemakers by home monitoring: the OEDIPE trial, Europace, 10, 1392, 10.1093/europace/eun250 · DOI
- Mabo, 2010, Home monitoring for pacemaker follow-up: results of randomized COMPAS trial, Europace, 12, i56
- Ricci, 2010, Long-term patient acceptance of and satisfaction with implanted device remote monitoring, Europace, 12, 674, 10.1093/europace/euq046 · DOI
- Simons, 2009, Alert tones are frequently inaudible among patients with implantable cardioverter-defibrillators, Pacing Clin Electrophysiol, 32, 1272, 10.1111/j.1540-8159.2009.02480.x · DOI
- Hauser, 2006, Multicenter experience with failed and recalled implantable cardioverter-defibrillator pulse generators, Heart Rhythm, 3, 640, 10.1016/j.hrthm.2006.02.011 · DOI
- Brugada, 2006, What evidence do we have to replace in-hospital implantable cardioverter defibrillator follow-up?, Clin Res Cardiol, 95, iii/3, 10.1007/s00392-006-1302-x · DOI
- Halperin, 2008, Pacemakers and implantable cardiac defibrillators: software radio attacks and zero-power defenses, 10.1109/SP.2008.31 · DOI · Paper page
- Guédon-Moreau, 2010, Contributions of remote monitoring to the follow-up of implantable cardioverter–defibrillator leads under advisory, Eur Heart J, 31, 2246, 10.1093/eurheartj/ehq203 · DOI
- Sticherling, 2009, Remote monitoring of cardiovascular implantable electronic devices. Prerequisite or luxury?, Swiss Med Wkly, 139, 596, 10.4414/smw.2009.12667 · DOI
- Neumann, 2010, Medicare and medical technology—the growing demand for relevant outcomes, N Engl J Med, 362, 5, 10.1056/NEJMp0912062 · DOI
- Vinck, 2010, Remote Monitoring for Patients with Implanted Defibrillators
- Klersy, 2009, A meta-analysis of remote monitoring of heart failure patients, J Am Coll Cardiol, 54, 1683, 10.1016/j.jacc.2009.08.017 · DOI · Paper page
- Trueman, 2010, Coverage with evidence development: applications and issues, Int J Technol Assess Health Care, 26, 179, 10.1017/S0266462309990882 · DOI
Cited by
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,489
Self-citationTracy, C. M., Epstein, A. E., Darbar, D., DiMarco, J. P., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P. E., Link, M. S., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.007 · Cited by 732
Slotwiner, D., Varma, N., Akar, J. G., Annas, G., Beardsall, M., Fogel, R. I., Galizio, N. O., Glotzer, T. V., Leahy, R. A., Love, C. J., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.05.008 · Cited by 532
Self-citationTracy, C. M., Epstein, A. E., Darbar, D., DiMarco, J. P., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P. E., Link, M. S., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.009 · Cited by 413
Tracy, C. M., Epstein, A. E., Darbar, D., DiMarco, J. P., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P. E., Link, M. S., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182618569 · Cited by 369
Metadata
- Authors
- Dubner, S., Auricchio, A., Steinberg, J. S., Vardas, P., Stone, P., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P., Breithardt, G., Zareba, W., Schuger, C., Aktas, M. K., Chudzik, M., Mittal, S., Varma, N., reviewers:, D., Israel (Germany), C., Padeletti (Italy), L., & Brignole (Italy), M.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-01-09
- Volume
- 14
- Issue
- 2
- Pages
- 278-293
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2150293516
- Cited by
- 179
- References
- 17
- FWCI
- 16.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ISHNE/EHRA expert consensus on remote monitoring of cardiovascular implantable electronic devices (CIEDs). https://app.cochat.ai/papers/10.1093/europace/eur303
- The paper
- Dubner, S., Auricchio, A., Steinberg, J. S., Vardas, P., Stone, P., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P., Breithardt, G., Zareba, W., Schuger, C., Aktas, M. K., Chudzik, M., Mittal, S., Varma, N., reviewers:, D., Israel (Germany), C., Padeletti (Italy), L., & Brignole (Italy), M. (2012). ISHNE/EHRA expert consensus on remote monitoring of cardiovascular implantable electronic devices (CIEDs). Europace. https://doi.org/10.1093/europace/eur303
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.