CoChat

Proceedings from the 2nd European Clinical Consensus Conference for device-based therapies for hypertension: state of the art and considerations for the future

Open access
Mahfoud, Felix, Schmieder, Roland E, Azizi, Michel, Pathak, Atul, Sievert, Horst, Tsioufis, Costas, Zeller, Thomas, Bertog, Stefan, Blankestijn, Peter J, Böhm, Michael, Burnier, Michel, Chatellier, Gilles, Durand Zaleski, Isabelle, Ewen, Sebastian, Grassi, Guido, Joner, Michael, Kjeldsen, Sverre E, Lobo, Melvin D, Lotan, Chaim, Lüscher, Thomas Felix, Parati, Gianfranco, Rossignol, Patrick, Ruilope, Luis, Sharif, Faisal, van Leeuwen, Evert, Volpe, Massimo, Windecker, Stephan, Witkowski, Adam, Wijns, William · 2017 · European Heart Journal
Cited by 122

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

High blood pressure (BP) is associated with adverse cardiovascular outcomes.1 A number of highly effective pharmacological therapies are available to treat hypertension but a substantial proportion of affected subjects remain inadequately controlled world-wide.2 There are many reasons for this situation, such as lack of access to treatments, physician inertia, inadequate dosing or combinations of treatments, suboptimal patient adherence to treatment, the use of interfering drugs or substance of abuse, the presence of undiagnosed secondary hypertension or of treatment-resistant hypertension. A large number of patients with hypertension are reluctant to take or adhere to pharmacotherapeutic regimens, because of interference with their daily lives, fear/experience of side effects, preferences for alternative medications, or other reasons.3 Treatment-resistant hypertension is commonly defined as BP level above target [office systolic BP (SBP) ≥140 mmHg or diastolic BP ≥90 mmHg] despite treatment with at least 3 antihypertensive medications in adequate doses, one of which should be a diuretic.4 The difficulty of treating hypertension, its high prevalence and severe consequences, and the absence of novel antihypertensive drugs on the horizon and the limitations of purely pharmacologic approaches have prompted the development of interventional approaches to provide complementary treatments. Several device-based approaches have been invented and subsequently tested; one which has received much positive as well as skeptical attention is catheter-based renal denervation (RDN).5 , 6 The method uses radiofrequency energy, alternatively ultrasound or chemical ablation, to disrupt renal nerves within the renal artery wall, thereby reducing sympathetic efferent and sensory afferent signalling to and from the kidneys.7 Historical observations showed that surgical sympathectomy can reduce BP as well as morbidity and mortality in patients with uncontrolled hypertension.8 Even though based on strong pathophysiological rationale,8 catheter-based RDN has not conclusively demonstrated its value for the treatment of resistant hypertension and its place in the therapeutic armamentarium remains uncertain.9–12 Other device-based approaches under investigation include the creation of a central iliac arteriovenous (AV)–anastomosis with a coupler, the stimulation of the carotid sinus, the ablation of the carotid body, and stent-based expansion of the carotid bulb.13 , 14 The multidisciplinary European Expert Group has previously published proceedings from their 2014 clinical consensus conference aiming at exploring the gaps in our knowledge about RDN and making recommendations of future randomized controlled trial design.6 A follow-up conference was convened in October 2016 to evaluate the position of device therapies for hypertension in the light of the latest clinical developments. This article presents the main conclusions from this event. We first present a survey of the changing clinical environment surrounding hypertension and its implications for clinical trials in the field. This is followed by an update on currently on-going clinical trials of device-based hypertension therapy and design considerations for further trials. Finally, needs and recommendations on the standardised assessment of emerging device therapies are discussed. Since the last consensus conference in 2014, several clinical trials have been published, which may influence how device-based therapies are viewed and investigated. The results raise questions around treatment regimens, BP targets, and the most appropriate way to measure BP. In patients with resistant hypertension, the option of adding a fourth antihypertensive drug has been investigated. The crossover trial PATHWAY-2 recently showed spironolactone to be superior to placebo as an add-on in patients with resistant hypertension who had been identified by renin profiling as potential responders to the therapy.15 Despite the positive results from PATHWAY-2, the Expert Group has discussed whether these results should prompt adding spironolactone as a fourth line treatment in the management of resistant hypertension to define a trial population for device-based proof of concept studies. In the PATHWAY-2 trial, patients were on a low-dose of bendroflumethiazide, a drug less effective than chlorthalidone or indapamide, which may have favoured the BP response to spironolactone; BP response was not analysed per aldosterone levels, body mass index or BP at baseline; the short time (6 weeks) of exposure to the maximum dose of spironolactone (50 mg/d) was insufficient for an accurate assessment of the long-term tolerability of this drug; and there are no data on efficacy and safety in patients with eGFR <45 mL/min/1.73 m2 since they were excluded from the trial. Moreover, in clinical practise spironolactone has a challenging tolerability profile with higher rates of intolerance than in PATHWAY-2, including gyneco

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehx215

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 122

Metadata

Authors
Mahfoud, F., Schmieder, R. E., Azizi, M., Pathak, A., Sievert, H., Tsioufis, C., Zeller, T., Bertog, S., Blankestijn, P. J., Böhm, M., Burnier, M., Chatellier, G., Durand Zaleski, I., Ewen, S., Grassi, G., Joner, M., Kjeldsen, S. E., Lobo, M. D., Lotan, C., Lüscher, T. F., Parati, G., Rossignol, P., Ruilope, L., Sharif, F., van Leeuwen, E., Volpe, M., Windecker, S., Witkowski, A., & Wijns, W.
Venue
European Heart Journal
Published
2017-05-05
Volume
38
Issue
44
Pages
3272-3281
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2611097218
Cited by
122
References
16
FWCI
12.14
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Proceedings from the 2nd European Clinical Consensus Conference for device-based therapies for hypertension: state of the art and considerations for the future. https://app.cochat.ai/papers/10.1093/eurheartj/ehx215
The paper
Mahfoud, F., Schmieder, R. E., Azizi, M., Pathak, A., Sievert, H., Tsioufis, C., Zeller, T., Bertog, S., Blankestijn, P. J., Böhm, M., Burnier, M., Chatellier, G., Durand Zaleski, I., Ewen, S., Grassi, G., Joner, M., Kjeldsen, S. E., Lobo, M. D., Lotan, C., . . . Wijns, W. (2017). Proceedings from the 2nd European Clinical Consensus Conference for device-based therapies for hypertension: state of the art and considerations for the future. European Heart Journal. https://doi.org/10.1093/eurheartj/ehx215

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.