Proceedings from the 2nd European Clinical Consensus Conference for device-based therapies for hypertension: state of the art and considerations for the future
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
High blood pressure (BP) is associated with adverse cardiovascular outcomes.1 A number of highly effective pharmacological therapies are available to treat hypertension but a substantial proportion of affected subjects remain inadequately controlled world-wide.2 There are many reasons for this situation, such as lack of access to treatments, physician inertia, inadequate dosing or combinations of treatments, suboptimal patient adherence to treatment, the use of interfering drugs or substance of abuse, the presence of undiagnosed secondary hypertension or of treatment-resistant hypertension. A large number of patients with hypertension are reluctant to take or adhere to pharmacotherapeutic regimens, because of interference with their daily lives, fear/experience of side effects, preferences for alternative medications, or other reasons.3 Treatment-resistant hypertension is commonly defined as BP level above target [office systolic BP (SBP) ≥140 mmHg or diastolic BP ≥90 mmHg] despite treatment with at least 3 antihypertensive medications in adequate doses, one of which should be a diuretic.4 The difficulty of treating hypertension, its high prevalence and severe consequences, and the absence of novel antihypertensive drugs on the horizon and the limitations of purely pharmacologic approaches have prompted the development of interventional approaches to provide complementary treatments. Several device-based approaches have been invented and subsequently tested; one which has received much positive as well as skeptical attention is catheter-based renal denervation (RDN).5 , 6 The method uses radiofrequency energy, alternatively ultrasound or chemical ablation, to disrupt renal nerves within the renal artery wall, thereby reducing sympathetic efferent and sensory afferent signalling to and from the kidneys.7 Historical observations showed that surgical sympathectomy can reduce BP as well as morbidity and mortality in patients with uncontrolled hypertension.8 Even though based on strong pathophysiological rationale,8 catheter-based RDN has not conclusively demonstrated its value for the treatment of resistant hypertension and its place in the therapeutic armamentarium remains uncertain.9–12 Other device-based approaches under investigation include the creation of a central iliac arteriovenous (AV)–anastomosis with a coupler, the stimulation of the carotid sinus, the ablation of the carotid body, and stent-based expansion of the carotid bulb.13 , 14 The multidisciplinary European Expert Group has previously published proceedings from their 2014 clinical consensus conference aiming at exploring the gaps in our knowledge about RDN and making recommendations of future randomized controlled trial design.6 A follow-up conference was convened in October 2016 to evaluate the position of device therapies for hypertension in the light of the latest clinical developments. This article presents the main conclusions from this event. We first present a survey of the changing clinical environment surrounding hypertension and its implications for clinical trials in the field. This is followed by an update on currently on-going clinical trials of device-based hypertension therapy and design considerations for further trials. Finally, needs and recommendations on the standardised assessment of emerging device therapies are discussed. Since the last consensus conference in 2014, several clinical trials have been published, which may influence how device-based therapies are viewed and investigated. The results raise questions around treatment regimens, BP targets, and the most appropriate way to measure BP. In patients with resistant hypertension, the option of adding a fourth antihypertensive drug has been investigated. The crossover trial PATHWAY-2 recently showed spironolactone to be superior to placebo as an add-on in patients with resistant hypertension who had been identified by renin profiling as potential responders to the therapy.15 Despite the positive results from PATHWAY-2, the Expert Group has discussed whether these results should prompt adding spironolactone as a fourth line treatment in the management of resistant hypertension to define a trial population for device-based proof of concept studies. In the PATHWAY-2 trial, patients were on a low-dose of bendroflumethiazide, a drug less effective than chlorthalidone or indapamide, which may have favoured the BP response to spironolactone; BP response was not analysed per aldosterone levels, body mass index or BP at baseline; the short time (6 weeks) of exposure to the maximum dose of spironolactone (50 mg/d) was insufficient for an accurate assessment of the long-term tolerability of this drug; and there are no data on efficacy and safety in patients with eGFR <45 mL/min/1.73 m2 since they were excluded from the trial. Moreover, in clinical practise spironolactone has a challenging tolerability profile with higher rates of intolerance than in PATHWAY-2, including gyneco
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Randomized Trial of Intensive versus Standard Blood-Pressure Control
The SPRINT Research Group (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1511939 · Cited by 6,325
Ettehad, D., Emdin, C. A., Kiran, A., Anderson, S. G., Callender, T., Emberson, J., Chalmers, J., Rodgers, A., & Rahimi, K. (2016) · The Lancet · doi:10.1016/s0140-6736(15)01225-8 · Cited by 3,755 · cited 1×
“4 and 10 mmHg in office BP as clinically meaningful, respectively.(29,30) These numbers have long been used in the power calculation for clinical studies and is comparable to what can typically be achieved with one antihypertensive drug.”
ResultEffects of intensive blood-pressure control in type 2 diabetes mellitus
(2010) · New England Journal of Medicine · doi:10.1056/nejmoa1001286 · Cited by 3,598
Mills, K. T., Bundy, J. D., Kelly, T. N., Reed, J. E., Kearney, P. M., Reynolds, K., Chen, J., & He, J. (2016) · Circulation · doi:10.1161/circulationaha.115.018912 · Cited by 3,531
A Controlled Trial of Renal Denervation for Resistant Hypertension
Bhatt, D. L., Kandzari, D. E., O'Neill, W. W., D'Agostino, R., Flack, J. M., Katzen, B. T., Leon, M. B., Liu, M., Mauri, L., Negoita, M., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1402670 · Cited by 2,186
Williams, B., MacDonald, T. M., Morant, S., Webb, D. J., Sever, P., McInnes, G., Ford, I., Cruickshank, J. K., Caulfield, M. J., Salsbury, J., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)00257-3 · Cited by 1,308
European Society of Hypertension practice guidelines for ambulatory blood pressure monitoring
Parati, G., Stergiou, G., O’Brien, E., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2014) · Journal of Hypertension · doi:10.1097/hjh.0000000000000221 · Cited by 1,021 · cited 2×
“Complementary to ABPM, home BP monitoring may favour BP control and patient adherence to treatment and is included in the most recent guidelines from the European Society for Hypertension.27 A number of electronic tools and smartphone apps are emerging to simplify the procedure for patients and its interpretation by p…”
BackgroundSelf-citationAssessment of blinding in clinical trials
Bang, H., Ni, L., & Davis, C. E. (2004) · Controlled Clinical Trials · doi:10.1016/j.cct.2003.10.016 · Cited by 682 · cited 1×
“A blinding index should be used to assess the efficacy of blinding in clinical device trials.(36) The index can be used for any blinded group, not only study subjects and researchers.”
MethodBaroreflex Activation Therapy Lowers Blood Pressure in Patients With Resistant Hypertension
Bisognano, J. D., Bakris, G., Nadim, M. K., Sanchez, L., Kroon, A. A., Schafer, J., de Leeuw, P. W., & Sica, D. A. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.06.008 · Cited by 600 · cited 1×
“Open label, non-randomized follow-up of the whole cohort reported that office systolic BP reduction of > 30 mmHg was sustained up to 53 months with no important safety concerns.(33,34) The Barostim NeoTM system has CE Mark approval for the treatment of RHTN and for heart failure.”
Background
Cited by
2018 ESC/ESH Guidelines for the management of arterial hypertension
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy339 · Cited by 10,286
Self-citationMancia, G., Kreutz, R., Brunström, M., Burnier, M., Grassi, G., Januszewicz, A., Muiesan, M. L., Tsioufis, K., Agabiti-Rosei, E., Algharably, E. A. E., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003480 · Cited by 3,473
Self-citationWilliams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001940 · Cited by 2,885
Self-citationKandzari, D. E., Böhm, M., Mahfoud, F., Townsend, R. R., Weber, M. A., Pocock, S., Tsioufis, K., Tousoulis, D., Choi, J. W., East, C., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(18)30951-6 · Cited by 793
Self-citationTownsend, R. R., Mahfoud, F., Kandzari, D. E., Kario, K., Pocock, S., Weber, M. A., Ewen, S., Tsioufis, K., Tousoulis, D., Sharp, A. S. P., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32281-x · Cited by 752
Self-citation
Metadata
- Authors
- Mahfoud, F., Schmieder, R. E., Azizi, M., Pathak, A., Sievert, H., Tsioufis, C., Zeller, T., Bertog, S., Blankestijn, P. J., Böhm, M., Burnier, M., Chatellier, G., Durand Zaleski, I., Ewen, S., Grassi, G., Joner, M., Kjeldsen, S. E., Lobo, M. D., Lotan, C., Lüscher, T. F., Parati, G., Rossignol, P., Ruilope, L., Sharif, F., van Leeuwen, E., Volpe, M., Windecker, S., Witkowski, A., & Wijns, W.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2017-05-05
- Volume
- 38
- Issue
- 44
- Pages
- 3272-3281
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2611097218
- Cited by
- 122
- References
- 16
- FWCI
- 12.14
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Proceedings from the 2nd European Clinical Consensus Conference for device-based therapies for hypertension: state of the art and considerations for the future. https://app.cochat.ai/papers/10.1093/eurheartj/ehx215
- The paper
- Mahfoud, F., Schmieder, R. E., Azizi, M., Pathak, A., Sievert, H., Tsioufis, C., Zeller, T., Bertog, S., Blankestijn, P. J., Böhm, M., Burnier, M., Chatellier, G., Durand Zaleski, I., Ewen, S., Grassi, G., Joner, M., Kjeldsen, S. E., Lobo, M. D., Lotan, C., . . . Wijns, W. (2017). Proceedings from the 2nd European Clinical Consensus Conference for device-based therapies for hypertension: state of the art and considerations for the future. European Heart Journal. https://doi.org/10.1093/eurheartj/ehx215
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.